POST-IMPLEMENTATION OF AN AUTOMATIC TUBE SORTING AND REGISTRATION SYSTEM IN A CORE LABORATORY VE

Summary Bachground: Sample classification and registration have been recognized as important and time-consuming processes in laboratories. There is increasing pressure on laboratories to automate processes due to intense workload and reduce manual procedures and errors. The aim of the present study was to evaluate the positive effects of an automatic tube registration and sorting system on specimen processing. Methods: An automatic tube registration and sorting system (HCTS2000 MK2, m-u-t AG, Wedel, Germany) was evaluated. Turnaround time (TAT), rate of sample rejection and unrealized tests were examined 12 months pre- and post-implementation of the automatic tube sorting and registration system. Results: The mean TAT of routine chemistry immunoassay, complete blood cell count (CBC) and coagulation samples were significantly improved (P<0.001). The number of rejected samples and unrealized tests was insignificantly decreased post-implementation of the system (0.4% to 0.2% and 4.5% to 1.4%, respectively) (P>0.05). Conclusions: By reducing delays and errors in the preanalytical processing and sorting of samples, significant improvements in specimen processing were observed after implementation of the system. These results suggest that an automatic tube registration and sorting system may also be used to improve specimen processing in a higher-volume core laboratory. Kratak sadržaj Uvod: Klasifikacija i registracija uzoraka u laboratorijama prepoznate su kao važni i dugotrajni procesi. Laboratorije su pod sve većim pritiskom da automatizuju postupke zbog velikog obima posla i smanje manuelne procedure i greške. Cilj ove studije bio je da se procene pozitivni efekti jednog sistema za automatsko registrovanje i sortiranje uzoraka na njihovu obradu. Metode: Ocenjivali smo sistem za automatsko registrovanje i sortiranje uzoraka (HCTS2000 MK2, m-u-t AG, Wedel, Nemačka). Ukupno vreme za obradu uzorka (turnaround time), stopa odbacivanja uzorka i nerealizovani testovi obradeni su 12 meseci pre i posle implementacije sistema za automatsko sortiranje i registrovanje uzoraka. Rezultati: Srednje ukupno vreme obrade uzoraka za rutinske hemijske imunoeseje, kompletnu krvnu sliku i koagulaciju bilo je značajno bolje (P<0,001). Broj odbačenih uzoraka i nerealizovanih testova bio je smanjen, iako ne značajno, posle implementacije sistema (sa 0,4% na 0,2%, odnosno sa 4,5% na 1,4%) (P>0,05). Zaključak: Zahvaljujući ređim slučajevima kašnjenja i redim greškama prilikom preanalitičke obrade i sortiranja uzoraka, uočena su značajna poboljšanja u obradi uzoraka posle implementacije ovog sistema. Naši rezultati pokazuju da se sistemi za automatsko registrovanje i sortiranje mogu koristiti radi poboljšane obrade uzoraka i u centralnim laboratorijama sa velikim obimom posla.

[1]  Susan B. Garr,et al.  Automated transport and sorting system in a large reference laboratory: part 1. Evaluation of needs and alternatives and development of a plan. , 2002, Clinical chemistry.

[2]  Bassam Bishawi,et al.  Impact of a satellite laboratory on turnaround times for the emergency department , 2008, Clinical chemistry and laboratory medicine.

[3]  A T Chow,et al.  Application of existing technology to meet increasing demands for automated sample handling. , 1990, Clinical chemistry.

[4]  Giorgio Da Rin,et al.  Pre-analytical workstations: a tool for reducing laboratory errors. , 2009, Clinica chimica acta; international journal of clinical chemistry.

[5]  Susan B. Garr,et al.  Automated transport and sorting system in a large reference laboratory: part 2. Implementation of the system and performance measures over three years. , 2002, Clinical chemistry.

[6]  G E Hoffmann,et al.  Concepts for the third generation of laboratory systems. , 1998, Clinica chimica acta; international journal of clinical chemistry.

[7]  W. Korte,et al.  Advancing haemostasis automation – successful implementation of robotic centrifugation and sample processing in a tertiary service hospital , 2012, Clinical chemistry and laboratory medicine.

[8]  Blood sample tube transporting system versus point of care technology in an emergency department; effect on time from collection to reporting? A randomised trial , 2012, Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine.

[9]  L B Roberts Robotics in the medical laboratory. , 1991, Clinical chemistry.

[10]  J Büttner,et al.  [Evaluation of the diagnostic value of clinical chemical tests (author's transl)]. , 1977, Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie.

[11]  G. Lippi,et al.  Preanalytical variability: the dark side of the moon in laboratory testing / Präanalytische Variabilität: die Schattenseite klinischer Laboruntersuchungen , 2006 .

[12]  G. Lippi,et al.  Laboratory Diagnostics and Quality of Blood Collection , 2015, Journal of medical biochemistry.

[13]  S R Middleton Developing an automation concept that is right for your laboratory. , 2000, Clinical chemistry.

[14]  G. Lippi,et al.  Preanalytical variability: the dark side of the moon in laboratory testing , 2006, Clinical chemistry and laboratory medicine.

[15]  P. Manor,et al.  Turnaround times in the laboratory: a review of the literature. , 1999, Clinical laboratory science : journal of the American Society for Medical Technology.

[16]  D. Gill,et al.  Laboratory sample turnaround times: do they cause delays in the ED? , 2012, Journal of evaluation in clinical practice.

[17]  S. A. Whalen,et al.  Laboratory automation: trajectory, technology, and tactics. , 2000, Clinical chemistry.

[18]  H. Käser,et al.  Quantitative fluorimetric determination of urinary 3-methoxytyramine. , 1970, Clinica chimica acta; international journal of clinical chemistry.

[19]  Robin A Felder,et al.  Evaluation of an automated preanalytical robotic workstation at two academic health centers. , 2002, Clinical chemistry.

[20]  D. Aronsky,et al.  Decreasing lab turnaround time improves emergency department throughput and decreases emergency medical services diversion: a simulation model. , 2008, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[21]  Bhawna Singh,et al.  Turn Around Time (TAT) as a Benchmark of Laboratory Performance , 2010, Indian Journal of Clinical Biochemistry.

[22]  M. Moradi-Lakeh,et al.  Identifying causes of laboratory turnaround time delay in the emergency department. , 2012, Archives of Iranian medicine.