Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart
暂无分享,去创建一个
David M Higgins | Sebastian Kozerke | Aleksandra Radjenovic | John P Ridgway | Daniel R Messroghli | Mohan U Sivananthan | J. Ridgway | M. Sivananthan | A. Radjenovic | S. Kozerke | D. Messroghli | D. Higgins
[1] O. Simonetti,et al. Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function. , 1999, Circulation.
[2] B K Rutt,et al. A fast 3D look-locker method for volumetric T1 mapping. , 1999, Magnetic resonance imaging.
[3] D. Look,et al. Time Saving in Measurement of NMR and EPR Relaxation Times , 1970 .
[4] B. Nordell,et al. Phantom and in vivo study of the Look-Locher T1 mapping method. , 1999, Magnetic resonance imaging.
[5] J. Schulz-Menger,et al. T1 mapping in patients with acute myocardial infarction. , 2003, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.
[6] M. Bock,et al. Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: Assessment using T*2 and T1 measurements , 1999, Magnetic resonance in medicine.
[7] Bruce R. Rosen,et al. Measurement of spin-lattice relaxation times in nuclear magnetic resonance imaging. , 1983, Physics in Medicine and Biology.
[8] J Hennig,et al. T1 quantification with inversion recovery TrueFISP , 2001, Magnetic resonance in medicine.
[9] D. Ziessow,et al. Error analysis for optimized inversion recovery spin-lattice relaxation measurements , 1977 .
[10] C H Lorenz,et al. Characterization of t1 relaxation and blood‐myocardial contrast enhancement of NC100150 injection in cardiac MRI , 1999, Journal of magnetic resonance imaging : JMRI.
[11] P L Carson,et al. Determination of sample time for T1 measurement , 1998, Journal of magnetic resonance imaging : JMRI.
[12] Katherine C. Wu,et al. Prognostic significance of microvascular obstruction by magnetic resonance imaging in patients with acute myocardial infarction. , 1998, Circulation.
[13] L R Schad,et al. Fast and precise T1 imaging using a TOMROP sequence. , 1990, Magnetic resonance imaging.
[14] C. Lorenz,et al. Measurement of the gadopentetate dimeglumine partition coefficient in human myocardium in vivo: normal distribution and elevation in acute and chronic infarction. , 2001, Radiology.
[15] R Deichmann,et al. Quantification of T1 values by SNAPSHOT-FLASH NMR imaging , 1992 .
[16] Georg Ertl,et al. Quantitative assessment of myocardial perfusion with a spin‐labeling technique: Preliminary results in patients with coronary artery disease , 2003, Journal of magnetic resonance imaging : JMRI.
[17] T. Foster,et al. A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. , 1984, Medical physics.
[18] J. Best,et al. CHARACTERISATION OF ACUTE MYOCARDIAL INFARCTION BY GATED MAGNETIC RESONANCE IMAGING , 1985, The Lancet.
[19] R Deichmann,et al. T1 maps by K-space reduced snapshot-FLASH MRI. , 1992, Journal of computer assisted tomography.
[20] O. Simonetti,et al. An improved MR imaging technique for the visualization of myocardial infarction. , 2001, Radiology.
[21] P. Boesiger,et al. SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.
[22] A. Crawley,et al. A comparison of one‐shot and recovery methods in T1 imaging , 1988, Magnetic resonance in medicine.
[23] P Mansfield,et al. Optimization of the ultrafast Look-Locker echo-planar imaging T1 mapping sequence. , 1998, Magnetic resonance imaging.
[24] V. Faber,et al. THE TOXICITY OF CADMIUM , 1964, Lancet.