A Mixed-Signal Spectroscopic-Grade and High-Functionality CMOS Readout Cell for Semiconductor X-$\gamma$ Ray Pixel Detectors

We present a mixed-signal CMOS front-end cell designed for semiconductor pixel detectors for X-gamma ray imaging and spectroscopy. The readout pixel cell (RPC) comprises an analog and a digital section to accomplish all the functionality of a spectroscopic-grade signal readout. The analog section includes a low noise charge preamplifier, a two stage shaper amplifier with digitally selectable shaping times from 1 mus to 10 mus, a baseline restorer, a high precision peak stretcher and an output amplifier. The digital section includes an amplitude discriminator with coarse and fine digital control of the threshold level, a peak discriminator, a current-mode trigger generator, a logic circuit to accomplish the pulse pile-up rejection and the RPC reset after the A/D conversion, the disable functions of the preamplifier and of the discriminators. The RPC has been designed and manufactured in 0.35 mum CMOS technology with a size of 300 mumtimes300 mum. The full functionality of the RPC has been successfully tested. At room temperature, the intrinsic equivalent noise charge is 15.7 electrons r.m.s. at 3.3 mus and the minimum noise slope is 22 electrons/pF at 8 mus, the linearity error is between -1.4% and +1.2% within 1.9 fC input signal dynamic. The RPC has separate voltage supplies (+3.3 V) and grounds for the analog and digital sections and the total power consumption is 495 muW.

[1]  Marco Sampietro,et al.  ‘R-lens filter’: An (RC)n current-mode lowpass filter , 1999 .

[3]  Selcuk Cihangir and Simon Kwan,et al.  Characterization of indium and solder bump bonding for pixel detectors , 2000 .

[4]  Marcos Bavdaz,et al.  Hard X-ray test and evaluation of a prototype 32 32 pixel gallium-arsenide array , 2002 .

[5]  Aleksey E. Bolotnikov,et al.  High resolution CdZnTe pixel detectors with VLSI readout , 1999 .

[6]  Giuseppe Bertuccio,et al.  Progress in ultra-low-noise ASICs for radiation detectors , 2007 .

[7]  G. De Geronimo,et al.  A CMOS fully compensated continuous reset system , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[8]  F. Borghetti,et al.  An integrated reset / pulse pile-up rejection circuit for pixel readout ASIC's , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[9]  K. Hurley,et al.  Preliminary test results of pixel detectors developed for the All-sky X-ray and Gamma-ray Astronomy Monitor (AXGAM) , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[10]  G. Bertuccio,et al.  A compact VLSI dc restorer for multichannel X-/spl gamma/ ray detectors , 2005, IEEE Transactions on Nuclear Science.

[11]  Marco Sampietro,et al.  Zero-power current conveyor for DC stabilisation and system reset of fast current pulse amplifiers , 1998 .

[12]  B. Krieger,et al.  An 8/spl times/8 pixel IC for X-ray spectroscopy , 2001 .

[13]  R. Dinapoli,et al.  Medipix2: A 64-k pixel readout chip with 55-/spl mu/m square elements working in single photon counting mode , 2001 .