Correction of conebeam CT values using a planning CT for derivation of the "dose of the day".

BACKGROUND AND PURPOSE Verification of the actually delivered 3D dose distribution during each treatment fraction ("dose of the day") is the most complete and clinical relevant "in-vivo" check of an IMRT treatment. To do this, during patient treatment portal dose images are routinely acquired with our electronic portal imaging device to derive the delivered fluence map for each treatment field. In addition, a conebeam CT scan is acquired just prior to treatment to derive the patient geometry at the time of treatment. However, the use of conebeam CT scans for dose calculation is hampered by inaccuracies in the conversion of CT values to electron densities due to an enlarged scatter contribution. MATERIALS AND METHODS In this work, a method is described for mapping of Hounsfield Units of the planning CT to the conebeam CT scan, while accounting for non-rigidity in the anatomy, e.g. related to weight loss, in an approximate way. The method was validated for head and neck cancer patients by comparing dose distributions calculated using adjusted Hounsfield Units with a golden standard. RESULTS AND CONCLUSIONS The observed dose differences were less than 1% in the majority of points, and in at least 96% of the points a 3D gamma analysis resulted in gamma values of less than 1 when applying a 2%/2mm criterion, showing that this straightforward approach allows for an accurate dose calculation based on conebeam CT scans.

[1]  Maarten L P Dirkx,et al.  Fast and accurate leaf verification for dynamic multileaf collimation using an electronic portal imaging device. , 2002, Medical physics.

[2]  D. Jaffray,et al.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter. , 2001, Medical physics.

[3]  Ping Xia,et al.  Dose calculation using megavoltage cone-beam CT. , 2007, International journal of radiation oncology, biology, physics.

[4]  D. Low,et al.  A technique for the quantitative evaluation of dose distributions. , 1998, Medical physics.

[5]  David A Jaffray,et al.  Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy. , 2006, Medical physics.

[6]  David A Jaffray,et al.  Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: image quality and system performance. , 2007, International journal of radiation oncology, biology, physics.

[7]  V. Khoo,et al.  X-ray volumetric imaging in image-guided radiotherapy: the new standard in on-treatment imaging. , 2006, International journal of radiation oncology, biology, physics.

[8]  Ruola Ning,et al.  X-ray scatter correction algorithm for cone beam CT imaging. , 2004, Medical physics.

[9]  Lei Xing,et al.  Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation , 2007, Physics in medicine and biology.

[10]  B. Heijmen,et al.  3D dose reconstruction for clinical evaluation of IMRT pretreatment verification with an EPID. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  B. Heijmen,et al.  SIFT: a method to verify the IMRT fluence delivered during patient treatment using an electronic portal imaging device. , 2004, International journal of radiation oncology, biology, physics.

[12]  S. Richard,et al.  A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT. , 2005, Medical physics.

[13]  Maarten L P Dirkx,et al.  Dosimetric pre-treatment verification of IMRT using an EPID; clinical experience. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  Jan Hrbacek,et al.  Cone-beam CT Hounsfield unit correction method and application on images of the pelvic region , 2006 .

[15]  Fang-Fang Yin,et al.  Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning. , 2006, International journal of radiation oncology, biology, physics.

[16]  Maarten L P Dirkx,et al.  Fast, daily linac verification for segmented IMRT using electronic portal imaging. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  A. Niemierko Reporting and analyzing dose distributions: a concept of equivalent uniform dose. , 1997, Medical physics.