Image distortion and its correction in linear galvanometric mirrors–based laser-scanning microscopy

Abstract. To simplify imaging focusing and calibration tasks, a laser-scanning microscope needs to scan at a moderate frame rate. The inertia of a galvanometric scanner leads to time delays when following external commands, which subsequently introduces image distortions that deteriorate as scan frequency increases. Sinusoidal and triangular waveforms were examined as fast axis driving patterns. The interplay among driving pattern, frequency, sampling rate, phase shift, linear scanning range, and their effect on reconstructed images was discussed. Utilizing position feedback from the linear galvo scanners, the effect of response time could be automatically compensated in real time. Precompensated triangular driving waveform offered the least amount of image distortion.

[1]  J. Pawley,et al.  Handbook of Biological Confocal Microscopy , 1990, Springer US.

[2]  Redmond P. Aylward,et al.  Advanced galvanometer‐based optical scanner design , 2003 .

[3]  R. Webb,et al.  In vivo confocal scanning laser microscopy of human skin: melanin provides strong contrast. , 1995, The Journal of investigative dermatology.

[4]  Haishan Zeng,et al.  In vivo video rate multiphoton microscopy imaging of human skin. , 2011, Optics letters.

[5]  Ian Parker,et al.  Video-rate confocal microscopy. , 2003, Methods in enzymology.

[6]  I. Parker,et al.  Construction of a two-photon microscope for video-rate Ca(2+) imaging. , 2001, Cell calcium.

[7]  S. Paddock Principles and practices of laser scanning confocal microscopy , 2000, Molecular biotechnology.

[8]  I. Parker,et al.  Construction of a confocal microscope for real-time x-y and x-z imaging. , 1999, Cell calcium.

[9]  W B Amos,et al.  How the Confocal Laser Scanning Microscope entered Biological Research , 2003, Biology of the cell.

[10]  Yiming Li,et al.  Author's Personal Copy Biomedical Signal Processing and Control Software Controlling Algorithms for the System Performance Optimization of Confocal Laser Scanning Microscope , 2022 .

[11]  Martin Oheim,et al.  Principles of two-photon excitation fluorescence microscopy and other nonlinear imaging approaches. , 2006, Advanced drug delivery reviews.

[12]  Karel Svoboda,et al.  ScanImage: Flexible software for operating laser scanning microscopes , 2003, Biomedical engineering online.

[13]  Michael J. Sanderson,et al.  Acquisition of Multiple Real-Time Images for Laser Scanning Microscopy , 2004 .