대형 콘크리트 판넬 구조의 수직접합부 전단내력 ( Shear Strength of Vertical Joints in Large Concrete Panel structures )
暂无分享,去创建一个
In large concrete panel structures, the design of joints which
interconnect panels, is important to decide of the load-bearing
capacity of structures. Being various factors in the design of
joints, it is difficult to develop a theoretical system for the
structural analysis of large concrete panel structures. Therefore
there is a tendency to depend on the experiment. Experimental study
was performed to investigate the strength and the mechanical behavior
of vertical joint. For this, 20 specimens were tested with following
parameters;
(1)Joint type : A, B, C, D, E
(2)Number of loop bar : 2, 3
(3)Location of loop bar : In or out place in shear key