A Reliable Statistical Method to Detect Eyeblink-Artefacts from Electroencephalogram Data Only

For data preprocessing and artefact removal in an ERP experiment we were confronted with the question how blink artefacts can be detected reliably, even in the absence of usable electrooculogram (EOG) data. We propose an objective and quantitative method for the automatic detection of eyeblink artefacts from raw data using extreme value statistics, with a p-value acting as a threshold parameter. For testing the method, we used 29 channel electroencephalogram recordings of 55 healthy subjects. A total 7,700 s of EEG were analysed. The proposed method was found to detect blink artefacts reliably, showing that extreme value statistics can be employed to detect blink artefacts, even in the absence of EOG recordings.

[1]  J. Kamiya,et al.  A simple on-line technique for removing eye movement artifacts from the EEG. , 1973, Electroencephalography and clinical neurophysiology.

[2]  G. Pfurtscheller,et al.  A fully automated correction method of EOG artifacts in EEG recordings , 2007, Clinical Neurophysiology.

[3]  C. Joyce,et al.  Automatic removal of eye movement and blink artifacts from EEG data using blind component separation. , 2004, Psychophysiology.

[4]  N. Kawabata Test of statistical stability of the electroencephalogram , 1976, Biological Cybernetics.

[5]  Terence W. Picton,et al.  Ocular artifacts in recording EEGs and event-related potentials II: Source dipoles and source components , 2005, Brain Topography.

[6]  R Core Team,et al.  R: A language and environment for statistical computing. , 2014 .

[7]  A. Schlögl,et al.  Artifact Processing in Computerized Analysis of Sleep EEG – A Review , 1999, Neuropsychobiology.

[8]  Patrick Berg,et al.  Artifact Correction of the Ongoing EEG Using Spatial Filters Based on Artifact and Brain Signal Topographies , 2002, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[9]  E Donchin,et al.  A new method for off-line removal of ocular artifact. , 1983, Electroencephalography and clinical neurophysiology.

[10]  T. Gasser,et al.  The correction of EOG artifacts by frequency dependent and frequency independent methods. , 1986, Psychophysiology.

[11]  Abbas Erfanian,et al.  A fully automatic ocular artifact suppression from EEG data using higher order statistics: improved performance by wavelet analysis. , 2010, Medical engineering & physics.

[12]  Sven Hoffmann,et al.  The Correction of Eye Blink Artefacts in the EEG: A Comparison of Two Prominent Methods , 2008, PloS one.

[13]  R. Barry,et al.  Removal of ocular artifact from the EEG: a review , 2000, Neurophysiologie Clinique/Clinical Neurophysiology.

[14]  J. Kenemans,et al.  Removal of the ocular artifact from the EEG: a comparison of time and frequency domain methods with simulated and real data. , 1991, Psychophysiology.

[15]  Ricardo Nuno Vig Extraction of' ocular artefacts from EEG using independent component analysis , 1997 .

[16]  E. Gumbel,et al.  Statistics of extremes , 1960 .

[17]  R. Elul Gaussian Behavior of the Electroencephalogram: Changes during Performance of Mental Task , 1969, Science.

[18]  John W. Eaton,et al.  GNU Octave Manual Version 3 , 2008 .

[19]  Yong Yang,et al.  Automatic Removal of Eye-Movement and Blink Artifacts from EEG Signals , 2010, Brain Topography.

[20]  S. Nadarajah,et al.  Extreme value distributions , 2013 .

[21]  Martin J. McKeown,et al.  Removing electroencephalographic artifacts: comparison between ICA and PCA , 1998, Neural Networks for Signal Processing VIII. Proceedings of the 1998 IEEE Signal Processing Society Workshop (Cat. No.98TH8378).

[22]  R. Kass,et al.  Automatic correction of ocular artifacts in the EEG: a comparison of regression-based and component-based methods. , 2004, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[23]  R. Verleger Valid identification of blink artefacts: are they larger than 50 microV in EEG records? , 1993, Electroencephalography and clinical neurophysiology.

[24]  T. Sejnowski,et al.  Removing electroencephalographic artifacts by blind source separation. , 2000, Psychophysiology.

[25]  Xavier Robin,et al.  pROC: an open-source package for R and S+ to analyze and compare ROC curves , 2011, BMC Bioinformatics.

[26]  N Ishii,et al.  On the stationarity and normality of the electroencephalographic data during sleep stages. , 1978, Computer programs in biomedicine.

[27]  Wolfgang Skrandies,et al.  Topographical Changes of ERPs Related to Human Semantic Learning , 2012 .

[28]  S. Hillyard,et al.  Eye movement artifact in the CNV. , 1970, Electroencephalography and clinical neurophysiology.

[29]  P. Berg,et al.  The residual after correcting event-related potentials for blink artifacts. , 1986, Psychophysiology.