Estimation of pulse arrival time using impedance plethysmogram from body composition scales

Long-term periodic monitoring of cardiovascular function in unobtrusive way has been a challenge in sensor research lately. This work presents the investigation of the method for pulse arrival time (PAT) estimation using body composition scales. It employs the electrocardiogram and the impedance plethysmogram (IPG) which are recorded from palm and plantar electrodes already integrated into body composition scales. Four subjects were involved in the experiment. The IPG was acquired from a single-foot and foot-to-foot and compared to the reference method - photoplethysmography. The range of correlation coefficient obtained in different methods varied from 0.7 to 0.94 showing that small PAT variations can be tracked using the IPG signals. Such results suggest that body composition scales could be supplemented with additional parameter for the assessment of arterial stiffness. This function will make them truly multi-parametric device for periodic health monitoring at home.

[1]  Omer T. Inan,et al.  A combined heartbeat detector based on individual BCG and IPG heartbeat detectors , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  Gregory T. A. Kovacs,et al.  Noninvasive Measurement of Physiological Signals on a Modified Home Bathroom Scale , 2012, IEEE Transactions on Biomedical Engineering.

[3]  V. C. Roberts,et al.  Blood flow in the diabetic neuropathic foot , 2004, Diabetologia.

[4]  Ramon Pallàs-Areny,et al.  Pulse arrival time estimation from the impedance plethysmogram obtained with a handheld device , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  Tetsuo Shoji,et al.  Pulse wave velocity in lower-limb arteries among diabetic patients with peripheral arterial disease. , 2003, Journal of atherosclerosis and thrombosis.

[6]  R. Pallàs-Areny,et al.  Heart rate detection from single-foot plantar bioimpedance measurements in a weighing scale , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[7]  Robert Plonsey,et al.  Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields , 1995 .

[8]  A. Murray,et al.  Relation between heart rate and pulse transit time during paced respiration , 2001, Physiological measurement.

[9]  Ramon Pallàs-Areny,et al.  Multi-signal bathroom scale to assess long-term trends in cardiovascular parameters , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  H. Struijker‐Boudier,et al.  Expert consensus document on arterial stiffness: methodological issues and clinical applications. , 2006, European heart journal.