Computational model of the fluid dynamics of a cannula inserted in a vessel: incidence of the presence of side holes in blood flow.

Vascular access methods, performed by the insertion of cannulae into vessels, may disturb the physiological flow of blood, giving rise to non-physiological pressure variations and shear stresses. To date, the hydrodynamic behaviour of the cannulae has been evaluated comparing their pressure loss-flow rate relationships, as obtained from in vitro experiments using a monodimensional approach; this methodology neither furnish information about the local fluid dynamics nor the established flow field in specific clinical work conditions. Since the shear stress is a critical factor in the design of artificial circulatory devices, more knowledge should be necessary about the local values assumed by the haemodynamic parameters during cannulation. An alternative way to investigate the fluid dynamic as accurately as possible is given by numeric studies. A 3D model of cannula concentrically placed in a rigid wall vessel is presented, with the finite element methodology used to numerically simulate the steady-state flow field in two different venous cannulation case studies, with two cannulae having a central hole and two or four side holes, respectively, with the same boundary conditions. Lower velocity and shear stress peak values have been computed for the model with four side holes upstream of the central hole, in the region of the cannula where the inlet flows meet and towards cannula's outlet, due to the increased flow symmetry and inlet area with respect to the model with two side holes. Starting from the investigation of different cannula designs, numerically assessing the local fluid dynamics, indications can be drawn to support both the design phase and the device optimal clinical use, in order to limit risks of biomechanical origin. Thus the presence of four side holes implied, as a consequence of the greater inlet area and of the increased symmetry, a less disturbed blood flow, together with reduced shear stress values. Furthermore, results show that the numerical simulations furnished useful informations on the interaction between vessel and cannula, e.g. on the fluid dynamics establishing in the free luminal space left, in the vessel, by the inserted cannula.

[1]  L. Chua,et al.  The flow patterns within the impeller passages of a centrifugal blood pump model. , 2000, Medical engineering & physics.

[2]  J F Antaki,et al.  A mathematical model for shear-induced hemolysis. , 1995, Artificial organs.

[3]  M Borow,et al.  Evaluation of Central Venous Catheter Thrombogenicity , 1985, Acta anaesthesiologica Scandinavica. Supplementum.

[4]  H. Reul,et al.  Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - in Vitro Comparison of 25 Aortic Valves , 1990, The International journal of artificial organs.

[5]  Yarborough Ka,et al.  Hydrodynamic hemolysis in extracorporeal machines. , 1966 .

[6]  F. Grover,et al.  Comparison of flow differences among venous cannulas. , 1983, The Annals of thoracic surgery.

[7]  C Bludszuweit,et al.  Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump. , 1995, Artificial organs.

[8]  U. Steinseifer,et al.  In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves. , 1993, The Journal of thoracic and cardiovascular surgery.

[9]  D. Williams,et al.  Influence of wall shear rate on parameters of blood compatibility of intravascular catheters. , 1996, Biomaterials.

[10]  M Grigioni,et al.  On the monodimensional approach to the estimation of the highest reynolds shear stress in a turbulent flow. , 2000, Journal of biomechanics.

[11]  H Reul,et al.  Velocities, Shear Stresses and Blood Damage Potential of the Leakage Jets of the Medtronic Parallel™ Bileaflet Valve , 2000, The International journal of artificial organs.

[12]  P. Raviart Finite element methods and Navier-Stokes equations , 1979 .

[13]  R. T. Hart,et al.  Computer simulations in biomedicine , 1996 .

[14]  Shu Chien,et al.  Handbook of Bioengineering , 1986 .

[15]  Kenneth A. Solen,et al.  Formation of Occlusive Platelet Aggregates in Whole Blood Caused by Low Concentrations of ADP , 2000, ASAIO journal.

[16]  J. Riley,et al.  In vitro comparison of cavoatrial (dual stage) cannulae for use during cardiopulmonary bypass , 1986 .

[17]  J D Hellums,et al.  Morphological, biochemical, and functional changes in human platelets subjected to shear stress. , 1975, The Journal of laboratory and clinical medicine.

[18]  E F Bernstein,et al.  Sublethal Damage to the Red Blood Cell from Pumping , 1967, Circulation.

[19]  J. Feijen,et al.  An in vitro study of the adhesion of blood platelets onto vascular catheters. Part I. , 1987, Journal of biomedical materials research.

[20]  Pascal Verdonck,et al.  Red Cell Injury Assessed in a Numeric Model of a Peripheral Dialysis Needle , 1996 .

[21]  N H Hwang,et al.  Human red blood cell hemolysis in a turbulent shear flow: contribution of Reynolds shear stresses. , 1984, Biorheology.

[22]  J. Joist,et al.  Potentiation by red blood cells of shear-induced platelet aggregation: relative importance of chemical and physical mechanisms , 1984 .

[23]  H Reul,et al.  Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics. , 2001, Artificial organs.

[24]  G Jayaraman,et al.  Flow in a catheterized curved artery with stenosis. , 1999, Journal of biomechanics.

[25]  R. Bartlett,et al.  A Standardized System for Describing Flow/Pressure Relationships in Vascular Access Devices , 1991, ASAIO transactions.

[26]  V. Barbaro,et al.  Laser Doppler Anemometry Study of Bidimensional Flows Downstream of Three 19 mm Bileaflet Valves in the Mitral Position, Under Kinematic Similarity , 2000, Annals of Biomedical Engineering.

[27]  Ajit P. Yoganathan,et al.  Experimental Investigation of the Steady Flow Downstream of the St. Jude Bileaflet Heart Valve: A Comparison Between Laser Doppler Velocimetry and Particle Image Velocimetry Techniques , 2004, Annals of Biomedical Engineering.

[28]  W Bedingham,et al.  Application of finite element analysis for assessing biocompatibility of intra-arterial catheters and probes. , 1991, ASAIO transactions.

[29]  H. Pettersson,et al.  Hydro- and Hemodynamic Effects of Catheterization of Vessels , 1977, Acta radiologica: diagnosis.

[30]  G. V. Van Nooten,et al.  Hydrodynamical Comparison of Aortic Arch Cannulae , 1998, The International journal of artificial organs.

[31]  A. Leuprecht,et al.  Computer Simulation of Non-Newtonian Effects on Blood Flow in Large Arteries , 2001, Computer methods in biomechanics and biomedical engineering.

[32]  D. A. Mcdonald Blood flow in arteries , 1974 .