Analysis of lateral flow biodetectors: competitive format.

Lateral flow (LF) biodetectors facilitate low-cost, rapid identification of various analytes. The LF cell consists of a porous membrane containing immobilized ligands at various locations. Through the action of capillary forces, a mixture of sample and reporter particles is transported to the ligand sites, where the target analytes and the reporters bind to the immobilized ligand. The concentration of the reporters is measured with a scanner. A mathematical model for two different competitive assays is constructed and used to study the performance of LF devices under various operating conditions. The model predicts the signal magnitude as a function of target analyte, reporter, and ligand concentrations, reaction rate constants, and flow rate. The predictions are compared and qualitatively agree with experimental data. The model provides insights into various experimental observations. Furthermore, the model can be used to optimize the performance of LF devices and to inexpensively and rapidly test the system under various operating conditions.

[1]  H. Weetall,et al.  A SIMPLE ASSAY FOR 2,4-DICHLOROPHENOXYACETIC ACID USING COATED TEST-STRIPS , 2002 .

[2]  S. Kapil,et al.  Development, Evaluation, and Application of Lateral-Flow Immunoassay (Immunochromatography) for Detection of Rotavirus in Bovine Fecal Samples , 2002, Clinical and Vaccine Immunology.

[3]  Assessment of the performance of a rapid, lateral flow assay for the detection of antibodies to HIV. , 2001 .

[4]  J Carlsson,et al.  Quantitative detection in the attomole range for immunochromatographic tests by means of a flatbed scanner. , 2001, Analytical biochemistry.

[5]  R A Durst,et al.  Detection of Cryptosporidium parvum using oligonucleotide-tagged liposomes in a competitive assay format. , 2001, Analytical chemistry.

[6]  Farid E Ahmed,et al.  Detection of genetically modified organisms in foods. , 2002, Trends in biotechnology.

[7]  Zora Modrusan,et al.  Rapid Solid-Phase Immunoassay for Detection of Methicillin-Resistant Staphylococcus aureus Using Cycling Probe Technology , 2000, Journal of Clinical Microbiology.

[8]  R A Durst,et al.  Liposome dehydration on nitrocellulose and its application in a biotin immunoassay. , 1999, Analytical biochemistry.

[9]  Young Min Kim,et al.  Development of an ultrarapid one-step fluorescence immunochromatographic assay system for the quantification of microcystins. , 2003, Environmental science & technology.

[10]  Mats Nilsson,et al.  Lateral-flow and up-converting phosphor reporters to detect single-stranded nucleic acids in a sandwich-hybridization assay. , 2003, Analytical biochemistry.

[11]  J. Ho,et al.  A strip liposome immunoassay for aflatoxin B1. , 2002, Analytical chemistry.

[12]  H. Kamiya,et al.  Development of oligonucleotide lateral-flow immunoassay for multi-parameter detection. , 2001, Journal of immunological methods.

[13]  N. A. Mufti,et al.  Upconverting phosphor reporters in immunochromatographic assays. , 2001, Analytical biochemistry.

[14]  H Tanke,et al.  Use of up-converting phosphor reporters in lateral-flow assays to detect specific nucleic acid sequences: a rapid, sensitive DNA test to identify human papillomavirus type 16 infection. , 2001, Clinical chemistry.

[15]  C. Moore,et al.  Comparison of point-of-collection screening of drugs of abuse in oral fluid with a laboratory-based urine screen. , 2001, Forensic science international.

[16]  S. Brannan,et al.  Blind trials of an onsite saliva drug test for marijuana and opiates. , 2001, Journal of forensic sciences.

[17]  C. Yersin,et al.  Lateral-Flow Assay for Rapid Serodiagnosis of Human Leptospirosis , 2001, Clinical Diagnostic Laboratory Immunology.

[18]  J. Burton,et al.  Detection of analytes by immunoassay using up-converting phosphor technology. , 2001, Analytical biochemistry.

[19]  J. Carlsson,et al.  Chromatographic performance of a thin microporous bed of nitrocellulose. , 2001, Journal of chromatography. B, Biomedical sciences and applications.

[20]  C. Quach,et al.  QuickVue Influenza Test for Rapid Detection of Influenza A and B Viruses in a Pediatric Population , 2002, Clinical and Vaccine Immunology.

[21]  Shizhi Qian,et al.  A mathematical model of lateral flow bioreactions applied to sandwich assays. , 2003, Analytical biochemistry.

[22]  M. Beach,et al.  Evaluation of Three Commercial Assays for Detection of Giardia and Cryptosporidium Organisms in Fecal Specimens , 2003, Journal of Clinical Microbiology.

[23]  P. Roggero,et al.  HOST RANGE, SEED TRANSMISSION AND DETECTION BY ELISA AND LATERAL FLOW OF AN ITALIAN ISOLATE OF PEPINO MOSAIC VIRUS , 2002 .