In-plane shear behaviour of unreinforced masonry panels strengthened with fibre reinforced polymer strips

Inserting fibre reinforced polymer (FRP) strips into pre-cut grooves in the surface of masonry walls is an emerging technique for the retrofit of unreinforced masonry (URM) structures. This method, known as near surface mounting (NSM), provides significant advantages over externally bonded FRP strips in that it has less of an effect on the aesthetics of a structure and can sustain higher loading before debonding. As this technique is relatively new, few studies into the behaviour of masonry walls strengthened using this technique have been conducted. A combined experimental and numerical program was conducted as part of this research project to study the in-plane shear behaviour of masonry wall panels strengthened with NSM carbon FRP (CFRP) strips. In this project the FRP strips were designed to resist sliding along mortar bed joints and diagonal cracking (through mortar joints and brick units). Both of these failure modes are common to masonry shear walls. Different reinforcement orientations were used, including: vertical; horizontal; and a combination of both. The first stage of the project involved characterising the bond between the FRP and the masonry using experimental pull tests (18 in total). From these tests the bond strength, the critical bond length and the local bond-slip relationship of the debonding interface was determined. The second stage of the project involved conducting diagonal tension/shear tests on masonry panels. A total of four URM wall panels and seven strengthened wall panels were tested. These tests were used to determine: the effectiveness of the reinforcement; the failure modes; the reinforcement mechanisms; and the behaviour of the bond between the masonry and the FRP in the case of a panel. The third stage of the project involved developing a finite element model to help understand the experimental results. The masonry was modelled using the micro-modelling approach, and the FRP was attached to the masonry model using the bond-slip relationships determined from the pull tests. Reinforcement schemes in which vertical FRP strips were used improved the strength and ductility of the masonry wall panels. When only horizontal strips were used to reinforce a wall panel, failure occurred along an un-strengthened bed joint and the increase in strength and ductility was negligible. The vertical reinforcement prevented URM sliding failure by restraining the opening (dilation) of the sliding cracks that developed through the mortar bed joints. The finite element model reproduced the key behaviours observed in the experiments for both the unreinforced and FRP strengthened wall panels. This model would potentially be useful for the development of design equations.

[1]  J. Comyn,et al.  Structural Adhesive Joints in Engineering , 1984, The Aeronautical Journal (1968).

[2]  Pedro F. Silva,et al.  Strengthening of Masonry Walls by FRP Structural Repointing , 2001 .

[3]  Robert Park,et al.  Evaluation of ductility of structures and structural assemblages from laboratory testing , 1989 .

[4]  Antonio Nanni,et al.  Analysis of unreinforced masonry concrete walls strengthened with glass fiber-reinforced polymer bars , 2005 .

[5]  T. Stratford,et al.  Shear Strengthening Masonry Panels with Sheet Glass-Fiber Reinforced Polymer , 2004 .

[6]  Thanasis Triantafillou,et al.  Composites: a new possibility for the shear strengthening of concrete, masonry and wood , 1998 .

[7]  Mark J. Masia Torsion testing for the characterisation of the shear behaviour of mortar joints in masonry , 2006 .

[8]  A. Al-Saidy,et al.  SHEAR BEHAVIOR OF URM RETROFITTED WITH FRP OVERLAYS , 1997 .

[9]  Jian fei Chen,et al.  Anchorage strength models for FRP and steel plates bonded to concrete , 2001 .

[10]  Gabriele Milani,et al.  Modelling and analysis of FRP-strengthened masonry panels , 2008 .

[11]  Medhat A. Haroun,et al.  Seismic performance testing of masonry-infilled frames retrofitted by fiber composite , 1997 .

[12]  Yan Han A study of two-way bending in unreinforced masonry , 2007 .

[13]  Pablo Alcaino,et al.  EXPERIMENTAL RESPONSE OF MASONRY WALLS EXTERNALLY REINFORCED WITH CARBON FIBER FABRICS , 2006 .

[14]  Jan G. Rots,et al.  Structural Masonry , 2020 .

[15]  P. Lestuzzi,et al.  Aseismic retrofitting of unreinforced masonry walls using FRP , 2005 .

[16]  Jian Xie,et al.  Shear Behavior of UCMW using CFRP Sheet: A Case Study , 2004 .

[17]  Costas P. Antonopoulos,et al.  Design of Concrete Flexural Members Strengthened in Shear with FRP , 2000 .

[18]  Deric J. Oehlers,et al.  Design of FRP and Steel Plated RC Structures: Retrofitting Beams and Slabs for Strength, Stiffness and Ductility , 2004 .

[19]  Tim Stratford,et al.  Shear analysis of concrete with brittle reinforcement , 2001 .

[20]  Hai-Sui Yu,et al.  Lower bound limit analysis of unreinforced masonry shear walls , 2001, Numerical Models in Geomechanics.

[21]  Wael W. El-Dakhakhni,et al.  In-Plane Strengthening of URM Infill Wall Assemblages Using GFRP Laminates , 2004 .

[22]  M. Corradi,et al.  Strengthening techniques tested on masonry structures struck by the Umbria-Marche earthquake of 1997-1998 , 2002 .

[23]  Fernando Fraternali,et al.  Load carrying capacity of 2D FRP/strengthened masonry structures , 2005 .

