Effects of Skin Pigmentation on Pulse Oximeter Accuracy at Low Saturation

Background: It is uncertain whether skin pigmentation affects pulse oximeter accuracy at low HbO2 saturation. Methods: The accuracy of finger pulse oximeters during stable, plateau levels of arterial oxygen saturation (Sao2) between 60 and 100% were evaluated in 11 subjects with darkly pigmented skin and in 10 with light skin pigmentation. Oximeters tested were the Nellcor N-595 with the OxiMax-A probe (Nellcor Inc., Pleasanton, CA), the Novametrix 513 (Novametrix Inc., Wallingford, CT), and the Nonin Onyx (Nonin Inc., Plymouth, MN). Semisupine subjects breathed air-nitrogen-carbon dioxide mixtures through a mouthpiece. A computer used end-tidal oxygen and carbon dioxide concentrations determined by mass spectrometry to estimate breath-by-breath Sao2, from which an operator adjusted inspired gas to rapidly achieve 2- to 3-min stable plateaus of desaturation. Comparisons of oxygen saturation measured by pulse oximetry (Spo2) with Sao2 (by Radiometer OSM3) were used in a multivariate model to determine the interrelation between saturation, skin pigmentation, and oximeter bias (Spo2 − Sao2). Results: At 60–70% Sao2, Spo2 (mean of three oximeters) overestimated Sao2 (bias ± SD) by 3.56 ± 2.45% (n = 29) in darkly pigmented subjects, compared with 0.37 ± 3.20% (n = 58) in lightly pigmented subjects (P < 0.0001). The SD of bias was not greater with dark than light skin. The dark-light skin differences at 60–70% Sao2 were 2.35% (Nonin), 3.38% (Novametrix), and 4.30% (Nellcor). Skin pigment-related differences were significant with Nonin below 70% Sao2, with Novametrix below 90%, and with Nellcor at all ranges. Pigment-related bias increased approximately in proportion to desaturation. Conclusions: The three tested pulse oximeters overestimated arterial oxygen saturation during hypoxia in dark-skinned individuals.

[1]  K. Strohl,et al.  Agreement between noninvasive oximetric values for oxygen saturation. , 1990, Chest.

[2]  M. F. Battito The effect of fingerprinting ink on pulse oximetry. , 1989, Anesthesia and analgesia.

[3]  R. From,et al.  Laryngeal trauma during awake fiberoptic intubation. , 2002, Anesthesia and analgesia.

[4]  W B Runciman,et al.  Potential errors in pulse oximetry III: Effects of interference, dyes, dyshaemoglobins and other pigments * , 1991, Anaesthesia.

[5]  C. Camargo,et al.  Effect of skin pigmentation on pulse oximetry accuracy in the emergency department. , 1998, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[6]  A. Ries,et al.  Skin color and ear oximetry. , 1989, Chest.

[7]  H. Mcnamara,et al.  The effect of meconium on neonatal and fetal reflectance pulse oximetry , 1990, Journal of perinatal medicine.

[8]  M. Kelner,et al.  Effects of intravenously administered dyes on pulse oximetry readings. , 1986, Anesthesiology.

[9]  R. Goucke Hazards of henna. , 1989, Anesthesia and analgesia.

[10]  K. P. Hui,et al.  Factors influencing pulse oximetry as compared to functional arterial saturation in multi-ethnic Singapore. , 1993, Singapore medical journal.

[11]  J. Scribante,et al.  Accuracy of pulse oximetry in pigmented patients. , 1996, South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde.

[12]  R. Zeballos,et al.  Reliability of noninvasive oximetry in black subjects during exercise and hypoxia. , 1991, The American review of respiratory disease.

[13]  J R Emery,et al.  Skin pigmentation as an influence on the accuracy of pulse oximetry. , 1987, Journal of perinatology : official journal of the California Perinatal Association.

[14]  D C Hoaglin,et al.  The Effect of Nail Polish on Pulse Oximetry , 1988, Anesthesia and analgesia.

[15]  J. Severinghaus,et al.  Recent Developments in Pulse Oximetry , 1992, Anesthesiology.

[16]  M J Tobin,et al.  Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator-dependent patients. , 1990, Chest.

[17]  D. Leasa Noninvasive blood gas monitoring: a review for use in the adult critical care unit. Technology Subcommittee of the Working Group on Critical Care, Ontario Ministry of Health. , 1992, CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne.