In situ magnetic compensation for potassium spin-exchange relaxation-free magnetometer considering probe beam pumping effect.

A novel method to compensate the residual magnetic field for an atomic magnetometer consisting of two perpendicular beams of polarizations was demonstrated in this paper. The method can realize magnetic compensation in the case where the pumping rate of the probe beam cannot be ignored. In the experiment, the probe beam is always linearly polarized, whereas, the probe beam contains a residual circular component due to the imperfection of the polarizer, which leads to the pumping effect of the probe beam. A simulation of the probe beam's optical rotation and pumping rate was demonstrated. At the optimized points, the wavelength of the probe beam was optimized to achieve the largest optical rotation. Although, there is a small circular component in the linearly polarized probe beam, the pumping rate of the probe beam was non-negligible at the optimized wavelength which if ignored would lead to inaccuracies in the magnetic field compensation. Therefore, the dynamic equation of spin evolution was solved by considering the pumping effect of the probe beam. Based on the quasi-static solution, a novel magnetic compensation method was proposed, which contains two main steps: (1) the non-pumping compensation and (2) the sequence compensation with a very specific sequence. After these two main steps, a three-axis in situ magnetic compensation was achieved. The compensation method was suitable to design closed-loop spin-exchange relaxation-free magnetometer. By a combination of the magnetic compensation and the optimization, the magnetic field sensitivity was approximately 4 fT/Hz(1/2), which was mainly dominated by the noise of the magnetic shield.

[1]  L. Trahms,et al.  Magnetoencephalography with a chip-scale atomic magnetometer , 2012, Biomedical optics express.

[2]  M. Romalis,et al.  High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation. , 2002, Physical review letters.

[3]  R. Wakai,et al.  Parametric modulation of an atomic magnetometer. , 2006, Applied physics letters.

[4]  T. W. Kornack,et al.  A subfemtotesla multichannel atomic magnetometer , 2003, Nature.

[5]  D. Budker,et al.  Optical magnetometry - eScholarship , 2006, physics/0611246.

[6]  A. C. Maloof,et al.  Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer , 2009, 0910.2206.

[7]  M. Romalis,et al.  Hybrid optical pumping of optically dense alkali-metal vapor without quenching gas. , 2010, Physical review letters.

[8]  Dietmar Drung,et al.  High-performance DC SQUID read-out electronics , 2002 .

[9]  Igor Savukov,et al.  Effects of spin-exchange collisions in a high-density alkali-metal vapor in low magnetic fields , 2005 .

[10]  S. K. Lee,et al.  Calculation of magnetic field noise from high-permeability magnetic shields and conducting objects with simple geometry , 2007, 0709.2543.

[11]  Light-shift measurement and suppression in atomic spin gyroscope. , 2012, Applied optics.

[12]  Robert Wyllie,et al.  Optical magnetometer array for fetal magnetocardiography. , 2012, Optics letters.

[13]  Keigo Kamada,et al.  Sensitivity Improvement of Spin-Exchange Relaxation Free Atomic Magnetometers by Hybrid Optical Pumping of Potassium and Rubidium , 2011, IEEE Transactions on Magnetics.

[14]  Michael V. Romalis,et al.  Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer , 2004 .

[15]  Thomas G. Walker,et al.  Diffusive suppression of AC-Stark shifts in atomic magnetometers. , 2012, Optics letters.

[16]  T. W. Kornack,et al.  A low-noise ferrite magnetic shield , 2007 .

[17]  Jiancheng Fang,et al.  In situ triaxial magnetic field compensation for the spin-exchange-relaxation-free atomic magnetometer. , 2012, The Review of scientific instruments.

[18]  D. Hoffman,et al.  Magnetoencephalography with an atomic magnetometer , 2006 .