Complications Associated with Locking Plate of Proximal Humerus Fractures

Proximal humerus fractures constitute a significant percentage of fragility fractures. The growing use of locking plate has helped treat this problem, but at the same time has brought about complications. Past systematic reviews have documented these complications, however a large number of recent studies have been published since, reporting their own complication rates with different techniques. This study reviews the current complications associated with locking plate of proximal humerus fractures as well as methods to reduce them. A systematic review, following the PRISMA guidelines, was conducted in November 2013 and repeated in March 2015, using PubMed, Scopus, and Cochrane databases, to evaluate locking plate fixation (and complications) of traumatic proximal humerus fractures. Inclusion criteria included adults (>18 years), minimum of 12-month postoperative followup, articles within the last 5 years, and studies with >10 participants. Exclusion criteria included pathologic fractures, cadaveric studies, and nonhuman subjects. Eligible studies were graded using a quality scoring system. Articles with a minimum of 7/10 score were included and assessed regarding their level of evidence per the Journal of Bone and Joint Surgery and Centre for Evidence-Based Medicine guidelines. The initial query identified 51,206 articles from multiple databases. These records were thoroughly screened and resulted in 57 articles, consisting of seven Level 1, three Level 2, 10 Level 3, and 37 Level 4 studies, totaling 3422 proximal humerus fractures treated with locking plates. Intraarticular screw penetration was the most reported complication (9.5%), followed by varus collapse (6.8%), subacromial impingement (5.0%), avascular necrosis (4.6%), adhesive capsulitis (4.0%), nonunion (1.5%), and deep infection (1.4%). Reoperation occurred at a rate of 13.8%. Collapse at the fracture site contributed to a majority of the implant-related complications, which in turn were the main reasons for reoperation. The authors of these studies discussed different techniques that could be used to address these issues. Expanding use of locking plate in the proximal humerus fractures leads to improvements and advancements in surgical technique. Further research is necessary to outline indications to decrease complications, further.

[1]  Yingze Zhang,et al.  Meta-analysis suggests that reverse shoulder arthroplasty in proximal humerus fractures is a better option than hemiarthroplasty in the elderly , 2016, International Orthopaedics.

[2]  M. Rosenwasser,et al.  The Epidemiology of Upper Extremity Fractures in the United States, 2009 , 2015, Journal of orthopaedic trauma.

[3]  C. Theisen,et al.  Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate. , 2015, Journal of shoulder and elbow surgery.

[4]  A. Rangan,et al.  The ProFHER (PROximal Fracture of the Humerus: Evaluation by Randomisation) trial - a pragmatic multicentre randomised controlled trial evaluating the clinical effectiveness and cost-effectiveness of surgical compared with non-surgical treatment for proximal fracture of the humerus in adults. , 2015, Health technology assessment.

[5]  C. Ahmad,et al.  Reverse Shoulder Arthroplasty for the Management of Proximal Humerus Fractures , 2015, The Journal of the American Academy of Orthopaedic Surgeons.

[6]  Xing Wu,et al.  Advantage of Minimally Invasive Lateral Approach Relative to Conventional Deltopectoral Approach for Treatment of Proximal Humerus Fractures , 2015, Medical science monitor : international medical journal of experimental and clinical research.

[7]  V. Lepola,et al.  Epidemiology of proximal humerus fractures , 2015, Archives of Osteoporosis.

[8]  Vijay Sharma,et al.  Management of Proximal Humeral Fractures with Proximal Humerus Locking Plate—A Prospective Study: 以肱骨近端鎖定鋼板治療近端肱骨骨折—個前瞻性的研究 , 2014 .

[9]  Sang-Jin Shin,et al.  Minimally invasive plate osteosynthesis for proximal humeral fractures: clinical and radiologic outcomes according to fracture type. , 2014, Journal of shoulder and elbow surgery.

[10]  Wolf Mutschler,et al.  Long-term functional outcomes (median 10 years) after locked plating for displaced fractures of the proximal humerus. , 2014, Journal of shoulder and elbow surgery.

