Resolution in soft X-ray microscopes

Abstract X-Ray microscopes are able to image thick, wet biological specimens at 50 mm or better resolution, to perform elemental analysis at 0.1–10 μm resolution with as high as ppm sensitivity, and to analyze surface composition at 0.1–1 μm resolution. We concentrate here on the use of soft X-rays, where the wavelength is typically >1 nm, although mention of some techniques and results at shorter wavelength is also made. We discuss the physical priciples behind X-ray microscopes, the types of optical systems used and their achievable resolution. resolution limitations imposed by radiation damage, and recent application of X-ray microscopes to the imaging of biological, materials science, geological, and other specimens.

[1]  K. Kohra,et al.  Characterization of sliced multilayer zone plates for hard x rays (invited) , 1989 .

[2]  S. Suckewer,et al.  The effect of prepulse on X-ray laser development using a powerful subpicosecond KrF laser , 1990 .

[3]  Janos Kirz,et al.  Phase zone plates for x rays and the extreme uv , 1974 .

[4]  T. Hirano,et al.  High resolution monochromatic tomography with x‐ray sensing pickup tube , 1989 .

[5]  Ralph Feder,et al.  Soft X‐ray contact microscopy with nanosecond exposure times , 1985 .

[6]  G. T. Trammell,et al.  Molecular Microscopy: Fundamental Limitations , 1970, Science.

[7]  F S Fay,et al.  Three‐dimensional molecular distribution in single cells analysed using the digital imaging microscope , 1989, Journal of microscopy.

[8]  M. A. Hayat,et al.  Principles and Techniques of Electron Microscopy , 1975 .

[9]  L. Reimer,et al.  Scanning Electron Microscopy , 1984 .

[10]  A. Michette X-ray microscopy , 1988 .

[11]  David A. Agard,et al.  Three-dimensional architecture of a polytene nucleus , 1983, Nature.

[12]  Ping-chin Cheng,et al.  X-Ray Microscopy: Instrumentation and Biological Applications , 1987 .

[13]  D. Sayre,et al.  Improved detail in biological soft X-ray microscopy: study of blood platelets. , 1981, Science.

[14]  A. V. Daryin,et al.  Scanning x‐ray fluorescent microanalysis of rock samples , 1989 .

[15]  P. J. Viccaro,et al.  Coherent hard x‐ray focusing optics and applications , 1992 .

[16]  U. Valdré,et al.  Surface and Interface Characterization by Electron Optical Methods , 1989 .

[17]  M. Rosen,et al.  Wavelength choice for soft x-ray laser holography of biological samples. , 1989, Applied optics.

[18]  Antonio Bianconi,et al.  Biophysics and Synchrotron Radiation , 1987 .

[19]  D. Sayre,et al.  RECENT DEVELOPMENTS IN X‐RAY CONTACT MICROSCOPY , 1980 .

[20]  T Kanayama,et al.  Three-dimensional readout of flash x-ray images of living sperm in water by atomic-force microscopy. , 1991, Science.

[21]  J. Kortright,et al.  The Photoemission Spectromicroscope Multiple-Application X-Ray-Imaging Undulator Microscope (Maximum) , 1990 .

[22]  E. Wolf Three-dimensional structure determination of semi-transparent objects from holographic data , 1969 .

[23]  Kunjo Shinohara X-Ray Microscopy in Biology and Medicine , 1990 .

[24]  R. Tatchyn,et al.  Optimization of planar metallic nonrefracting transmission-grating profiles for mth-order intensity maximization in the soft-x-ray range , 1982 .

[25]  Francesco Sette,et al.  Performance of the Dragon soft x‐ray beamline (invited) , 1989 .

[26]  Mark L. Rivers,et al.  Computerized microtomography using synchrotron radiation from the NSLS , 1986 .

[27]  Mark L. Schattenburg,et al.  Absence of resolution degradation in X-ray lithography for l from 4.5 nm to 0.83 nm , 1990 .

[28]  R Roots,et al.  Protection of DNA molecules of cultured mammalian cells from radiation-induced single-strand scissions by various alcohols and SH compounds. , 1972, International journal of radiation biology and related studies in physics, chemistry, and medicine.

[29]  Graeme Morrison,et al.  Development of x‐ray imaging at the Daresbury SRS , 1989 .

[30]  Rudolf Germer,et al.  X‐ray TV camera at 4.5 nm , 1986 .

[31]  S. Lowenthal,et al.  Quantitative mapping of atomic species by X-ray absorption spectroscopy and contact microradiography , 1983 .

[32]  J. Goodman Introduction to Fourier optics , 1969 .

[33]  Weaver,et al.  Demonstration of a soft x-ray amplifier. , 1985, Physical review letters.

