A compact mechatronic system for 3D ultrasound guided prostate interventions.

PURPOSE Ultrasound imaging has improved the treatment of prostate cancer by producing increasingly higher quality images and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. However, it is critical that the needles be placed accurately within the prostate to deliver the therapy to the planned location and avoid complications of damaging surrounding tissues. METHODS The authors have developed a compact mechatronic system, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This system has been designed to allow guidance of a needle obliquely in 3D space into the prostate, thereby reducing pubic arch interference. The choice of needle trajectory and location in the prostate can be adjusted manually or with computer control. RESULTS To validate the system, a series of experiments were performed on phantoms. The 3D scan of the string phantom produced minimal geometric error, which was less than 0.4 mm. Needle guidance accuracy tests in agar prostate phantoms showed that the mean error of bead placement was less then 1.6 mm along parallel needle paths that were within 1.2 mm of the intended target and 1 degree from the preplanned trajectory. At oblique angles of up to 15 degrees relative to the probe axis, beads were placed to within 3.0 mm along a trajectory that were within 2.0 mm of the target with an angular error less than 2 degrees. CONCLUSIONS By combining 3D TRUS imaging system to a needle tracking linkage, this system should improve the physician's ability to target and accurately guide a needle to selected targets without the need for the computer to directly manipulate and insert the needle. This would be beneficial as the physician has complete control of the system and can safely maneuver the needle guide around obstacles such as previously placed needles.

[1]  Editorial: Prostate Specific Antigen , 1997 .

[2]  B R Thomadsen,et al.  Observations on rotating needle insertions using a brachytherapy robot , 2007, Physics in medicine and biology.

[3]  Aaron Fenster,et al.  A compact robotic apparatus and method for 3-D ultrasound guided prostate therapy , 2007, SPIE Medical Imaging.

[4]  C. Mettlin,et al.  Trends in prostate cancer care in the United States, 1974–1990: Observations from the patient care evaluation studies of the American college of surgeons commission on cancer , 1993, CA: a cancer journal for clinicians.

[5]  Rajnikant V. Patel,et al.  A Macro-Robot Manipulator for Medical Applications , 2006, 2006 IEEE International Conference on Systems, Man and Cybernetics.

[6]  J J W Lagendijk,et al.  Development of a tapping device: a new needle insertion method for prostate brachytherapy , 2006, Physics in medicine and biology.

[7]  Russell H. Taylor,et al.  A telerobotic assistant for laparoscopic surgery , 1995 .

[8]  D. Downey,et al.  Brachytherapy needle deflection evaluation and correction. , 2005, Medical physics.

[9]  J. Kettenbach,et al.  Robot-assisted biopsy using ultrasound guidance: initial results from in vitro tests , 2005, European Radiology.

[10]  Aaron Fenster,et al.  Design and evaluation of a 3D transrectal ultrasound prostate biopsy system. , 2008, Medical physics.

[11]  D. Downey,et al.  Three-dimensional ultrasound imaging , 1995, Medical Imaging.

[12]  Jay B. West,et al.  Predicting error in rigid-body point-based registration , 1998, IEEE Transactions on Medical Imaging.

[13]  I. Derweesh,et al.  Adverse effects of androgen deprivation therapy in prostate cancer: Current management issues , 2009, Indian journal of urology : IJU : journal of the Urological Society of India.

[14]  Wan Sing Ng,et al.  Hazard analysis of EUCLIDIAN: An image-guided robotic brachytherapy system , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  D. Stoianovici,et al.  Robotically assisted prostate brachytherapy with transrectal ultrasound guidance--Phantom experiments. , 2006, Brachytherapy.

[16]  John Strang,et al.  Robotic system for prostate brachytherapy. , 2007 .

[17]  J. Oesterling,et al.  Prostate Cancer Clinical Guidelines Panel Summary report on the management of clinically localized prostate cancer. The American Urological Association. , 1995, The Journal of urology.

