Three-field isocentric breast irradiation using asymmetric jaws and a tilt board.

Perfect abutment of medial and lateral tangential breast portals with the adjacent supraclavicular field may be achieved with ease. A simple and safe approach was developed using a tilt board and new technology that is standard on a popular linear accelerator. The patient is secured on a tilt board as a means to level the chest wall. Isocenter is placed at depth on the matchline, where asymmetric jaws are used to produce non-divergent field edges and a perfect abutment. This is done without the need for table or collimator rotations, beam-splitters, or vertical cephalad blocks. The dorsal beam edge of the tangents is made coplanar by rotating the gantry more than 180 degrees. This procedure produces a dosimetrically sharp field edge and eliminates concern about block transmission and excess dose to the contralateral breast. Set-up is fast, and the steps involved are simple and few. Advantages and limitations of this technique are presented.

[1]  G K Svensson,et al.  Three-field technique for breast treatment using a rotatable half-beam block. , 1981, International journal of radiation oncology, biology, physics.

[2]  F. Khan,et al.  Dosimetry of asymmetric x-ray collimators. , 1986, Medical physics.

[3]  E B Podgorsak,et al.  A simple isocentric technique for irradiation of the breast, chest wall and peripheral lymphatics. , 1984, The British journal of radiology.

[4]  J van de Geijn,et al.  A technique for field matching in primary breast irradiation. , 1983, International journal of radiation oncology, biology, physics.

[5]  G K Svensson,et al.  Three-field technique for breast irradiation using tangential field corner blocks. , 1983, International journal of radiation oncology, biology, physics.

[6]  R. Siddon,et al.  Can simulation measurements be used to predict the irradiated lung volume in the tangential fields in patients treated for breast cancer? , 1990, International journal of radiation oncology, biology, physics.

[7]  G E Hanks,et al.  A nondivergent three field matching technique for breast irradiation. , 1990, International journal of radiation oncology, biology, physics.

[8]  D. McShan,et al.  The influence of lung density corrections on treatment planning for primary breast cancer. , 1988, International journal of radiation oncology, biology, physics.

[9]  K. Kiel,et al.  Technique for breast irradiation using custom blocks conforming to the chest wall contour. , 1990, International Journal of Radiation Oncology, Biology, Physics.

[10]  H. Kogelnik,et al.  Inadequacy of conventional computerized tomography scans for treatment planning of tangential breast (chest wall) fields. , 1988, International journal of radiation oncology, biology, physics.

[11]  O. Nascimben,et al.  Three-field isocentric technique for breast irradiation using individualized shielding blocks. , 1988, International journal of radiation oncology, biology, physics.

[12]  M Norris The tangential breast match plane: practical problems and solutions. , 1989, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[13]  U F Rosenow,et al.  A technique for treating local breast cancer using a single set-up point and asymmetric collimation. , 1990, International journal of radiation oncology, biology, physics.