Best approach for prostate cancer detection: a prospective study on transperineal versus transrectal six-core prostate biopsy.

OBJECTIVES To compare the efficacy of transperineal versus transrectal six-core prostate biopsy. Transrectal sextant biopsy is the most common method for prostate cancer detection. However, the cancer detection rate with this technique is increasingly considered inadequate. Different prostate biopsy procedures, mainly based on addition of additional transrectal cores to traditional sextant biopsy, have been proposed to increase the cancer diagnosis rate. The efficacy of the transperineal approach has not yet been fully established. METHODS In a prospective study, 107 patients with elevated prostate-specific antigen levels (greater than 4.0 ng/mL) underwent prostate biopsy with six transperineal cores, using a "fan" scheme, plus six transrectal cores, according to the sextant technique. The median prostate-specific antigen level was 8.2 ng/mL (range 4.1 to 240). RESULTS The overall cancer detection rate was 40% (43 of 107); prostate cancer was found in 38% (41 of 107) of patients with the transperineal approach and in 32% (34 of 107) of patients with the transrectal approach. Of 43 diagnosed cancers, 41 (95%) were found with the transperineal approach and 34 (79%) with the transrectal approach (P = 0.012). No patient had low-grade cancer (Gleason score 2 to 4), 25 patients had intermediate-grade cancer (Gleason score 5 to 6), and 18 patients had high-grade cancer (Gleason score 7 to 10). CONCLUSIONS This is the first report comparing in vivo two different approaches to prostate biopsy. Transperineal biopsy seems superior to transrectal biopsy to detect prostate cancer. Both the transperineal and the transrectal approach should be familiar to the urologist who needs to obtain an adequate cancer detection rate. Transrectal sextant biopsy cannot be considered the standard technique for prostate cancer detection.

[1]  J. Gore,et al.  Optimal combinations of systematic sextant and laterally directed biopsies for the detection of prostate cancer. , 2001, The Journal of urology.

[2]  V. Pansadoro,et al.  The value of a single biopsy with 12 transperineal cores for detecting prostate cancer in patients with elevated prostate specific antigen. , 2001, The Journal of urology.

[3]  W. Kirkels,et al.  The changing pattern of prostate cancer at the time of diagnosis: characteristics of screen detected prostate cancer in a population based screening study. , 1999, The Journal of urology.

[4]  M. Miller,et al.  Observations on pathology trends in 62,537 prostate biopsies obtained from urology private practices in the United States. , 1998, Urology.

[5]  S. Ishidoya,et al.  [Screening of prostate cancer with PSA and transperineal six sextant biopsy]. , 1999, Nihon Hinyokika Gakkai zasshi. The japanese journal of urology.

[6]  P. Young,et al.  Systematic transperineal ultrasound guided template biopsy of the prostate in patients at high risk. , 2001, The Journal of urology.

[7]  E. Metter,et al.  Today men with prostate cancer have larger prostates. , 2000, Urology.

[8]  S. Cytron,et al.  A comparison between digitally-guided fine needle aspiration and ultrasound-guided transperineal core needle biopsy of the prostate for the detection of prostate cancer. , 1994, British journal of urology.

[9]  T. H. van der Kwast,et al.  Detection of prostate cancer: a comparative study of the diagnostic efficacy of sextant transrectal versus sextant transperineal biopsy. , 2000, Urology.

[10]  M. Terris,et al.  Limitations of transperineal ultrasound-guided prostate biopsies. , 1999, Urology.

[11]  D. Johnston,et al.  A comparative analysis of sextant and an extended 11-core multisite directed biopsy strategy. , 2000, The Journal of urology.

[12]  C Busch,et al.  Modeling prostate cancer distributions. , 1999, Urology.

[13]  D L McCullough,et al.  Systematic 5 region prostate biopsy is superior to sextant method for diagnosing carcinoma of the prostate. , 1997, The Journal of urology.

[14]  H. Klingler,et al.  Comparative Study of Two Different TRUS–Guided Sextant Biopsy Techniques in Detecting Prostate Cancer in One Biopsy Session , 2000, European Urology.

[15]  J. Fracchia,et al.  Periprostatic nerve blockade for transrectal ultrasound guided biopsy of the prostate: a randomized, double-blind, placebo controlled study. , 2001, The Journal of urology.

[16]  R. Clements,et al.  Experience with ultrasound guided transperineal prostatic needle biopsy 1985-1988. , 1990, British journal of urology.

[17]  K. Shinohara,et al.  The optimal systematic prostate biopsy scheme should include 8 rather than 6 biopsies: results of a prospective clinical trial. , 2000, The Journal of urology.

[18]  M. Terris,et al.  Random systematic versus directed ultrasound guided transrectal core biopsies of the prostate. , 1989, The Journal of urology.

[19]  M. Terris,et al.  Critical evaluation of the current indications for transition zone biopsies. , 2001, Urology.

[20]  K C Shandera,et al.  Variability in patient preparation for prostate biopsy among American urologists. , 1998, Urology.

[21]  F. Schröder,et al.  Detection of prostate cancer. , 1995, BMJ.

[22]  P. Mouriquand,et al.  The significance of the prostatic hypoechoic area: results in 226 ultrasonically guided prostatic biopsies. , 1990, The Journal of urology.