A case of occupational internal contamination with 241Am.

An internal contamination with (241)Am was detected in a worker during a routine monitoring of workers from a company producing Am sources for smoke detectors and Am-Be neutron sources. During the 4-year period after the exposure, the number of urine and faecal samples from the worker were analysed; in vivo measurements were also performed. Specific values for absorption parameters of the human respiratory tract model and particle transport values were applied to improve the model fit to the measurement data. A good agreement of the bioassay data with the so-modified model predictions was obtained.

[1]  T. Vrba Head calibration phantoms for actinides: measurements and simulations. , 2011, Radiation protection dosimetry.

[2]  I. Malátová,et al.  Evaluation of committed effective doses from internal contamination of 241Am using experimentally determined parameters of the contaminant. , 2007, Radiation protection dosimetry.

[3]  J. Eikenberg,et al.  Twenty-year follow-up of a Pu/Am inhalation case. , 2006, Radiation protection dosimetry.

[4]  I. Malatova,et al.  General guidelines for the estimation of committed effective dose from incorporation monitoring data : (Project IDEAS - EU contract no. FIKR-CT2001-00160) , 2006 .

[5]  D P Hickman,et al.  LLNL Torso Phantom Assembly and Disassembly , 2005 .

[6]  I. Malátová,et al.  Contamination of seven workers with 241Am , 2005 .

[7]  M. Bailey,et al.  A step-by-step procedure to aid the assessment of intake and doses from measurement data. , 2005, Radiation protection dosimetry.

[8]  R. Bull,et al.  An intake of americum oxide powder: Implications for biokinetic models for americum , 2003 .

[9]  R. Traub,et al.  SIX-YEAR FOLLOW-UP OF AN ACUTE 241Am INHALATION INTAKE , 2003, Health physics.

[10]  R. Bull,et al.  An intake of americium oxide powder: implications for biokinetic models for americium. , 2003, Radiation protection dosimetry.

[11]  K. Simkiss,et al.  Overview and Perspective , 1989 .

[12]  N. Cohen,et al.  Reconstruction of a human skull calibration phantom using bone sections from an 241Am exposure case. , 1988, Health physics.

[13]  R. Kathren,et al.  Macrodistribution of plutonium and americium in four human skeletons , 1988 .

[14]  R. Thompson 1976 Hanford americium exposure incident: overview and perspective. , 1983, Health physics.

[15]  Fryer Fa Long-term retention of americium-241 following accidental inhalation. , 1976 .

[16]  F. Fry Long-term retention of americium-241 following accidental inhalation. , 1976, Health physics.