Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint

The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint.

[1]  K Gyo,et al.  Measurement of the ossicular vibration ratio in human temporal bones by use of a video measuring system. , 1987, Acta oto-laryngologica.

[2]  G. Isaacson,et al.  Ossiculoplasty in Young Children With the Applebaum Incudostapedial Joint Prosthesis , 1999, The Laryngoscope.

[3]  W. F. Decraemer,et al.  MEASUREMENT, VISUALIZATION AND QUANTITATIVE ANALYSIS OF COMPLETE THREE-DIMENSIONAL KINEMATICAL DATA SETS OF HUMAN AND CAT MIDDLE EAR , 2004 .

[4]  George Herrmann,et al.  MECHANICS OF BONE FRACTURE , 1972 .

[5]  W. T. Peake,et al.  Experiments in Hearing , 1963 .

[6]  R. Vishwakarma,et al.  Incudostapedial joint arthroplasty using temporalis fascia/perichondrium ties. , 2009, American journal of otolaryngology.

[7]  E. Abel,et al.  Movements of the intact and reconstructed ossicular chain during changes in static pressure , 2004, Acta oto-laryngologica.

[8]  G. Békésy,et al.  Experiments in Hearing , 1963 .

[9]  W. F. Decraemer,et al.  New insights into vibration of the middle ear , 2000 .

[10]  Tao Cheng,et al.  Mechanical properties of anterior malleolar ligament from experimental measurement and material modeling analysis , 2008, Biomechanics and modeling in mechanobiology.

[11]  W. Robert J. Funnell,et al.  On the Coupling Between the Incus and the Stapes in the Cat , 2005, Journal of the Association for Research in Otolaryngology.

[12]  W. Stupka Zur Histologic und Pathogenese einiger schwererer Fehlbildungen der Nase1 , 1934 .

[13]  S. Khanna,et al.  Malleus vibration modelled as rigid body motion. , 1995, Acta oto-rhino-laryngologica Belgica.

[14]  R. Ogden Non-Linear Elastic Deformations , 1984 .

[15]  V. Ribitsch,et al.  [Viscosity of synovial fluid and possible artificial lubricants (author's transl)]. , 1980, Acta medica Austriaca.

[16]  C. Karmody,et al.  The Incudostapedial Articulation: New Concepts , 2009, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[17]  Rong Z. Gan,et al.  Modeling of Sound Transmission from Ear Canal to Cochlea , 2007, Annals of Biomedical Engineering.

[18]  Hongbing Lu,et al.  Measurement of young's modulus of human tympanic membrane at high strain rates. , 2009, Journal of biomechanical engineering.

[19]  Rong Z. Gan,et al.  Viscoelastic Properties of Human Tympanic Membrane , 2007, Annals of Biomedical Engineering.

[20]  M. M. Paparella Three-Dimensional Virtual Model of the Human Temporal Bone: A Stand-Alone, Downloadable Teaching Tool , 2007 .

[21]  Q. Sun,et al.  Three-Dimensional Finite Element Modeling of Human Ear for Sound Transmission , 2004, Annals of Biomedical Engineering.

[22]  S. Komune,et al.  Histochemical characterization of the rat ossicular joint cartilage with a special reference to stapediovestibular joint , 2005 .

[23]  Tao Cheng,et al.  Finite-element analysis of middle-ear pressure effects on static and dynamic behavior of human ear. , 2007, The Journal of the Acoustical Society of America.

[24]  L. Greenberg,et al.  Incudostapedial joint disarticulation. , 1972, Archives of otolaryngology.

[25]  C. G. Lyons,et al.  Viscoelastic properties of passive skeletal muscle in compression: stress-relaxation behaviour and constitutive modelling. , 2008, Journal of biomechanics.

[26]  Sunil Puria,et al.  Ossicular resonance modes of the human middle ear for bone and air conduction. , 2009, The Journal of the Acoustical Society of America.

[27]  James S. Davidson,et al.  Three-Dimensional Finite Element Models of the Human Pubic Symphysis with Viscohyperelastic Soft Tissues , 2006, Annals of Biomedical Engineering.

[28]  A. Hagiwara,et al.  Involvement of the incudostapedial joint anomaly in conductive deafness , 2008, Acta oto-laryngologica.

[29]  E. Samįm,et al.  The impact of fixated glass ionomer cement and springy cortical bone incudostapedial joint reconstruction on hearing results , 2009, Acta oto-laryngologica.

[30]  Patrick J. Prendergast,et al.  Vibro-Acoustic Modelling of the Outer and Middle Ear Using the Finite-Element Method , 1999, Audiology and Neurotology.

[31]  Joris A. M. Soons,et al.  Elasticity modulus of rabbit middle ear ossicles determined by a novel micro-indentation technique , 2010, Hearing Research.

[32]  Rong Z Gan,et al.  Multifield coupled finite element analysis for sound transmission in otitis media with effusion. , 2007, The Journal of the Acoustical Society of America.

[33]  Albrecht Eiber Mechanical Modeling and Dynamical Behavior of the Human Middle Ear , 1999, Audiology and Neurotology.