[11]  J. Goldhahn,et al.  The Influence of Local Bone Density on the Outcome of One Hundred and Fifty Proximal Humeral Fractures Treated with a Locking Plate. , 2014, The Journal of bone and joint surgery. American volume.

[12]  Shuhua Yang,et al.  Minimally invasive plate osteosynthesis with a locking compression plate is superior to open reduction and internal fixation in the management of the proximal humerus fractures , 2014, BMC Musculoskeletal Disorders.

[13]  D. Lorich,et al.  The Impact of Preoperative Coronal Plane Deformity on Proximal Humerus Fixation With Endosteal Augmentation , 2014, Journal of orthopaedic trauma.

[14]  S. Ruchholtz,et al.  Deltoid-split or Deltopectoral Approaches for the Treatment of Displaced Proximal Humeral Fractures? , 2014, Clinical orthopaedics and related research.

[15]  H. Prasad,et al.  Outcome of Locking Compression Plating for Proximal Humeral Fractures: A Prospective Study , 2014, Journal of orthopaedic surgery.

[16]  L. Frich,et al.  Bone properties of the humeral head and resistance to screw cutout , 2014, International journal of shoulder surgery.

[17]  Yanxi Chen,et al.  Computer-assisted preoperative planning for proximal humeral fractures by minimally invasive plate osteosynthesis. , 2014, Chinese medical journal.

[18]  D. Kohn,et al.  Treatment for displaced proximal humerus fractures: comparison of interlocking plate fixation versus minimal invasive techniques , 2014, European Journal of Orthopaedic Surgery & Traumatology.

[19]  A. Pellegrini,et al.  Can the osteosynthesis with locking plates be a better treatment for unstable fractures of the proximal humerus? , 2014, MUSCULOSKELETAL SURGERY.

[20]  K. Dietz,et al.  Complication rates and outcomes stratified by treatment modalities in proximal humeral fractures: a systematic literature review from 1970–2009 , 2013, Patient Safety in Surgery.

[21]  J. Vroemen,et al.  Proximal fractures of the humerus in patients older than 75 years of age: should we consider operative treatment? , 2013, Journal of Orthopaedics and Traumatology.

[22]  R. Page,et al.  Fixed‐angle locking proximal humerus plate: an evaluation of functional results and implant‐related outcomes , 2013, ANZ journal of surgery.

[23]  R. Sahu Minimally invasive percutaneous plate osteosynthesis for the treatment of proximal humerus fractures in osteoporotic patients with Philos plate , 2013 .

[24]  Christian Gerber,et al.  Locking plate fixation of fractures of the proximal humerus: analysis of complications, revision strategies and outcome. , 2013, Journal of shoulder and elbow surgery.

[25]  D. Kovacevic,et al.  Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate? , 2013, BMC Musculoskeletal Disorders.

[26]  Javed Ahmad,et al.  Open reduction and locking plate fixation of displaced proximal humerus fractures , 2013, Indian journal of orthopaedics.

[27]  A. Gavaskar,et al.  Complex Proximal Humerus Fractures Treated With Locked Plating Utilizing an Extended Deltoid Split Approach With a Shoulder Strap Incision , 2013, Journal of orthopaedic trauma.

[28]  B. Bakota,et al.  Internal fixation with locking plate of 3- and 4-part proximal humeral fractures in elderly patients: complications and functional outcome. , 2013, Acta clinica Croatica.

[29]  R. Barco,et al.  Minimally invasive poly-axial screw plating for three-part fractures of the proximal humerus. , 2012, Injury.

[30]  M. Innocenti,et al.  Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus. , 2012, Injury.

[31]  Alberto Naoki Miyazaki,et al.  Avaliação das complicações do tratamento cirúrgico das fraturas da extremidade proximal do úmero com "placa bloqueada" , 2012 .

[32]  G. Osterhoff,et al.  Calcar comminution as prognostic factor of clinical outcome after locking plate fixation of proximal humeral fractures. , 2012, Injury.

[33]  S. Chung,et al.  Outcomes for four-part proximal humerus fractures treated with a locking compression plate and an autologous iliac bone impaction graft. , 2012, Injury.

