Evaluation of energy recovery of multiple skin facades: The approach of DIGITHON

Abstract Using of Double Skin Facade (DSF) became a very demanding trend in most kind of buildings, since it provides natural light, creates a connection between indoor inhabitants and the external environment without getting affected by harsh weather conditions. The verification of the balance equations to be used in a dynamic simulation software and the assessment of the active double-skin facade thermal performance in terms of energy recovery savings are the two main items of this study. For this purpose the software DIGITHON has been used. By comparing measured data of exit air temperature from a certain facade with calculated results, validation has been attained to use it in terms of buildings integrated with DSF. Highlighting benefits of using facade as a thermal energy recovery item during heating seasons on HVAC system is presented with respect to four European climatic zones for each orientation. Average pre-heat efficiency has been studied and illustrated on a seasonal scale.

[1]  Nader Sadegh,et al.  Real-time optimization of a double-skin facade based on lumped modeling and occupant preference , 2004 .

[2]  Jlm Jan Hensen,et al.  Modeling and simulation of a double-skin façade system , 2002 .

[3]  Carla Balocco,et al.  Thermal behaviour of interactive mechanically ventilated double glazed façade: Non-dimensional analysis , 2006 .

[4]  Michele De Carli,et al.  DIGITHON: A numerical model for the thermal balance of rooms equipped with radiant systems , 2012 .

[5]  Richard M. Aynsley,et al.  A resistance approach to analysis of natural ventilation airflow networks , 1997 .

[6]  Francesco Leccese,et al.  Ventilated facades energy performance in summer cooling of buildings , 2003 .

[7]  Jon Hand,et al.  CONTRASTING THE CAPABILITIES OF BUILDING ENERGY PERFORMANCE SIMULATION PROGRAMS , 2008 .

[8]  Thomas Blomberg HEAT3 A PC-program for heat transfer in three dimensions. Manual with brief theory and examples. , 1999 .

[9]  Dirk Saelens,et al.  Energy Performance Assessment of Multiple-Skin Facades , 2003 .

[10]  Nader Sadegh,et al.  Calibration of a lumped simulation model for double-skin façade systems , 2004 .

[11]  K. H. Haddad,et al.  Comparison of the monthly thermal performance of a conventional window and a supply-air window , 1998 .

[12]  Luisa F. Cabeza,et al.  Numerical modelling of ventilated facades: A review , 2013 .

[13]  Jörn von Grabe,et al.  A prediction tool for the temperature field of double facades , 2002 .

[14]  Fariborz Haghighat,et al.  Energy performance assessment of double-skin façade with thermal mass , 2010 .

[15]  H. Manz,et al.  Energy performance of glazings in European climates , 2012 .

[16]  Ahc van Paassen,et al.  Development of simplified tools for evaluation energy performance of double facades , 2000 .

[17]  Wonjun Choi,et al.  Load characteristics and operation strategies of building integrated with multi-story double skin facade , 2013 .

[18]  André De Herde,et al.  Greenhouse effect in double-skin facade , 2007 .

[19]  Kamaruzzaman Sopian,et al.  Perspectives of double skin façade systems in buildings and energy saving , 2011 .

[20]  Michele De Carli,et al.  Effect of modelling solar radiation on the cooling performance of radiant floors , 2011 .

[21]  S. Corgnati,et al.  Experimental assessment of the performance of an active transparent façade during actual operating conditions , 2007 .

[22]  D. G. Stephenson,et al.  Cooling load calculations by thermal response factor method , 1967 .

[23]  Carla Balocco,et al.  A non-dimensional analysis of a ventilated double façade energy performance , 2004 .