[34]  Janos Kirz,et al.  MAPPING THE DISTRIBUTION OF PARTICULAR ATOMIC SPECIES * , 1980 .

[35]  E. Anderson,et al.  Astigmatism correction in x-ray scanning photoemission microscope with use of elliptical zone plate , 1992 .

[36]  Janos Kirz,et al.  Characterization of phosphors in the soft X-ray region , 1987 .

[37]  M. T. Browne,et al.  Diffraction-limited imaging in a scanning transmission x-ray microscope , 1991, Optical Society of America Annual Meeting.

[38]  P. C. Gabriele,et al.  Tabletop x-ray microscope using 8 keV zone plates , 1990 .

[39]  P. Horowitz,et al.  A Scanning X-Ray Microscope Using Synchrotron Radiation , 1972, Science.

[40]  H. A. Liebhafsky,et al.  X‐Ray Microscopy , 1961 .

[41]  J. Kirz,et al.  Soft x‐ray microscopes , 1985 .

[42]  Sadao Aoki,et al.  Development of a scanning x‐ray microprobe with synchrotron radiation , 1989 .

[43]  M. Ando,et al.  Soft x‐ray microscope at the undulator beamline of the Photon Factory , 1989 .

[44]  K. Shinohara,et al.  Radiation damage in soft X‐ray microscopy of live mammalian cells , 1991, Journal of microscopy.

[45]  D. K. Bowen,et al.  The synchrotron radiation microprobe at the SRS, daresbury (UK) and its applications , 1990 .

[46]  Albert Rose,et al.  A Unified Approach to the Performance of Photographic Film, Television Pickup Tubes, and the Human Eye * --> , 1946 .

[47]  J. Kirz,et al.  X-Ray Microscopy II , 1988 .

[48]  J. Cazaux,et al.  X-Ray Projection Microscopy and Microtomography in a Scanning Electron Microscope , 1992 .

[49]  V. E. Cosslett,et al.  X‐Ray Optics and X‐Ray Microanalysis , 1964 .

[50]  Chris Jacobsen,et al.  X-ray holographic microscopy using photoresists , 1990, Annual Meeting Optical Society of America.

[51]  R. Henderson,et al.  Images of purple membrane at 2.8 A resolution obtained by cryo-electron microscopy. , 1988, Journal of molecular biology.

[52]  Coherent Radiation for X-Ray Imaging-The Soft X-Ray Undulator and the X1A Beamline at the NSLS. , 1990 .

[53]  Mark L. Rivers,et al.  Elemental imaging of cartilage by scanning x‐ray microscopy , 1992 .

[54]  B. Flannery,et al.  Three-Dimensional X-ray Microtomography , 1987, Science.

[55]  R Roots,et al.  Estimation of life times and diffusion distances of radicals involved in x-ray-induced DNA strand breaks of killing of mammalian cells. , 1975, Radiation research.

[56]  J. Kirz,et al.  Quantitative imaging and microanalysis with a scanning soft x-ray microscope. , 1987, Physics in Medicine and Biology.

[57]  Alan Michette,et al.  Soft X-ray contact microscopy☆ , 1986 .

[58]  S. Aoki,et al.  X-ray microanalysis with energy tunable synchrotron X-rays , 1990 .

[59]  Graeme Morrison,et al.  Dark-field imaging with the scanning transmission x-ray microscope , 1992 .

[60]  R Feder,et al.  High-resolution soft x-ray microscopy. , 1977, Science.

[61]  Mark L. Schattenburg,et al.  Electromagnetic calculation of soft x‐ray diffraction from 0.1‐μm scale gold structures , 1991 .

[62]  Graeme Morrison,et al.  X-Ray Microscopy III , 1992 .

[63]  Alan G. Michette,et al.  Optical Systems for Soft X Rays , 2011, Springer US.

[64]  Williams,et al.  Far-infrared transmission study of single-crystal Bi2Sr2Ca1Cu2Ox superconductors. , 1990, Physical review letters.

[65]  B. Niemann,et al.  X-ray microscopy with synchrotron radiation. , 1976, Applied optics.

[66]  Johndale C. Solem,et al.  Imaging biological specimens with high-intensity soft x rays , 1986 .

[67]  D. Tennant,et al.  Construction and test of phase zone plates for x-ray microscopy. , 1991, Optics letters.

[68]  G. Harp,et al.  Photoelectron microscopy with synchrotron radiation , 1988 .

[69]  K. Shinohara,et al.  A NEW APPROACH TO THE OBSERVATION OF THE RESIST IN X‐RAY CONTACT MICROSCOPY , 1986, Photochemistry and photobiology.