[18]  Vythialingam Sathiaseelan,et al.  Intra-operative pubic arch interference during prostate seed brachytherapy in patients with CT-based pubic arch interference of < or =1cm. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  Aaron Fenster,et al.  A real-time biopsy needle segmentation technique using Hough transform. , 2003, Medical physics.

[20]  Daniel O Scharfstein,et al.  Utility of saturation biopsy to predict insignificant cancer at radical prostatectomy. , 2005, Urology.

[21]  S. Stokes,et al.  Transperineal ultrasound-guided radioactive seed implantation for organ-confined carcinoma of the prostate. , 1997, International journal of radiation oncology, biology, physics.

[22]  Aaron Fenster,et al.  Mechanically assisted 3D ultrasound guided prostate biopsy system. , 2008, Medical physics.

[23]  R. Kirby Pre-treatment staging of prostate cancer: recent advances and future prospects , 1997, Prostate Cancer and Prostatic Diseases.

[24]  T. Nakayama,et al.  Permanent prostate brachytherapy for Japanese men: Results from initial 100 patients with prostate cancer , 2007, International journal of urology : official journal of the Japanese Urological Association.

[25]  Nabil Zemiti,et al.  Design of an ultrasound-guided robotic brachytherapy needle-insertion system , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[26]  Gang Wan,et al.  Robot-assisted 3D-TRUS guided prostate brachytherapy: system integration and validation. , 2004, Medical physics.

[27]  M. Moallem,et al.  A Novel Manipulator for Percutaneous Needle Insertion: Design and Experimentation , 2009, IEEE/ASME Transactions on Mechatronics.

[28]  D. Downey,et al.  Needle and seed segmentation in intra-operative 3D ultrasound-guided prostate brachytherapy. , 2006, Ultrasonics.

[29]  Alexandru Patriciu,et al.  “MRI Stealth” robot for prostate interventions , 2007, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[30]  Peter Kazanzides,et al.  Robotic assistance for ultrasound-guided prostate brachytherapy , 2008, Medical Image Anal..

[31]  D. A. Christopher,et al.  A wall-less vessel phantom for Doppler ultrasound studies. , 1995, Ultrasound in medicine & biology.

[32]  Septimiu E. Salcudean,et al.  A robotic needle guide for prostate brachytherapy , 2008, 2008 IEEE International Conference on Robotics and Automation.

[33]  K. S. Arun,et al.  Least-Squares Fitting of Two 3-D Point Sets , 1987, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[34]  G. Johnson,et al.  In vivo small-animal imaging using micro-CT and digital subtraction angiography , 2008, Physics in medicine and biology.

[35]  S. Tong,et al.  A three-dimensional ultrasound prostate imaging system. , 1996, Ultrasound in medicine & biology.

[36]  Di Xiao,et al.  Ultrasound Guided Robotic Biopsy of the Prostate , 2006, Int. J. Humanoid Robotics.

[37]  M. Terris,et al.  Estimation of prostate cancer volume by transrectal ultrasound imaging. , 1992, The Journal of urology.

[38]  S Nag,et al.  Radioimmunoguided-intraoperative radiation therapy in colorectal carcinoma: a new technique to precisely define the clinical target volume. , 1999, International journal of radiation oncology, biology, physics.

[39]  D. Yan,et al.  Intraoperative optimization of needle placement and dwell times for conformal prostate brachytherapy. , 1995, International journal of radiation oncology, biology, physics.

[40]  P. Grimm,et al.  American Brachytherapy Society (ABS) recommendations for transperineal permanent brachytherapy of prostate cancer. , 1999, International journal of radiation oncology, biology, physics.

[41]  Sushil Beriwal,et al.  Overcoming pubic arch interference with free-hand needle placement in men undergoing prostate brachytherapy. , 2009, Brachytherapy.

[42]  Dan Stoianovici,et al.  AcuBot: a robot for radiological interventions , 2003, IEEE Trans. Robotics Autom..

[43]  T. Podder,et al.  Multi-channel robotic system for prostate brachytherapy , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.