Comparing electro- and mechano-myographic muscle activation patterns in self-paced pediatric gait.

Electromyography (EMG) is the standard modality for measuring muscle activity. However, the convenience and availability of low-cost accelerometer-based wearables makes mechanomyography (MMG) an increasingly attractive alternative modality for clinical applications. Literature to date has demonstrated a strong association between EMG and MMG temporal alignment in isometric and isokinetic contractions. However, the EMG-MMG relationship has not been studied in gait. In this study, the concurrence of EMG- and MMG-detected contractions in the tibialis anterior, lateral gastrocnemius, vastus lateralis, and biceps femoris muscles were investigated in children during self-paced gait. Furthermore, the distribution of signal power over the gait cycle was statistically compared between EMG-MMG modalities. With EMG as the reference, muscular contractions were detected based on MMG with balanced accuracies between 88 and 94% for all muscles except the gastrocnemius. MMG signal power differed from that of EMG during certain phases of the gait cycle in all muscles except the biceps femoris. These timing and power distribution differences between the two modalities may in part be related to muscle fascicle length changes that are unique to muscle motion during gait. Our findings suggest that the relationship between EMG and MMG appears to be more complex during gait than in isometric and isokinetic contractions.

[1]  Denise Taylor,et al.  A review of e-textiles in neurological rehabilitation: How close are we? , 2016, Journal of NeuroEngineering and Rehabilitation.

[2]  R. Stein,et al.  Turning strategies during human walking. , 1999, Journal of neurophysiology.

[3]  Roberto Merletti,et al.  Surface Electromyography: Physiology, engineering, and applications , 2016 .

[4]  D. Sutherland,et al.  The Development of Mature Gait , 1997 .

[5]  Marc F Norcross,et al.  Comparison of hamstring neuromechanical properties between healthy males and females and the influence of musculotendinous stiffness. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[6]  C. Orizio,et al.  Surface mechanomyogram reflects muscle fibres twitches summation. , 1996, Journal of biomechanics.

[7]  T. Fukunaga,et al.  In vivo behaviour of human muscle tendon during walking , 2001, Proceedings of the Royal Society of London. Series B: Biological Sciences.

[8]  T J Housh,et al.  Mean power frequency and amplitude of the mechanomyographic and electromyographic signals during incremental cycle ergometry. , 2001, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[9]  E. Jarocka,et al.  Electromyography and mechanomyography of elbow agonists and antagonists in Parkinson disease , 2009, Muscle & nerve.

[10]  Tom Chau,et al.  The Effects of Rhythmic Sensory Cues on the Temporal Dynamics of Human Gait , 2012, PloS one.

[11]  Vinzenz von Tscharner,et al.  Time/frequency events of surface mechanomyographic signals resolved by nonlinearly scaled wavelets , 2008, Biomed. Signal Process. Control..

[12]  Kemal S. Türker,et al.  Effect of gender, age, fatigue and contraction level on electromechanical delay , 2010, Clinical Neurophysiology.

[13]  F. Esposito,et al.  Stretch-induced changes in tension generation process and stiffness are not accompanied by alterations in muscle architecture of the middle and distal portions of the two gastrocnemii. , 2015, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[14]  J. Perry,et al.  Gait Analysis , 2024 .

[15]  F. Lacquaniti,et al.  Five basic muscle activation patterns account for muscle activity during human locomotion , 2004, The Journal of physiology.

[16]  Terry J Housh,et al.  MMG and EMG responses during 25 maximal, eccentric, isokinetic muscle actions. , 2003, Medicine and science in sports and exercise.

[17]  Toshio Moritani,et al.  Characteristics of surface mechanomyogram are dependent on development of fusion of motor units in humans. , 2002, Journal of applied physiology.

[18]  Darin A Padua,et al.  Repeatability of surface EMG during gait in children. , 2005, Gait & posture.

[19]  P Madeleine,et al.  Mechanomyography and electromyography force relationships during concentric, isometric and eccentric contractions. , 2001, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[20]  Takao Someya,et al.  Printable elastic conductors with a high conductivity for electronic textile applications , 2015, Nature Communications.

[21]  J. Marusiak,et al.  Similar response of agonist and antagonist muscles after eccentric exercise revealed by electromyography and mechanomyography. , 2007, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[22]  Susanna Rampichini,et al.  Novel insights into skeletal muscle function by mechanomyography: from the laboratory to the field , 2015, Sport Sciences for Health.

[23]  Y. Zheng,et al.  Detection of the electromechanical delay and its components during voluntary isometric contraction of the quadriceps femoris muscle , 2014, Front. Physiol..

[24]  Gary S Chleboun,et al.  Fascicle length change of the human tibialis anterior and vastus lateralis during walking. , 2007, The Journal of orthopaedic and sports physical therapy.

[25]  Anna Jaskólska,et al.  The effect of skinfold on frequency of human muscle mechanomyogram. , 2004, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[26]  Motoki Kouzaki,et al.  Mechanomyography of the human quadriceps muscle during incremental cycle ergometry , 1997, European Journal of Applied Physiology and Occupational Physiology.

[27]  Y. Koryak Functional and clinical significance of the architecture of human skeletal muscles , 2008, Human Physiology.

[28]  T. Fukunaga,et al.  Muscle and Tendon Interaction During Human Movements , 2002, Exercise and sport sciences reviews.

[29]  C. Orizio,et al.  The surface mechanomyogram as a tool to describe the influence of fatigue on biceps brachii motor unit activation strategy. Historical basis and novel evidence , 2003, European Journal of Applied Physiology.

[30]  Anna Jaskólska,et al.  EMG and MMG activities of agonist and antagonist muscles in Parkinson's disease patients during absolute submaximal load holding. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[31]  Pascal Madeleine,et al.  A comparison between mechanomyographic condenser microphone and accelerometer measurements during submaximal isometric, concentric and eccentric contractions. , 2007, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[32]  Percy Nohama,et al.  Advances and perspectives of mechanomyography , 2014 .

[33]  T Moritani,et al.  The muscle sound properties of different muscle fiber types during voluntary and electrically induced contractions. , 1999, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[34]  H. Dawes,et al.  Wearable accelerometry-based technology capable of assessing functional activities in neurological populations in community settings: a systematic review , 2014, Journal of NeuroEngineering and Rehabilitation.

[35]  F. Lacquaniti,et al.  Motor patterns in human walking and running. , 2006, Journal of neurophysiology.

[36]  P. Komi,et al.  EMG power spectrum and features of the superimposed M-wave during voluntary eccentric and concentric actions at different activation levels , 2002, European Journal of Applied Physiology.