[70]  Keane,et al.  Demonstration of x-ray amplifiers near the carbon K edge. , 1990, Physical review letters.

[71]  D. Goodhead,et al.  Chromosome aberrations induced in human lymphocytes by ultrasoft Al (K) and C (K) X-rays. , 1980, International journal of radiation biology and related studies in physics, chemistry, and medicine.

[72]  R Feder,et al.  Transmission microscropy of unmodified biological materials: comparative radiation dosages with electrons and ultrasoft x-ray photons. , 1977, Ultramicroscopy.

[73]  Keith W. Jones,et al.  Determination of polymerization particle morphology using synchrotron computed microtomography , 1992 .

[74]  R. Glaeser,et al.  Radiation damage relative to transmission electron microscopy of biological specimens at low temperature: a review , 1978, Journal of microscopy.

[75]  J. Kirz,et al.  High-Resolution Imaging by Fourier Transform X-ray Holography , 1992, Science.

[76]  H. Wolter Spiegelsysteme streifenden Einfalls als abbildende Optiken für Röntgenstrahlen , 1952 .

[77]  Rainer Lebert,et al.  An x-ray microscope with a plasma x-ray source , 1990 .

[78]  X-ray microanalysis near an absorption edge using synchrotron radiation: How to obtain quantitative results , 1982 .

[79]  H. Rarback,et al.  Absorption microanalysis with a scanning soft X‐ray microscope: mapping the distribution of calcium in bone , 1985, Journal of microscopy.

[80]  Shawn P. Williams,et al.  X‐ray stereomicroscopy: high resolution 3‐D imaging of human spermatozoa in aqueous suspension with natural contrast , 1992, Journal of microscopy.

[81]  Graeme Morrison,et al.  The use of avalanche photodiodes for the detection of soft x rays , 1992 .

[82]  G. Schmahl,et al.  Status Of The Sputtered Sliced Zone Plates For X-Ray Microscopy , 1982, Other Conferences.

[83]  Keane,et al.  Amplification of stimulated soft x-ray emission in a confined plasma column. , 1985, Physical review letters.

[84]  Sebastian Doniach,et al.  Synchrotron Radiation Research , 1978, Springer US.

[85]  Dennis L. Matthews,et al.  Demonstration of X-ray Holography with an X-ray Laser , 1987, Science.

[86]  Reginald W. James,et al.  The Optical principles of the diffraction of X-rays , 1948 .

[87]  B Reuter,et al.  Experiments with Fourier transform holograms using 4.48 nm X-rays , 1976 .

[88]  J. H. Hubbell,et al.  Pair, Triplet, and Total Atomic Cross Sections (and Mass Attenuation Coefficients) for 1 MeV-100 GeV Photons in Elements Z=1 to 100, , 1980 .

[89]  Denis Joyeux,et al.  Principle Of A "Reconstruction Microscope" For High Resolution X-Ray Holography , 1989, Other Conferences.

[90]  Fumihiko Uchida,et al.  X-Ray Focusing with Elliptical Kirkpatrick-Baez Mirror System , 1991 .

[91]  Asher Peres,et al.  Gravitational radiation damping of nongravitational motion , 1960 .

[92]  A. G. Michette,et al.  The effects of manufacturing inaccuracies on the imaging properties of Fresnel zone plates , 1983 .

[93]  Erik H. Anderson,et al.  X-ray spectromicroscopy with a zone plate generated microprobe , 1990 .

[94]  T. J. Tanaka,et al.  Low-energy x-ray interaction coefficients: Photoabsorption, scattering, and reflection: E = 100–2000 eV Z = 1–94☆ , 1982 .

[95]  Mark L. Rivers,et al.  A tunable X-ray microprobe using synchrotron radiation , 1989 .

[96]  D. K. Bowen,et al.  Ellipsoid X-ray focussing for synchrotron-radiation microprobe analysis at the SRS, Daresbury, UK , 1990 .

[97]  D T Goodhead,et al.  Effectiveness of 0.3 keV carbon ultrasoft X-rays for the inactivation and mutation of cultured mammalian cells. , 1979, International journal of radiation biology and related studies in physics, chemistry, and medicine.

[98]  P. Horowitz SOME EXPERIENCES WITH X‐RAY AND PROTON MICROSCOPES * , 1978 .

[99]  T. W. Ford,et al.  A comparison of soft X‐ray contact microscopy with light and electron microscopy for the study of algal cell ultrastructure , 1988 .

[100]  W A Ladd,et al.  High-Resolution Microradiography. , 1956, Science.

[101]  R. Browning,et al.  Core level photoelectron microscopy with synchrotron radiation (invited) , 1989 .

[102]  Soft-X-ray microscope using fourier transform holography , 1989 .