An automated instrument for human STR identification: Design, characterization, and experimental validation

The microfluidic integration of an entire DNA analysis workflow on a fully integrated miniaturized instrument is reported using lab‐on‐a‐chip automation to perform DNA fingerprinting compatible with CODIS standard relevant to the forensic community. The instrument aims to improve the cost, duration, and ease of use to perform a “sample‐to‐profile” analysis with no need for human intervention. The present publication describes the operation of the three major components of the system: the electronic control components, the microfluidic cartridge and CE microchip, and the optical excitation/detection module. Experimental details are given to characterize the level of performance, stability, reliability, accuracy, and sensitivity of the prototype system. A typical temperature profile from a PCR amplification process and an electropherogram of a commercial size standard (GeneScan 500™, Applied Biosystems) separation are shown to assess the relevance of the instrument to forensic applications. Finally, we present a profile from an automated integrated run where lysed cells from a buccal swab were introduced in the system and no further human intervention was required to complete the analysis.

[1]  Robin H. Liu,et al.  Single-use, thermally actuated paraffin valves for microfluidic applications , 2004 .

[2]  Richard A Mathies,et al.  Multichannel PCR-CE microdevice for genetic analysis. , 2006, Analytical chemistry.

[3]  S. Brand,et al.  The Economic and Social Costs of Crime , 2000 .

[4]  Chong H. Ahn,et al.  Institute of Physics Publishing Journal of Micromechanics and Microengineering a Review of Microvalves , 2022 .

[5]  M. Yohda,et al.  Effects of linear polyacrylamide concentrations and applied voltages on the separation of oligonucleotides and DNA sequencing fragments by capillary electrophoresis. , 1994, Analytical chemistry.

[6]  Michael J. Little,et al.  Nanomolar derivatizations with 5-carboxyfluorescein succinimidyl ester for fluorescence detection in capillary electrophoresis , 1998 .

[7]  Richard A Mathies,et al.  Integrated sample cleanup-capillary electrophoresis microchip for high-performance short tandem repeat genetic analysis. , 2009, Analytical chemistry.

[8]  Peng Liu,et al.  Integrated portable polymerase chain reaction-capillary electrophoresis microsystem for rapid forensic short tandem repeat typing. , 2007, Analytical chemistry.

[9]  Chen Yu,et al.  A self-contained fully-enclosed microfluidic cartridge for lab on a chip , 2009, Biomedical microdevices.

[10]  Eugene Tan,et al.  Fast Multiplexed Polymerase Chain Reaction for Conventional and Microfluidic Short Tandem Repeat Analysis , 2009, Journal of forensic sciences.

[11]  Zhongqi Xu,et al.  Impact of reservoir potentials on the analyte behavior in microchip electrophoresis: Computer simulation and experimental validation for DNA fragments , 2005, Electrophoresis.

[12]  Michael G. Roper,et al.  A fully integrated microfluidic genetic analysis system with sample-in–answer-out capability , 2006, Proceedings of the National Academy of Sciences.

[13]  Poly‐N‐hydroxyethylacrylamide (polyDuramide™): A novel, hydrophilic, self‐coating polymer matrix for DNA sequencing by capillary electrophoresis , 2002, Electrophoresis.

[14]  Robin H. Liu,et al.  Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection. , 2004, Analytical chemistry.

[15]  Eun Sok Kim,et al.  Microfluidic motion generation with acoustic waves , 1998 .

[16]  A Manz,et al.  Miniaturised nucleic acid analysis. , 2004, Lab on a chip.

[17]  Jerome P Ferrance,et al.  An integrated microfluidic device for DNA purification and PCR amplification of STR fragments. , 2010, Forensic science international. Genetics.

[18]  Numrin Thaitrong,et al.  Polymerase chain reaction-capillary electrophoresis genetic analysis microdevice with in-line affinity capture sample injection. , 2009, Analytical chemistry.

[19]  Brian McKenna,et al.  A high‐performance multilane microdevice system designed for the DNA forensics laboratory , 2004, Electrophoresis.

[20]  Metin Muradoglu,et al.  Mixing of miscible liquids in gas-segmented serpentine channels , 2009 .

[21]  Robert Burger,et al.  High‐speed analysis of multiplexed short tandem repeats with an electrophoretic microdevice , 2002, Electrophoresis.

[22]  John M. Butler,et al.  Forensic DNA Typing: Biology, Technology, and Genetics of STR Markers , 2001 .

[23]  R. Pal,et al.  Phase change microvalve for integrated devices. , 2004, Analytical chemistry.