Evaluation of different disinfection calculation methods using CFD

Computational Fluid Dynamics combined with a particle tracking technique provides valuable information concerning residence times and contact times in chemical reactors. In drinking water treatment, for example an accurate estimation of the disinfection is important to predict the microbial safety. Ozone contactors are widely used for disinfection, but the complex geometry of the system causes suboptimal hydraulics and requires optimizations of the flow. This results in a lower ozone dosage, which may reduce the formation of unwanted disinfection-by-products and the consumption of energy. To that end disinfection needs to be calculated precisely, accounting for the complex hydraulics. Several calculation methods estimating the disinfection performance of ozone contactors were evaluated using Computational Fluid Dynamics. For an accurate disinfection prediction, the full distribution of ozone exposures (CT values) is needed, only a mean CT value or residence time distribution provides insufficient information for an accurate disinfection prediction. Adjustments to the geometry of the ozone contactor that reduce the short-circuit flows resulted in an increase in disinfection capacity, whereas the mean CT value remained the same. A sensitivity analysis with respect to the kinetics was conducted. The gain in disinfection capacity obtained by optimizing the hydraulics was significant for typical values used in practice.

[1]  S. Craik,et al.  Effect of Micro-Mixing Conditions on Predictions of Cryptosporidium Inactivation in an Ozone Contactor , 2005 .

[2]  Th.N. Zwietering The degree of mixing in continuous flow systems , 1959 .

[3]  Benito Jose Marinas,et al.  Inactivation of Cryptosporidium parvum oocysts with ozone , 1999 .

[4]  Jun Ma,et al.  Application of computational fluid dynamics (CFD) to ozone contactor optimization , 2006 .

[5]  Peter M. Huck,et al.  A Computational Fluid Dynamics Based Integrated Disinfection Design Approach for Improvement of Full-scale Ozone Contactor Performance , 2007 .

[6]  Spyros Andronopoulos,et al.  Optimization of the numerical algorithms of the ADREA-I mesoscale prognostic meteorological model for real-time applications , 2008, Environ. Model. Softw..

[7]  Bakhtier Farouk,et al.  Computational Fluid Dynamics Analysis of the Effects of Reactor Configuration on Disinfection Efficiency , 2006, Water environment research : a research publication of the Water Environment Federation.

[8]  Desmond F. Lawler,et al.  An enhanced tanks-in-series model for interpretation of tracer tests , 2005 .

[9]  L C Rietveld,et al.  Inactivation of Escherichia coli by ozone under bench-scale plug flow and full-scale hydraulic conditions. , 2006, Water research.

[10]  Joel J. Ducoste,et al.  Alternative Approaches to Modeling Fluence Distribution and Microbial Inactivation in Ultraviolet Reactors: Lagrangian versus Eulerian , 2005 .

[11]  Steve Via,et al.  Cryptosporidium Log-inactivation with Ozone Using Effluent CT10, Geometric Mean CT10, Extended Integrated CT10 and Extended CSTR Calculations , 2005 .

[12]  G. Stelling,et al.  Residence Time Distributions in Ozone Contactors , 2008 .

[13]  Efisio Solazzo,et al.  Improved parameterisation for the numerical modelling of air pollution within an urban street canyon , 2009, Environ. Model. Softw..

[14]  Karim Essemiani,et al.  Hydraulic study and optimisation of water treatment processes using numerical simulation , 2002 .

[15]  P.W.M.H. Smeets,et al.  Modeling of Ozonation for Dissolved Ozone Dosing , 2007 .

[16]  F. Taghipour,et al.  UV reactor performance modeling by Eulerian and Lagrangian methods. , 2006, Environmental science & technology.

[17]  David J. Hiltebrand,et al.  Guidance Manual for Compliance with the Filtration and Disinfection Requirements for Public Water Systems Using Surface Water Sources , 1991 .

[18]  Joel J. Ducoste,et al.  The integrated disinfection design framework approach to reactor hydraulics characterization , 2001 .

[19]  Z. Do-Quang,et al.  Use of computational fluid dynamics for simulating hydrodynamics and mass transfer in industrial ozonation towers , 1999 .

[20]  Jónas Elíasson,et al.  Large hazardous floods as translatory waves , 2007, Environ. Model. Softw..

[21]  Garth N. Wells,et al.  A Galerkin interface stabilisation method for the advection–diffusion and incompressible Navier–Stokes equations , 2007 .

[22]  Yanjin Liu,et al.  Numerical simulation of chloramines formation in turbulent flow using a multi-fluid micromixing model , 2006, Environ. Model. Softw..