Determination of optimum insulation thickness based on cooling transmission load for building walls in a hot climate

Abstract The main objective of this study is to determine optimum insulation thickness according to cooling requirements of buildings in a hot climate. The investigation is carried out using an implicit finite difference method under steady periodic conditions for different wall orientations during the summer period in Antalya, Turkey. For this purpose, a computer program developed in Matlab is utilized. Firstly, thermal characteristics such as cooling transmission load, time lag, and decrement factor are calculated. Then, the optimum insulation thicknesses for all wall orientations are determined by using a cost analysis over lifetime of 20 years of the building. It is seen that for cooling season, the lowest value of optimum insulation thickness is obtained for the north-facing wall which has minimum cooling load while the highest thickness is obtained for the east and west walls providing the maximum cooling load. The results show that for cooling season, the most economical orientation is north with an optimum insulation thickness of 3.1 cm. Results obtained are also compared with the degree-days and degree-hours methods.

[1]  M. F. Zedan,et al.  Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model , 2005 .

[2]  S. A. Al-Sanea,et al.  Optimized monthly-fixed thermostat-setting scheme for maximum energy-savings and thermal comfort in air-conditioned spaces , 2008 .

[3]  Karolos-Nikolaos Kontoleon,et al.  The influence of wall orientation and exterior surface solar absorptivity on time lag and decrement factor in the Greek region , 2008 .

[4]  Haji Hassan Masjuki,et al.  CORRELATION BETWEEN THERMAL CONDUCTIVITY AND THE THICKNESS OF SELECTED INSULATION MATERIALS FOR BUILDING WALL , 2007 .

[5]  Meral Ozel,et al.  Cost analysis for optimum thicknesses and environmental impacts of different insulation materials , 2012 .

[6]  Francis W.H. Yik,et al.  Influence of thermal insulation position in building envelope on the space cooling of high-rise residential buildings in Hong Kong , 2001 .

[7]  Lina Yang,et al.  Cooling load reduction by using thermal mass and night ventilation , 2008 .

[8]  Orhan Büyükalaca,et al.  A case study for influence of building thermal insulation on cooling load and air-conditioning system in the hot and humid regions , 2010 .

[9]  H. T. Ozkahraman,et al.  The use of tuff stone cladding in buildings for energy conservation , 2006 .

[10]  Afif Hasan,et al.  Optimizing insulation thickness for buildings using life cycle cost , 1999 .

[11]  W. Beckman,et al.  Solar Engineering of Thermal Processes , 1985 .

[12]  Kamel Ghali,et al.  Optimal location and thickness of insulation layers for minimizing building energy consumption , 2012 .

[13]  Recep Yumrutaş,et al.  Comparison of experimental and theoretical results for the transient heat flow through multilayer walls and flat roofs , 2008 .

[14]  Meral Ozel,et al.  The influence of exterior surface solar absorptivity on thermal characteristics and optimum insulation thickness , 2012 .

[15]  Naouel Daouas,et al.  A study on optimum insulation thickness in walls and energy savings in Tunisian buildings based on analytical calculation of cooling and heating transmission loads , 2011 .

[16]  Hüsamettin Bulut,et al.  Analysis of variable-base heating and cooling degree-days for Turkey , 2001 .

[17]  S. A. Al-Sanea,et al.  Heat Transfer Characteristics and Optimum Insulation Thickness for Cavity Walls , 2003 .

[18]  O. Kaynakli,et al.  A study on residential heating energy requirement and optimum insulation thickness , 2008 .

[19]  Ali Bolatturk,et al.  Determination of optimum insulation thickness for building walls with respect to various fuels and climate zones in Turkey , 2006 .

[20]  S. A. Al-Sanea,et al.  Improving thermal performance of building walls by optimizing insulation layer distribution and thickness for same thermal mass , 2011 .

[21]  S. A. Al-Sanea,et al.  Optimum insulation thickness for building walls in a hot-dry climate , 2002 .

[22]  Kemal Çomaklı,et al.  Optimum insulation thickness of external walls for energy saving , 2003 .

[23]  Omer Kaynakli,et al.  A review of the economical and optimum thermal insulation thickness for building applications , 2012 .

[24]  Naouel Daouas,et al.  Analytical periodic solution for the study of thermal performance and optimum insulation thickness of building walls in Tunisia , 2010 .

[25]  Ö. Altan Dombaycı,et al.  Optimization of insulation thickness for external walls using different energy-sources , 2004 .

[26]  Meral Özel,et al.  Optimum location and distribution of insulation layers on building walls with various orientations , 2007 .

[27]  Milorad Bojić,et al.  Thermal insulation of cooled spaces in high rise residential buildings in Hong Kong , 2002 .

[28]  J. W. Ramsey,et al.  Thermal Environmental Engineering , 1970 .

[29]  Teuku Meurah Indra Mahlia,et al.  Cost benefits analysis and emission reductions of optimum thickness and air gaps for selected insulation materials for building walls in Maldives , 2010 .

[30]  S. A. Al-Sanea,et al.  Effect of thermal mass on performance of insulated building walls and the concept of energy savings potential , 2012 .

[31]  Emin Kahya,et al.  Determination of optimum insulation thicknesses of the external walls and roof (ceiling) for Turkey's different degree-day regions , 2007 .

[32]  Liwei Tian,et al.  A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of China , 2009 .

[33]  Ali Bolatturk,et al.  Optimum insulation thicknesses for building walls with respect to cooling and heating degree-hours in the warmest zone of Turkey , 2008 .

[34]  Meral Ozel,et al.  Thermal performance and optimum insulation thickness of building walls with different structure materials , 2011 .

[35]  Hongxing Yang,et al.  Investigation on the thermal performance of different lightweight roofing structures and its effect on space cooling load , 2009 .

[36]  Mohammed Al-Khawaja,et al.  Determination and selecting the optimum thickness of insulation for buildings in hot countries by accounting for solar radiation , 2004 .

[37]  Meral Ozel,et al.  Effect of wall orientation on the optimum insulation thickness by using a dynamic method , 2011 .