[24]  Federico M. Mazzolani,et al.  Lateral-Loading Tests on a Real RC Building Including Masonry Infill Panels with and without FRP Strengthening , 2008 .

[25]  C. Modena,et al.  Shear behavior of masonry panels strengthened by FRP laminates , 2002 .

[26]  P. Lourenço Computational strategies for masonry structures : Proefschrift , 1996 .

[27]  G. Zijl,et al.  Modeling Masonry Shear-Compression: Role of Dilatancy Highlighted , 2004 .

[28]  M. Elgaaly,et al.  Behavior of Composite Unreinforced Masonry–Fiber-Reinforced Polymer Wall Assemblages Under In-Plane Loading , 2005 .

[29]  B. Binici,et al.  Strength of carbon fiber reinforced polymers bonded to concrete and masonry , 2007 .

[30]  G. Zijl,et al.  Masonry Wall Crack Control with Carbon Fiber Reinforced Polymer , 2005 .

[31]  G. Klopp,et al.  Seismic Analysis of Unreinforced Masonry Buildings , 1998 .

[32]  Deric J. Oehlers,et al.  Generic Debonding Resistance of EB and NSM Plate-to-Concrete Joints , 2007 .

[33]  Adrian Page Unreinforced masonry structures : An Australian overview , 1996 .

[34]  R. van der Pluijm,et al.  Non-linear behaviour of masonry under tension , 1997 .

[35]  P. Lourenço,et al.  Multisurface Interface Model for Analysis of Masonry Structures , 1997 .

[36]  L.G.W. Verhoef,et al.  Re-strengthening of brickwork to reduce crack width , 2002 .

[37]  Robert G. Drysdale,et al.  Masonry Structures: Behavior and Design , 1993 .

[38]  Pierino Lestuzzi,et al.  A REVIEW OF CONVENTIONAL SEISMIC RETROFITTING TECHNIQUES FOR URM , 2004 .

[39]  D. Oehlers,et al.  IC Debonding of FRP NSM and EB Retrofitted Concrete: Plate and Cover Interaction Tests , 2008 .

[40]  Mark J. Masia,et al.  Torsion shear test for mortar joints in masonry: preliminary experimental results , 2007 .

[41]  Maria Rosa Valluzzi,et al.  Flexural and shear strengthening of un-reinforced masonry with FRP bars , 2006 .

[42]  G. K. Al-Chaar,et al.  Dynamic response and seismic testing of CMU walls rehabilitated with composite material applied to only one side , 2002 .

[43]  Y Zhuge,et al.  Seismic Retrofitting of Unreinforced Masonry Buildings – A Literature Review , 2005 .

[44]  H. Hamilton,et al.  Strengthening URM with GFRP Composites and Ductile Connections , 2002 .

[45]  Gian Michele Calvi,et al.  In‐plane seismic response of brick masonry walls , 1997 .

[46]  Pierino Lestuzzi,et al.  In-Plane Seismic Response of URM Walls Upgraded with FRP , 2005 .

[47]  Paulo B. Lourenço Structural masonry analysis : recent developments and prospects , 2008 .

[48]  S. Hussain,et al.  PREDICTION OF ELACTIC PROPERTIES OF FRP COMPOSITE LAMINA FOR LONGITUDINAL LOADING , 2008 .

[49]  Jian fei Chen,et al.  Experimental study on FRP-to-concrete bonded joints , 2005 .

[50]  P. Lestuzzi,et al.  STATIC CYCLIC RESPONSE OF MASONRY WALLS RETROFITTED WITH FIBER-REINFORCED POLYMERS , 2007 .

[51]  Deric J. Oehlers,et al.  Bond Strength of Near-Surface Mounted FRP Strip-to-Concrete Joints , 2007 .

[52]  D. A. Howells,et al.  Earthquake design practice for buildings by David E. Key, Thomas Telford publications, London, 1988. no. of pages: 218: U. K. £35; overseas £40 by air , 1989 .

[53]  Zhishen Wu Structural strengthening and integrity with hybrid FRP composites , 2004 .

[54]  Juan I V DIMAS,et al.  SEISMIC RETROFIT OF URM WALLS WITH FIBER COMPOSITES , 1999 .

[55]  Miha Tomazevic,et al.  Earthquake-Resistant Design of Masonry Buildings , 1999 .

[56]  N. Shrive The use of fibre reinforced polymers to improve seismic resistance of masonry , 2006 .

[57]  Tamon Ueda,et al.  New shear bond model for FRP–concrete interface – from modeling to application , 2004 .

[58]  A. Prota,et al.  In-plane shear performance of masonry panels strengthened with FRP , 2007 .

[60]  Minoru Wakabayashi Design of earthquake-resistant buildings , 1985 .

[61]  E. Jacquelin,et al.  Analysis of the in-plane shear behaviour of FRP reinforced hollow brick masonry walls , 2005 .

[62]  Michel Bruneau,et al.  State-of-the-art report on seismic performance of unreinforced masonry buildings , 1995 .

[63]  Paulo B. Lourenço,et al.  Testing and modelling of multiple-leaf masonry walls under shear and compression, , 2004 .

[64]  E. Jacquelin,et al.  Modelling approaches of the in-plane shear behaviour of unreinforced and FRP strengthened masonry panels , 2006 .