Assessing the Validity of Attitude and Heading Reference Systems for Biomechanical Evaluation of Motions - A Methodological Proposal

Background: Attitude and Heading Reference Systems’ (AHRS) popularity in biomechanics has been growing rapidly over the past few years. However, the limits of operation and performances of such systems for motion capture are highly dependent upon their conditions of use and the environment they operate in. The objectives of this paper are to: (1) propose a methodology for the characterization of the criterion of validity of accuracy of AHRS in a human biomechanical context; and (2) suggest a set of outcome measures to assess the accuracy of AHRS. Methods: The criterion validity of accuracy is established using an optical motion tracking gold standard under standardized human motions. Results: Global assessment of accuracy is derived by comparing the orientation data provided by the AHRS to those given by the gold standard using a coefficient of multiple correlation. Peak values and RMS difference between both sets of orientation data are also analysed to complete the accuracy portrait. The methodology proposed herein is verified for the knee during regular walk. Conclusion: The proposed methodology and analyses take into consideration the complexities and processes required to assess the accuracy of AHRS in their context of use and provide a standardized approach to report.

[1]  Martina Mancini,et al.  Objective biomarkers of balance and gait for Parkinson's disease using body‐worn sensors , 2013, Movement disorders : official journal of the Movement Disorder Society.

[2]  Bertil Magnusson,et al.  Understanding the meaning of accuracy, trueness and precision , 2007 .

[3]  M A Brodie,et al.  The static accuracy and calibration of inertial measurement units for 3D orientation , 2008, Computer methods in biomechanics and biomedical engineering.

[4]  A. Cappozzo,et al.  A spot check for assessing static orientation consistency of inertial and magnetic sensing units. , 2011, Gait & posture.

[5]  P H Veltink,et al.  Ambulatory measurement of arm orientation. , 2007, Journal of biomechanics.

[6]  Pietro Garofalo,et al.  First in vivo assessment of “Outwalk”: a novel protocol for clinical gait analysis based on inertial and magnetic sensors , 2009, Medical & Biological Engineering & Computing.

[7]  Daniele Giansanti,et al.  Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects , 2007, Medical & Biological Engineering & Computing.

[8]  Marco Piras,et al.  Performances comparison of different MEMS-based IMUs , 2010, IEEE/ION Position, Location and Navigation Symposium.

[9]  Xiaoping Yun,et al.  An investigation of the effects of magnetic variations on inertial/magnetic orientation sensors , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[10]  Markus Windolf,et al.  Systematic accuracy and precision analysis of video motion capturing systems--exemplified on the Vicon-460 system. , 2008, Journal of biomechanics.

[11]  L. Rocchi,et al.  A simple test to assess the static and dynamic accuracy of an inertial sensors system for human movement analysis , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  A. Cappello,et al.  A new formulation of the coefficient of multiple correlation to assess the similarity of waveforms measured synchronously by different motion analysis protocols. , 2010, Gait & posture.

[13]  Laura Rocchi,et al.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors , 2008, Medical & Biological Engineering & Computing.

[14]  F. V. D. van der Helm,et al.  Magnetic distortion in motion labs, implications for validating inertial magnetic sensors. , 2009, Gait & posture.

[15]  Patrick Boissy,et al.  Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions - Effect of Velocity , 2013, PloS one.