Development of a cascade impactor system for sampling 0. 02 to 20 micron diameter particles. Final report
暂无分享,去创建一个
An improved cascade impactor sampling train was constructed to size particles emitted from electric power utility generating stations. The new sampling train components were designed to accompany the UW Mark 3-4 Source Test Cascade Impactor. The capability of this instrumentation to perform in-stack particulate sizing in the 0.02 to 20 micron diameter range has been demonstrated. Source tests were conducted at the coal-fired power boiler at the J.E. Corette Power Plant, Billings, Montana; the Nucla Power Plant, Nucla, Colorado; and the University of Washington Power Plant, Seattle, Washington.