[34]  Chunxi Yang,et al.  Internal fixation versus shoulder hemiarthroplasty for displaced 4-part proximal humeral fractures in elderly patients. , 2012, Orthopedics.

[35]  S. Checchia,et al.  EVALUATION OF THE COMPLICATIONS OF SURGICAL TREATMENT OF FRACTURES OF THE PROXIMAL EXTREMITY OF THE HUMERUS USING A LOCKING PLATE , 2012, Revista brasileira de ortopedia.

[36]  Lars Henrik Frich,et al.  Benefits and harms of locking plate osteosynthesis in intraarticular (OTA Type C) fractures of the proximal humerus: a systematic review. , 2012, Injury.

[37]  J. Zuckerman,et al.  Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures. , 2012, Journal of shoulder and elbow surgery.

[38]  M. Komasi,et al.  Clinical results of using the proximal humeral internal locking system plate for internal fixation of displaced proximal humeral fractures. , 2012, American journal of orthopedics.

[39]  K. Rufibach,et al.  The PHILOS plate for proximal humeral fractures—Risk factors for complications at one year , 2012, The journal of trauma and acute care surgery.

[40]  P. Boileau,et al.  Epidemiology of proximal humerus fractures managed in a trauma center. , 2012, Orthopaedics & traumatology, surgery & research : OTSR.

[41]  T. Schildhauer,et al.  Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system? , 2012, Injury.

[42]  K. Strømsøe,et al.  Surgical Treatment With an Angular Stable Plate for Complex Displaced Proximal Humeral Fractures in Elderly Patients: A Randomized Controlled Trial , 2012, Journal of orthopaedic trauma.

[43]  C. Theisen,et al.  Complex fractures of the proximal humerus in the elderly—outcome and complications after locking plate fixation , 2012, MUSCULOSKELETAL SURGERY.

[44]  J. Fernández-Valencia,et al.  Comparative study between locking plates versus proximal humeral nail for the treatment of 2-part proximal humeral fractures , 2012, European Journal of Orthopaedic Surgery & Traumatology.

[45]  L. Audigé,et al.  Comparison of two different locking plates for two-, three- and four-part proximal humeral fractures—results of an international multicentre study , 2012, International Orthopaedics.

[46]  R. Neviaser,et al.  Proximal periarticular locking plates in proximal humeral fractures: functional outcomes. , 2011, Journal of shoulder and elbow surgery.

[47]  Tao Ge,et al.  Use of a proximal humeral internal locking system enhanced by injectable graft for minimally invasive treatment of osteoporotic proximal humeral fractures in elderly patients , 2011, Orthopaedic surgery.

[48]  Y. Tu,et al.  Locked plating for proximal humeral fractures: differences between the deltopectoral and deltoid-splitting approaches. , 2011, The Journal of trauma.

[49]  Jason R. Wild,et al.  Functional outcomes for surgically treated 3- and 4-part proximal humerus fractures. , 2011, Orthopedics.

[50]  A. van Kampen,et al.  Locking plate versus nonsurgical treatment for proximal humeral fractures: better midterm outcome with nonsurgical treatment. , 2011, Journal of shoulder and elbow surgery.

[51]  A. Schulz,et al.  Are Polyaxially Locked Screws Advantageous in the Plate Osteosynthesis of Proximal Humeral Fractures in the Elderly? A Prospective Randomized Clinical Observational Study , 2011, Journal of orthopaedic trauma.

[52]  S. Ponzer,et al.  Internal fixation versus nonoperative treatment of displaced 3-part proximal humeral fractures in elderly patients: a randomized controlled trial. , 2011, Journal of shoulder and elbow surgery.

[53]  Yong-Cheol Yoon,et al.  The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus. , 2011, The Journal of bone and joint surgery. British volume.

[54]  M. Frankle,et al.  Results of proximal humeral locked plating with supplemental suture fixation of rotator cuff. , 2011, Journal of shoulder and elbow surgery.

[55]  P. Regazzoni,et al.  Clinical Longer-Term Results After Internal Fixation of Proximal Humerus Fractures With a Locking Compression Plate (PHILOS) , 2011, Journal of orthopaedic trauma.

