Electrochemical Techniques for the Modification of Microelectrodes

The deposition of enzymes using electrochemically aided adsorption in the presence of glutaraldehyde allows spatially well controlled protein layers to be formed. By adjusting the deposition parameters (i.e. current, pulse, duration and amplitude) this technique, originally developed for the deposition of glucose oxidase (GOx), can be readily applied to several other enzymes. As an example, and illustrating the potential of this technique in the fabrication of multisensors, a glucose-sarcosine dual analyte sensor is described. | The deposition of enzymes using electrochemically aided adsorption in the presence of glutaraldehyde allows spatially well controlled protein layers to be formed. By adjusting the deposition parameters (i.e. current, pulse, duration and amplitude) this technique, originally developed for the deposition of glucose oxidase (GOx), can be readily applied to several other enzymes. As an example, and illustrating the potential of this technique in the fabrication of multisensors, a glucose-sarcosine dual analyte sensor is described.

[1]  Ursula Bilitewski,et al.  Mass Production of Biosensors , 1993 .

[2]  Isao Karube,et al.  A Micro Planar Ampehometric Glucose Sensor Using an Isfet as a Reference Electrode , 1986 .

[3]  Christopher R. Lowe,et al.  Multi-analyte microelectronic biosensors , 1990 .

[4]  N. F. Rooij,et al.  Fabrication and characterization of a planar electrochemical cell and its application as a glucose sensor , 1989 .

[5]  K. W. Johnson Reproducible electrodeposition of biomolecules for the fabrication of miniature electroenzymatic biosensors , 1991 .

[6]  W. Schuhmann,et al.  Polypyrrole, a new possibility for covalent binding of oxidoreductases to electrode surfaces as a base for stable biosensors , 1990 .

[7]  Philip N. Bartlett,et al.  Electrochemical immobilisation of enzymes: Part II. Glucose oxidase immobilised in poly-N-methylpyrrole , 1987 .

[8]  Christopher R. Lowe,et al.  Enzyme entrapment in electrically conducting polymers. Immobilisation of glucose oxidase in polypyrrole and its application in amperometric glucose sensors , 1986 .

[9]  K. Wagatsuma,et al.  Analysis of binary alloy surfaces by low wattage glow discharge emission spectrometry , 1984 .

[10]  C. Lowe,et al.  Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers. , 1988, Analytical chemistry.

[11]  Hans Sigrist,et al.  Light–Dependent, Covalent Immobilization of Biomolecules on ‘Inert’ Surfaces , 1992, Bio/Technology.

[12]  T. Moriizumi,et al.  Solid state biosensors using thin-film electrodes , 1987 .

[13]  Alexander M. Yacynych,et al.  Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors , 1990 .

[14]  S. Yamauchi,et al.  Electrochemical Fabrication of Amperometric Microenzyme Sensor , 1989 .

[15]  C. Malitesta,et al.  Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film. , 1990, Analytical chemistry.

[16]  Hiroshi Yoneyama,et al.  Glucose sensitivity of polypyrrole films containing immobilized glucose oxidase and hydroquinonesulfonate ions , 1991 .

[17]  Joseph Wang,et al.  Miniaturized glucose sensors based on electrochemical codeposition of rhodium and glucose oxidase onto carbon-fiber electrodes , 1992 .

[18]  H. Müller,et al.  Amperometric glucose sensor with a photolithographically patterned enzyme membrane , 1991 .

[19]  Antonio Guerrieri,et al.  Interference-free glucose sensor based on glucose-oxidase immobilized in an overoxidized non-conducting polypyrrole film , 1992 .

[20]  Joseph Wang,et al.  Enzyme nanoband electrodes , 1993 .

[21]  M. Koudelka-Hep,et al.  Electrodeposition of glucose oxidase for the fabrication of miniature sensors , 1993 .

[22]  Christopher R. Lowe,et al.  Covalent electropolymerization of glucose oxidase in polypyrrole , 1992 .