Respiratory motion‐compensated radial dynamic contrast‐enhanced (DCE)‐MRI of chest and abdominal lesions

Dynamic contrast‐enhanced (DCE)‐MRI is becoming an increasingly important tool for evaluating tumor vascularity and assessing the effectiveness of emerging antiangiogenic and antivascular agents. In chest and abdominal regions, however, respiratory motion can seriously degrade the achievable image quality in DCE‐MRI studies. The purpose of this work is to develop a respiratory motion‐compensated DCE‐MRI technique that combines the self‐gating properties of radial imaging with the reconstruction flexibility afforded by the golden‐angle view‐order strategy. Following radial data acquisition, the signal at k‐space center is first used to determine the respiratory cycle, and consecutive views during the expiratory phase of each respiratory period (34–55 views, depending on the breathing rate) are grouped into individual segments. Residual intrasegment translation of lesion is subsequently compensated for by an autofocusing technique that optimizes image entropy, while intersegment translation (among different respiratory cycles) is corrected using 3D image correlation. The resulting motion‐compensated, undersampled dynamic image series is then processed to reduce image streaking and to enhance the signal‐to‐noise ratio (SNR) prior to perfusion analysis, using either the k‐space‐weighted image contrast (KWIC) radial filtering technique or principal component analysis (PCA). The proposed data acquisition scheme also allows for high frame‐rate arterial input function (AIF) sampling and free‐breathing baseline T1 mapping. The performance of the proposed radial DCE‐MRI technique is evaluated in subjects with lung and liver lesions, and results demonstrate that excellent pixelwise perfusion maps can be obtained with the proposed methodology. Magn Reson Med 60:1135–1146, 2008. © 2008 Wiley‐Liss, Inc.

[1]  V Rasche,et al.  MR fluoroscopy using projection reconstruction multi‐gradient‐echo (prMGE) MRI , 1999, Magnetic resonance in medicine.

[2]  A. G. Collins,et al.  Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artefacts in MR imaging. , 1985, Journal of computer assisted tomography.

[3]  A. Jackson,et al.  Comparative study into the robustness of compartmental modeling and model‐free analysis in DCE‐MRI studies , 2006, Journal of magnetic resonance imaging : JMRI.

[4]  J Velikina,et al.  Highly constrained backprojection for time‐resolved MRI , 2006, Magnetic resonance in medicine.

[5]  M. McConnell,et al.  Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. , 1997, AJR. American journal of roentgenology.

[6]  Olaf Dössel,et al.  An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRI , 2007, IEEE Transactions on Medical Imaging.

[7]  V M Runge,et al.  Respiratory gating in magnetic resonance imaging at 0.5 Tesla. , 1984, Radiology.

[8]  G. A. Ladinsky,et al.  Image metric‐based correction (autofocusing) of motion artifacts in high‐resolution trabecular bone imaging , 2007, Journal of magnetic resonance imaging : JMRI.

[9]  Andrew C Larson,et al.  Self‐gated cardiac cine MRI , 2004, Magnetic resonance in medicine.

[10]  P. Batchelor,et al.  Matrix description of general motion correction applied to multishot images , 2005, Magnetic resonance in medicine.

[11]  Ganesh Adluru,et al.  Model‐based registration for dynamic cardiac perfusion MRI , 2006, Journal of magnetic resonance imaging : JMRI.

[12]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.

[13]  David Atkinson,et al.  Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion , 1997, IEEE Transactions on Medical Imaging.

[14]  S J Riederer,et al.  Autocorrection of three-dimensional time-of-flight MR angiography of the Circle of Willis. , 2001, AJR. American journal of roentgenology.

[15]  Oded Gonen,et al.  Optimizing the precision‐per‐unit‐time of quantitative MR metrics: Examples for T1, T2, and DTI , 2007, Magnetic resonance in medicine.

[16]  Weijing Sun,et al.  Phase I trial of the antivascular agent combretastatin A4 phosphate on a 5-day schedule to patients with cancer: magnetic resonance imaging evidence for altered tumor blood flow. , 2003, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[17]  Tristan Barrett,et al.  MRI of tumor angiogenesis , 2007, Journal of magnetic resonance imaging : JMRI.

[18]  K. T. Block,et al.  Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint , 2007, Magnetic resonance in medicine.

[19]  A. Padhani,et al.  Effects of platinum/taxane based chemotherapy on acute perfusion in human pelvic tumours measured by dynamic MRI , 2005, British Journal of Cancer.

[20]  D. Peters,et al.  Undersampled projection reconstruction applied to MR angiography , 2000, Magnetic resonance in medicine.

[21]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .

[22]  V Rasche,et al.  Motion compensated projection reconstruction , 1999, Magnetic resonance in medicine.

[23]  B. Rutt,et al.  Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state , 2003, Magnetic resonance in medicine.

[24]  P. Tofts,et al.  Measurement of the blood‐brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts , 1991, Magnetic resonance in medicine.

[25]  Peter Boesiger,et al.  Lattice permutation for reducing motion artifacts in radial and spiral dynamic imaging , 2006, Magnetic resonance in medicine.

[26]  Andrew C Larson,et al.  Preliminary investigation of respiratory self‐gating for free‐breathing segmented cine MRI , 2005, Magnetic resonance in medicine.

[27]  H K Song,et al.  k‐Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI , 2000, Magnetic resonance in medicine.

[28]  Volker Rasche,et al.  Continuous radial data acquisition for dynamic MRI , 1995, Magnetic resonance in medicine.

[29]  Lawrence Dougherty,et al.  Dynamic MRI with projection reconstruction and KWIC processing for simultaneous high spatial and temporal resolution , 2004, Magnetic resonance in medicine.

[30]  T W Redpath,et al.  Accuracy of T1 measurement in dynamic contrast‐enhanced breast MRI using two‐ and three‐dimensional variable flip angle fast low‐angle shot , 1999, Journal of magnetic resonance imaging : JMRI.

[31]  John F. Nunn,et al.  Respiratory Physiology—the essentials , 1975 .

[32]  M. Knopp,et al.  Dynamic contrast‐enhanced MRI using Gd‐DTPA: Interindividual variability of the arterial input function and consequences for the assessment of kinetics in tumors , 2001, Magnetic resonance in medicine.

[33]  A Heerschap,et al.  Method for quantitative mapping of dynamic MRI contrast agent uptake in human tumors , 2001, Journal of magnetic resonance imaging : JMRI.

[34]  S J Riederer,et al.  Image metric‐based correction (Autocorrection) of motion effects: Analysis of image metrics , 2000, Journal of magnetic resonance imaging : JMRI.

[35]  A. Padhani Dynamic contrast‐enhanced MRI in clinical oncology: Current status and future directions , 2002, Journal of magnetic resonance imaging : JMRI.

[36]  William H. Press,et al.  Numerical recipes in C , 2002 .

[37]  R C Grimm,et al.  Respiratory kinematics of the upper abdominal organs: A quantitative study , 1992, Magnetic resonance in medicine.

[38]  J. D. O'Sullivan,et al.  A Fast Sinc Function Gridding Algorithm for Fourier Inversion in Computer Tomography , 1985, IEEE Transactions on Medical Imaging.

[39]  D C Noll,et al.  Consistent projection reconstruction (CPR) techniques for MRI , 1993, Magnetic resonance in medicine.

[40]  B K Rutt,et al.  Temporal sampling requirements for the tracer kinetics modeling of breast disease. , 1998, Magnetic resonance imaging.