An Inchworm-like Locomotion Mechanism Based on Magnetic Actuator for Active Capsule Endoscope

Locomotion mechanism is a necessity for development of an active capsule endoscope. In this paper, we propose an inchworm-like locomotion mechanism, which is composed of a permanent magnet, a plunger, a solenoid and a cone-shaped polymer. When an alternating current is applied to the solenoid, the magnet will make a reciprocating movement under the electromagnetic force. With the friction difference produced by the polymer, the actuator could propel itself forward on a 2D surface. The working principle and kinetic model of the mechanism are analyzed. A prototype with a size of Phi12*37 mm were fabricated to study the feasibility of the mechanism. Experiments were carried out on the surfaces of various frictional coefficients. The results show that the actuator works more efficiently on the surface of the glass than on the paper, because the polymer has better clamping effect on the former. The velocity changes with the frequency and amplitude of the current. The mechanism consumes a low power and it can work under a relatively low voltage (less than 20 V). It has the potential for actuation of an active capsule endoscope

[1]  William K. Durfee,et al.  IEEE/RSJ/GI International Conference on Intelligent Robots and Systems , 1994 .

[2]  M.Q.-H. Meng,et al.  Study of Frictional Properties of the Small Intestine for Design of Active Capsule Endoscope , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[3]  Tao Mei,et al.  Wireless robotic capsule endoscopy: state-of-the-art and challenges , 2004, Fifth World Congress on Intelligent Control and Automation (IEEE Cat. No.04EX788).

[4]  P. Dario,et al.  Locomotion of a legged capsule in the gastrointestinal tract: theoretical study and preliminary technological results , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  H TILLANDER,et al.  Magnetic guidance of a catheter with articulated steel tip. , 1951, Acta radiologica.

[6]  M.Q.-H. Meng,et al.  Physiological Factors of the Small Intestine in Design of Active Capsule Endoscopy , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[7]  Byungkyu Kim,et al.  Design and fabrication of a locomotive mechanism for capsule-type endoscopes using shape memory alloys (SMAs) , 2005, IEEE/ASME Transactions on Mechatronics.

[8]  Sukho Park,et al.  An earthworm-like locomotive mechanism for capsule endoscopes , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[9]  Soohyun Kim,et al.  Magnetic Impact Actuator for Robotic Endoscope , 2001 .

[10]  P. Swain,et al.  Wireless capsule endoscopy. , 2002, The Israel Medical Association journal : IMAJ.

[11]  Joel W. Burdick,et al.  Biomechanical modeling of the small intestine as required for the design and operation of a robotic endoscope , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[12]  K. Ikuta,et al.  The Application Of Micro/miniature Mechatronics Abstract Medical Robotics , 2002, IEEE International Workshop on Intelligent Robots.

[14]  Koji Ikuta,et al.  Shape memory alloy servo actuator system with electric resistance feedback and application for active endoscope , 1988, Proceedings. 1988 IEEE International Conference on Robotics and Automation.

[15]  Yong Chen,et al.  Wireless drive and control of a swimming microrobot , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[16]  Paolo Dario,et al.  Analysis and development of locomotion devices for the gastrointestinal tract , 2002, IEEE Transactions on Biomedical Engineering.

[17]  K. Arai,et al.  Fabrication of magnetic actuator for use in capsule endoscope , 2003, Digest of INTERMAG 2003. International Magnetics Conference (Cat. No.03CH37401).

[18]  T. Fukuda,et al.  Giant magnetostrictive alloy (GMA) applications to micro mobile robot as a micro actuator without power supply cables , 1991, [1991] Proceedings. IEEE Micro Electro Mechanical Systems.