Machine learning applied to multi-sensor information to reduce false alarm rate in the ICU

Studies reveal that the false alarm rate (FAR) demonstrated by intensive care unit (ICU) vital signs monitors ranges from 0.72 to 0.99. We applied machine learning (ML) to ICU multi-sensor information to imitate a medical specialist in diagnosing patient condition. We hypothesized that applying this data-driven approach to medical monitors will help reduce the FAR even when data from sensors are missing. An expert-based rules algorithm identified and tagged in our dataset seven clinical alarm scenarios. We compared a random forest (RF) ML model trained using the tagged data, where parameters (e.g., heart rate or blood pressure) were (deliberately) removed, in detecting ICU signals with the full expert-based rules (FER), our ground truth, and partial expert-based rules (PER), missing these parameters. When all alarm scenarios were examined, RF and FER were almost identical. However, in the absence of one to three parameters, RF maintained its values of the Youden index (0.94–0.97) and positive predictive value (PPV) (0.98–0.99), whereas PER lost its value (0.54–0.8 and 0.76–0.88, respectively). While the FAR for PER with missing parameters was 0.17–0.39, it was only 0.01–0.02 for RF. When scenarios were examined separately, RF showed clear superiority in almost all combinations of scenarios and numbers of missing parameters. When sensor data are missing, specialist performance worsens with the number of missing parameters, whereas the RF model attains high accuracy and low FAR due to its ability to fuse information from available sensors, compensating for missing parameters.

[1]  J Edworthy,et al.  The design and implementation of non-verbal auditory warnings. , 1994, Applied ergonomics.

[2]  D. Altman,et al.  Statistics Notes: Diagnostic tests 2: predictive values , 1994, BMJ.

[3]  Top 10 health technology hazards for 2013. , 2012, Health devices.

[4]  Yuval Bitan,et al.  Correlating data from different sensors to increase the positive predictive value of alarms: an empiric assessment , 2012, F1000Research.

[5]  M. Cvach Monitor alarm fatigue: an integrative review. , 2012, Biomedical instrumentation & technology.

[6]  Andy Liaw,et al.  Classification and Regression by randomForest , 2007 .

[7]  Qiao Li,et al.  The PhysioNet/Computing in Cardiology Challenge 2015: Reducing false arrhythmia alarms in the ICU , 2015, 2015 Computing in Cardiology Conference (CinC).

[8]  Alexander Dekhtyar,et al.  Information Retrieval , 2018, Lecture Notes in Computer Science.

[9]  R. Califf,et al.  Practice Standards for Electrocardiographic Monitoring in Hospital Settings: An American Heart Association Scientific Statement From the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young , 2004, Circulation.

[10]  Elie Azoulay,et al.  Reporting and handling missing values in clinical studies in intensive care units , 2013, Intensive Care Medicine.

[11]  M. Funk,et al.  Alarm fatigue: a patient safety concern. , 2013, AACN advanced critical care.

[12]  Linda M. Eerikäinen,et al.  Reduction of false arrhythmia alarms using signal selection and machine learning , 2016, Physiological measurement.

[13]  Robert D. Sorkin,et al.  FORUM: Why are people turning off our alarms? , 1988 .

[14]  B. Drew,et al.  Insights into the Problem of Alarm Fatigue with Physiologic Monitor Devices: A Comprehensive Observational Study of Consecutive Intensive Care Unit Patients , 2014, PloS one.

[15]  Bo Yang,et al.  Reducing false arrhythmia alarms in the ICU , 2015, 2015 Computing in Cardiology Conference (CinC).

[16]  Abdul Ghaaliq Lalkhen,et al.  Clinical tests: sensitivity and specificity , 2008 .

[17]  B. Brew,et al.  Involvement of the Kynurenine Pathway in Human Glioma Pathophysiology , 2014, PloS one.

[18]  George B Moody,et al.  The PhysioNet/computing in cardiology challenge 2010: Mind the gap , 2010, 2010 Computing in Cardiology.

[19]  Leo Breiman,et al.  Classification and Regression Trees , 1984 .

[20]  Hui-Min Xie,et al.  Clinical review: The impact of noise on patients' sleep and the effectiveness of noise reduction strategies in intensive care units , 2009, Critical care.

[21]  Nasser M. Nasrabadi,et al.  Pattern Recognition and Machine Learning , 2006, Technometrics.

[22]  M. Imhoff,et al.  Alarm Algorithms in Critical Care Monitoring , 2006, Anesthesia and analgesia.