On-load measurement method for the reliability of distribution transformers

Transformer is the most important equipment used in power system. It's ensure network stability and reliability. Transformer fails over time due to several factors such as overload, poor insulation, cellulose deterioration, poor dielectric strength of the oil etc. However, transformer owners are finding it difficult to monitor the performance of distribution transformers (DT) in their place of application which results to system failure. Analyses of this distribution transformer performance required that distribution transformer be put on-load and the secondary terminals link to Power Quality and Energy Analyzer equipment (Fluke 435 Series II). This paper presents a methodology of carrying out experimental set up of on-load reliability measurements of the two distribution transformers, 500 kVA and 300 kVA, 11/0.415 kV as case study. Recommendations for the operations and maintenance engineers in charge to comply are discussed. This approach using the prescribed power quality equipment gives a reliable experimental method of evaluating the performance of distribution transformers. • Maintaining the selected distribution transformer on – load prior to and during the experiment. • The setting of experimental circuit to determine the operational parameters involving DT connection to Power Quality and Energy Analyzer (PQEA) equipment. • It utilize personal computer to download the measured parameters for graphical and statistics analysis.

[1]  C. S. Indulkar,et al.  Estimation of transmission line parameters from measurements , 2008 .

[2]  Vitor Hugo Ferreira,et al.  A survey on intelligent system application to fault diagnosis in electric power system transmission lines , 2016 .

[3]  Gary W. Chang,et al.  Power System Analysis , 1994 .

[4]  Muhammad H. Rashid,et al.  Power electronics handbook , 2001 .

[5]  T. O. Seppa A practical approach for increasing the thermal capabilities of transmission lines , 1993 .

[6]  T. O. Seppa,et al.  Accurate ampacity determination: temperature-sag model for operational real time ratings , 1995 .

[7]  Frank Fuller Fowle,et al.  Standard handbook for electrical engineers , 2012 .

[8]  F. I. Oluwajobi Effect of sag on transmission line , 2012 .

[9]  Mohammed k. Edan Effect of Unbalance Voltage on the Operation and Performance of a Three Phase Distribution Transformers , 2013 .

[10]  Jain Sandesh,et al.  Improve Power Factor and Reduce the Harmonics Distortion of the System , 2012 .

[11]  Sapna Khanchi,et al.  Power Factor Improvement of Induction Motor by Using Capacitors , 2013 .

[12]  Gehao Sheng,et al.  An approach for establishing key parameter system and evaluating the state of transmission line , 2015 .

[13]  R. Abd Allah Automatic Power Factor Correction Based on Alienation Technique , 2014 .

[14]  L. M. Adesina,et al.  WORK SPECIFICATION FOR THE CONSTRUCTION OF 33KV OVERHEAD LINES ACROSS A LAGOON USING EQUAL LEVEL DEAD-END LATTICE TOWER SUPPORTS , 2018 .

[16]  Susanne Ebersbach,et al.  Power System Analysis And Design , 2016 .