Complex Design Method of Filtration Station Considering Harmonic Components

The paper deals with a new methodology for calculating the filter parameters. The basis is respect for the fact that the real filter current consists of other harmonic components, which filter is tuned. The proposed methodology was used to design filters for traction substation 25 kV/50 Hz. The operation of the locomotives in the AC supply systems of 25 kV/50 Hz leads to a rising of higher order harmonic currents. Due to the 1-phase supply system, these are mainly the 3rd and 5th harmonics. By simulation and subsequent measurement of the proposed traction power station filters the proposed methodology was verified. Thus, the filter design can also be used for filter compensating stations of the standard 3-phase distribution network. The described method presents an optimal filter design without unnecessary oversizing. This fact reduces the size and cost of the filter. It is shown that it is possible to design a filter that meets the requirements for power quality under extreme load and to minimise distortion of line voltage.

[1]  Robert E Morrison,et al.  Voltage form factor control and reactive power compensation in a 25-kV electrified railway system using a shunt active filter based on voltage detection , 2003 .

[2]  C. Cecati,et al.  Design of H-bridge multilevel active rectifier for traction systems , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[3]  V. Toigo,et al.  Filter design for harmonic reduction in high-voltage booster for railway applications , 2005 .

[4]  Brian G. Stewart,et al.  Power Quality Measurement and Active Harmonic Power in 25 kV 50 Hz AC Railway Systems , 2020, Energies.

[5]  Fujun Ma,et al.  A Dual-Loop Control Strategy of Railway Static Power Regulator Under V/V Electric Traction System , 2011, IEEE Transactions on Power Electronics.

[6]  Fujun Ma,et al.  Railway Static Power Conditioners for High-speed Train Traction Power Supply Systems Using Three-phase V/V Transformers , 2011, IEEE Transactions on Power Electronics.

[7]  M. Aredes,et al.  A Shunt Active Power Filter Applied to High Voltage Distribution Lines , 1997, IEEE Power Engineering Review.

[8]  Zeliang Shu,et al.  Single-Phase Back-To-Back Converter for Active Power Balancing, Reactive Power Compensation, and Harmonic Filtering in Traction Power System , 2011, IEEE Transactions on Power Electronics.

[9]  P. W. Hammond A harmonic filter installation to reduce voltage distortion from static power converters , 1988 .

[10]  Zhengyou He,et al.  Passive Filter Design for China High-Speed Railway With Considering Harmonic Resonance and Characteristic Harmonics , 2015, IEEE Transactions on Power Delivery.

[11]  G.W. Chang,et al.  Modeling characteristics of harmonic currents generated by high-speed railway traction drive converters , 2004, IEEE Transactions on Power Delivery.