Portable flow-injection analyzer with liquid-core waveguide based fluorescence, luminescence, and long path length absorbance detector

We describe a multifunctional flow analysis instrument that is portable (25 cm × 20 cm × 11 cm, 2.3 kg) for facile field deployment. Using a 50 cm long Teflon ® AF tubing as final reaction and optical measurement conduit, we combine a liquid-core waveguide (LCW) based fluorescence detector that is transversely illuminated by an addressable light emitting diode array, a chemiluminescence (CL) detector and an absorbance detector with a solid-state broadband (400–700 nm) source. Several illustrative experiments have been carried out to test the performance of the instrument in different detection modes. A S/N = 3 limit of detection (LOD) of 0.25 gl −1 for chromium(VI) was established using the diphenylcarbazide chemistry, and an LOD of 5 gl −1 was similarly established for Al(III), using Pyrocatechol Violet (PCV) as the chelating chromogenic dye, in both cases using long path absorption detection. The LOD for aqueous hydrogen peroxide was 16 nM using a fluorescence method based on the formation of thiochrome from thiamine and 4 nM by a luminol chemiluminescence method. With a Nafion membrane diffusion scrubber (DS), the LOD was 8.0 pptv for gaseous hydrogen peroxide by the fluorescence method. © 2002 Elsevier Science B.V. All rights reserved.

[1]  P. Dasgupta,et al.  Transversely illuminated liquid core waveguide based fluorescence detection Fluorometric flow injection determination of aqueous ammonium/ammonia. , 1999, Talanta.

[2]  H. Franke,et al.  Liquid core waveguide with fiber optic coupling for remote pollution monitoring in the deep ultraviolet , 1998 .

[3]  Hilmar Franke,et al.  Optical fiber with a liquid H2O core , 1996, Photonics West.

[4]  Robert D. Waterbury,et al.  Determination of nanomolar concentrations of nitrite and nitrate in natural waters using long path length absorbance spectroscopy , 1998 .

[5]  E. Loree,et al.  Light emitting diode based flow-through optical absorption detectors. , 1993, Talanta.

[6]  P. Dasgupta,et al.  Determination of hexavalent chromium in leather extracts by the diphenylcarbazide (IUC-18) procedure: pitfalls and refinements , 2000 .

[7]  F. Krug,et al.  Merging zones in flow injection analysis: Part 3. Spectrophotometric determination of aluminium in plant and soil materials with sequential addition of pulsed reagents , 1979 .

[8]  Anthony. Anton,et al.  Colorimetric Estimation of Aluminum with Pyrocatechol Violet , 1960 .

[9]  J. Ruzicka,et al.  Sequential injection: a new concept for chemical sensors, process analysis and laboratory assays , 1990 .

[10]  Henryk Temkin,et al.  Deep Ultraviolet AlGaInN‐Based Light‐Emitting Diodes on Si(111) and Sapphire , 2002 .

[11]  J. Ruzicka,et al.  Flow injection analyses , 1975 .

[12]  P. Dasgupta,et al.  Chemiluminescence detection with a liquid core waveguide: Determination of ammonium with electrogenerated hypochlorite based on the luminol-hypochlorite reaction , 1999 .

[13]  R. Byrne,et al.  Long pathlength absorbance spectroscopy: trace analysis of Fe(II) using a 4.5m liquid core waveguide , 1997 .

[14]  H. Franke,et al.  A cylindrical liquid-core waveguide , 1996 .

[15]  P. Dasgupta,et al.  Continuous automated measurement of hexavalent chromium in airborne particulate matter. , 2001, Analytical chemistry.

[16]  P. Dasgupta,et al.  Dual-wavelength photometry with light emitting diodes. Compensation of refractive index and turbidity effects in flow-injection analysis , 1994 .

[17]  Purnendu K. Dasgupta,et al.  High-Sensitivity Gas Sensors Based on Gas-Permeable Liquid Core Waveguides and Long-Path Absorbance Detection , 1998 .

[18]  A. Bader,et al.  Detector cell based on plastic liquid-core waveguides suitable for aqueous solutions: one-to-two decades improved detection limits in conventional-size column liquid chromatography with absorption detection , 1998 .

[19]  M. Hutterli,et al.  Measurement of atmospheric formaldehyde with a diffusion scrubber and light‐emitting diode–liquid‐core waveguide based fluorometry , 2001 .

[20]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[21]  R. Byrne,et al.  Determination of trace chromium(VI) and molybdenum(VI) in natural and bottled mineral waters using long pathlength absorbance spectroscopy (LPAS). , 1999, Talanta.

[22]  Oddvar R⊘yset Flow-injection spectrophotometric determination of aluminium in water with pyrocatechol violet , 1986 .

[23]  E. Kaltenbacher,et al.  Construction of a compact spectrofluorometer/spectrophotometer system using a flexible liquid core waveguide. , 2000, Talanta.

[24]  H Franke,et al.  Water-core waveguide for pollution measurements in the deep ultraviolet. , 1998, Applied optics.

[25]  W. Baumann Optische Detektoren in der Flüssigkeits-Chromatographie , 1977 .

[26]  Andrew G. Glen,et al.  APPL , 2001 .

[27]  Waveguide Capillary Cell for Low-Refractive-Index Liquids , 1997 .

[28]  P. Dasgupta,et al.  Measurement of nitrogen dioxide and nitrous acid using gas-permeable liquid core waveguides , 2001 .

[29]  P. Dasgupta,et al.  Measurement of gaseous hydrogen peroxide with a liquid core waveguide chemiluminescence detector , 2001 .

[30]  Dasgupta,et al.  Measurement of atmospheric hydrogen peroxide and hydroxymethyl hydroperoxide with a diffusion scrubber and light emitting diode-liquid core waveguide-based fluorometry , 2000, Analytical chemistry.

[31]  Z. Fang,et al.  A miniaturized liquid core waveguide-capillary electrophoresis system with flow injection sample introduction and fluorometric detection using light-emitting diodes. , 2001, Analytical chemistry.