Improving highly accelerated fat fraction measurements for clinical trials in muscular dystrophy: origin and quantitative effect of R2* changes.

Purpose To investigate the effect of R2* modeling in conventional and accelerated measurements of skeletal muscle fat fraction in control subjects and patients with muscular dystrophy. Materials and Methods Eight patients with Becker muscular dystrophy and eight matched control subjects were recruited with approval from the Newcastle and North Tyneside 2 Research Ethics Committee and with written consent. Chemical-shift images with six widely spaced echo times (in 3.5-msec increments) were acquired to correlate R2* and muscle fat fraction. The effect of incorporating or neglecting R2* modeling on fat fraction magnitude and variance was evaluated in a typical three-echo protocol (with 0.78-msec increments). Accelerated acquisitions with this protocol with 3.65×, 4.94×, and 6.42× undersampling were reconstructed by using combined compressed sensing and parallel imaging and fat fraction maps produced with R2* modeling. Results Muscle R2* at 3.0 T (33-125 sec(-1)) depended on the morphology of fat replacement, the highest values occurring with the greatest interdigitation of fat. The inclusion of R2* modeling removed bias, which was greatest at low fat fraction, but did not increase variance. The 95% limits of agreement of the accelerated acquisitions were tight and not degraded by R2* modeling (1.65%, 1.95%, and 2.22% for 3.65×, 4.94×, and 6.42× acceleration, respectively). Conclusion Incorporating R2* modeling prevents systematic errors in muscle fat fraction by up to 3.5% without loss of precision and should be incorporated into all muscular dystrophy studies. Fat fraction measurements can be accelerated fivefold by using combined compressed sensing and parallel imaging, modeling for R2* without loss of fidelity.

[1]  M. Gaeta,et al.  Muscle fat-fraction and mapping in Duchenne muscular dystrophy: evaluation of disease distribution and correlation with clinical assessments , 2012, Skeletal Radiology.

[2]  O. Bieri,et al.  Quantitative MRI and loss of free ambulation in Duchenne muscular dystrophy , 2013, Journal of Neurology.

[3]  S. Reeder,et al.  Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise , 2007, Magnetic resonance in medicine.

[4]  Jacob D Willig-Onwuachi,et al.  R2* ‐corrected water–fat imaging using compressed sensing and parallel imaging , 2014, Magnetic resonance in medicine.

[5]  T. Wren,et al.  Heterogeneity of muscle fat infiltration in children with spina bifida. , 2014, Research in developmental disabilities.

[6]  Jasper M. Morrow,et al.  Quantitative Muscle MRI as an Assessment Tool for Monitoring Disease Progression in LGMD2I: A Multicentre Longitudinal Study , 2013, PloS one.

[7]  M. Versluis,et al.  Quantitative MRI and strength measurements in the assessment of muscle quality in Duchenne muscular dystrophy , 2014, Neuromuscular Disorders.

[8]  Diego Hernando,et al.  Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithm , 2009, Magnetic resonance in medicine.

[9]  Alexey Samsonov,et al.  Independent estimation of T*2 for water and fat for improved accuracy of fat quantification , 2010, Magnetic resonance in medicine.

[10]  H. Völzke,et al.  Effect of multipeak spectral modeling of fat for liver iron and fat quantification: correlation of biopsy with MR imaging results. , 2012, Radiology.

[11]  M. Gaeta,et al.  Muscle fat fraction in neuromuscular disorders: dual-echo dual-flip-angle spoiled gradient-recalled MR imaging technique for quantification--a feasibility study. , 2011, Radiology.

[12]  M. Wood,et al.  Clinical trials using antisense oligonucleotides in duchenne muscular dystrophy. , 2013, Human gene therapy.

[13]  C. Sirlin,et al.  In vivo characterization of the liver fat 1H MR spectrum , 2011, NMR in biomedicine.

[14]  Krista Vandenborne,et al.  Chemical shift‐based MRI to measure fat fractions in dystrophic skeletal muscle , 2014, Magnetic resonance in medicine.

[15]  Huanzhou Yu,et al.  On the performance of T2* correction methods for quantification of hepatic fat content , 2012, Magnetic resonance in medicine.

[16]  Jeffrey Tsao,et al.  Hierarchical IDEAL: Fast, robust, and multiresolution separation of multiple chemical species from multiple echo times , 2013, Magnetic resonance in medicine.

[17]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[18]  H. Kan,et al.  Quantitative proton MR techniques for measuring fat , 2013, NMR in biomedicine.

[19]  A. Mayhew,et al.  Quantitative Magnetic Resonance Imaging in Limb-Girdle Muscular Dystrophy 2I: A Multinational Cross-Sectional Study , 2014, PloS one.

[20]  S. Reeder,et al.  Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy , 2011, Journal of magnetic resonance imaging : JMRI.

[21]  Peter Börnert,et al.  ISMRM workshop on fat–water separation: Insights, applications and progress in MRI , 2012, Magnetic resonance in medicine.

[22]  R. Idilman,et al.  Hepatic steatosis: quantification by proton density fat fraction with MR imaging versus liver biopsy. , 2013, Radiology.

[23]  Volker Straub,et al.  Towards harmonization of protocols for MRI outcome measures in skeletal muscle studies: Consensus recommendations from two TREAT-NMD NMR workshops, 2 May 2010, Stockholm, Sweden, 1–2 October 2009, Paris, France , 2012, Neuromuscular Disorders.

[24]  M. Reijnierse,et al.  Comparison of dixon and T1‐weighted MR methods to assess the degree of fat infiltration in duchenne muscular dystrophy patients , 2013, Journal of magnetic resonance imaging : JMRI.

[25]  O. Bieri,et al.  Quantitative MRI can detect subclinical disease progression in muscular dystrophy , 2012, Journal of Neurology.

[26]  S. Majumdar,et al.  Characterization of the regional distribution of skeletal muscle adipose tissue in type 2 diabetes using chemical shift‐based water/fat separation , 2012, Journal of magnetic resonance imaging : JMRI.

[27]  S. Reeder,et al.  Comparison of R2* correction methods for accurate fat quantification in fatty liver , 2013, Journal of magnetic resonance imaging : JMRI.

[28]  L. Nardo,et al.  Quantitative assessment of fat infiltration in the rotator cuff muscles using water‐fat MRI , 2014, Journal of magnetic resonance imaging : JMRI.

[29]  Huanzhou Yu,et al.  Estimation of liver T*2 in transfusion‐related iron overload in patients with weighted least squares T*2 IDEAL , 2012, Magnetic resonance in medicine.

[30]  Michael Elad,et al.  ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA , 2014, Magnetic resonance in medicine.

[31]  Volker Straub,et al.  Investigating the quantitative fidelity of prospectively undersampled chemical shift imaging in muscular dystrophy with compressed sensing and parallel imaging reconstruction , 2014, Magnetic resonance in medicine.