[56]  M. Torchia,et al.  Proximal Humerus Fractures in the Elderly Can Be Reliably Fixed With a “Hybrid” Locked-plating Technique , 2011, Clinical orthopaedics and related research.

[57]  B. Feeley,et al.  A systematic review of locking plate fixation of proximal humerus fractures. , 2011, Injury.

[58]  Guang-mao Lin,et al.  The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study , 2011, International Orthopaedics.

[59]  Jin Zhang,et al.  Locking intramedullary nails and locking plates in the treatment of two-part proximal humeral surgical neck fractures: a prospective randomized trial with a minimum of three years of follow-up. , 2011, The Journal of bone and joint surgery. American volume.

[60]  Daoyuan Wang,et al.  A Prospective Clinical Study of Proximal Humerus Fractures Treated With a Locking Proximal Humerus Plate , 2011, Journal of orthopaedic trauma.

[61]  A. Hawkins,et al.  Fixation of 3- and 4-part proximal humerus fractures using the PHILOS plate: mid-term results. , 2010, Orthopedics.

[62]  J. Tidermark,et al.  Quality of life and functional outcome after a 2-part proximal humeral fracture: a prospective cohort study on 50 patients treated with a locking plate. , 2010, Journal of shoulder and elbow surgery.

[63]  S. Aggarwal,et al.  Displaced proximal humeral fractures: an Indian experience with locking plates , 2010, Journal of orthopaedic surgery and research.

[64]  Florian Gebhard,et al.  Clinical Results for Minimally Invasive Locked Plating of Proximal Humerus Fractures , 2010, Journal of orthopaedic trauma.

[65]  L. Leddy,et al.  The results of ORIF of displaced unstable proximal humeral fractures using a locking plate. , 2010, Journal of shoulder and elbow surgery.

[66]  P. Clavert,et al.  Pitfalls and complications with locking plate for proximal humerus fracture. , 2010, Journal of shoulder and elbow surgery.

[67]  B. Olabi,et al.  Proximal humeral fractures with a severe varus deformity treated by fixation with a locking plate. , 2010, The Journal of bone and joint surgery. British volume.

[68]  J. Abboud,et al.  Use of locking plates in the treatment of proximal humerus fractures. , 2010, Journal of shoulder and elbow surgery.

[69]  Y. Kabukcuoglu,et al.  Locking plate fixation of three- and four-part proximal humeral fractures. , 2010, Acta orthopaedica et traumatologica turcica.

[70]  David Limb,et al.  Treatment of proximal humerus fractures with locking plates: a systematic review. , 2009, Journal of shoulder and elbow surgery.

[71]  J. Abboud,et al.  The use of precontoured humeral locking plates in the management of displaced proximal humerus fracture. , 2009, The Journal of the American Academy of Orthopaedic Surgeons.

[72]  B. Ockert,et al.  Outcome analysis following removal of locking plate fixation of the proximal humerus , 2008, BMC musculoskeletal disorders.

[73]  M. Mighell,et al.  Fixed-angle locked plating of two-, three-, and four-part proximal humerus fractures. , 2008, The Journal of the American Academy of Orthopaedic Surgeons.

[74]  R. Babst,et al.  Plating in Proximal Humeral Fractures , 2007, European Journal of Trauma and Emergency Surgery.

[75]  Kurt P Spindler,et al.  How to Write a Systematic Review , 2007, Clinical orthopaedics and related research.

[76]  C. Court-Brown,et al.  Epidemiology of adult fractures: A review. , 2006, Injury.

[77]  P. Giannoudis,et al.  The role and efficacy of retrograding nailing for the treatment of diaphyseal and distal femoral fractures: a systematic review of the literature. , 2005, Injury.

[78]  Erik N. Kubiak,et al.  Biomechanics of Locked Plates and Screws , 2004, Journal of orthopaedic trauma.

[79]  M. Leunig,et al.  Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. , 2004, Journal of shoulder and elbow surgery.

[80]  J. Gibson,et al.  Interventions for treating proximal humeral fractures in adults. , 2001, The Cochrane database of systematic reviews.