Implantable Cardioverter-Defibrillator

Primary Prevention  Ischemic cardiomyopathy with New York Heart Association (NYHA) functional class II or III symptoms, a history of myocardial infarction at least 40 days before ICD treatment, and left ventricular ejection fraction of 35% or less; or  Ischemic cardiomyopathy with NYHA functional class I symptoms, a history of myocardial infarction at least 40 days before ICD treatment, and left ventricular ejection fraction of 30% or less; or  Nonischemic dilated cardiomyopathy and left ventricular ejection fraction of 35% or less, after reversible causes have been excluded, and the response to optimal medical therapy has been adequately determined; or  Hypertrophic cardiomyopathy (HCM) with 1 or more major risk factors for sudden cardiac death (history of premature HCM-related sudden death in ≥1 first-degree relatives younger than 50 years; left ventricular hypertrophy >30 mm; ≥1 runs of nonsustained ventricular tachycardia at heart rates of ≥120 beats per minute on 24-hour Holter monitoring; prior unexplained syncope inconsistent with neurocardiogenic origin) and judged to be at high risk for sudden cardiac death by a physician experienced in the care of patients with HCM.  Diagnosis of any one of the following cardiac ion channelopathies and considered to be at high risk for sudden cardiac death (see Policy Guidelines section): o congenital long QT syndrome; OR o Brugada syndrome; OR o short QT syndrome; OR o catecholaminergic polymorphic ventricular tachycardia.

[1]  W. Krassowska,et al.  Choosing the Optimal Monophasic and Biphasic Waveforms for Ventricular Defibrillation , 1995, Journal of cardiovascular electrophysiology.

[2]  J. Bigger,et al.  Prophylactic use of implanted cardiac defibrillators in patients at high risk for ventricular arrhythmias after coronary-artery bypass graft surgery. Coronary Artery Bypass Graft (CABG) Patch Trial Investigators. , 1997, The New England journal of medicine.

[3]  R. Fletcher,et al.  Optimization of Biphasic Waveforms for Human Nonthoracotomy Defibrillation , 1993, Circulation.

[4]  B. Lüderitz,et al.  Interactions between drugs and devices: experimental and clinical studies. , 1994, American heart journal.

[5]  K. Kuck,et al.  Primary Prevention of Sudden Cardiac Death in Idiopathic Dilated Cardiomyopathy: The Cardiomyopathy Trial (CAT) , 2002, Circulation.

[6]  W. D. de Voogt Pacemaker leads: performance and progress. , 1999, American Journal of Cardiology.

[7]  S. Sato,et al.  Effects of lidocaine and mexiletine on defibrillation energy requirements in animals treated with flecainide. , 1998, Resuscitation.

[8]  A. Tang,et al.  Class III antiarrhythmic effects of LY-190147 on defibrillation threshold. , 1996, Journal of cardiovascular pharmacology.

[9]  P. Roberts,et al.  Improved Efficacy of Anodal Biphasic Defibrillation Shocks Following a Failed Defibrillation Attempt , 1999, Pacing and clinical electrophysiology : PACE.

[10]  M. Kroll,et al.  Effects of Polarity on Defibrillation Thresholds Using a Biphasic Waveform in a Hot Can Electrode System , 1997, Pacing and clinical electrophysiology : PACE.

[11]  K Isaaz,et al.  Antibiotic prophylaxis for permanent pacemaker implantation: a meta-analysis. , 1998, Circulation.

[12]  P. S. Chen,et al.  Effect of Shock Waveform on Relationship Between Upper Limit of Vulnerability and Defibrillation Threshold , 1998, Journal of cardiovascular electrophysiology.

[13]  J. Cohen,et al.  Sutureless epicardial pacemaker lead: a satisfactory preliminary experience. , 1975, Chest.

[14]  K. Lee,et al.  A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators. , 1999, The New England journal of medicine.

[15]  M E McIvor,et al.  Environmental Electromagnetic Interference from Electronic Article Surveillance Devices: Interactions with an ICD , 1995, Pacing and clinical electrophysiology : PACE.

[16]  P. S. Chen,et al.  Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillator. , 1994, Journal of the American College of Cardiology.

[17]  M. McIvor,et al.  Study of Pacemaker and Implantable Cardioverter Defibrillator Triggering by Electronic Article Surveillance Devices (SPICED TEAS) , 1998, Pacing and clinical electrophysiology : PACE.

[18]  M Gent,et al.  Canadian implantable defibrillator study (CIDS) : a randomized trial of the implantable cardioverter defibrillator against amiodarone. , 2000, Circulation.

[19]  S. Furman,et al.  Insulation Lead Failure: Is it a Matter of Insulation Coating, Venous Approach, or Both? , 1998, Pacing and clinical electrophysiology : PACE.

[20]  George A. Johnson,et al.  Serial Defibrillation Threshold Measures in Man: A Prospective Controlled Study , 1995, Journal of cardiovascular electrophysiology.

[21]  A J Camm,et al.  Atrioverter: an implantable device for the treatment of atrial fibrillation. , 1998, Circulation.

[22]  T. Guarnieri,et al.  The Automatic Implantable Cardioverter Defibrillator: T Wave Sensing in the Newest Generation , 1988, Pacing and clinical electrophysiology : PACE.

[23]  G. Flaker,et al.  Comparison of Right– and Left–Sided Pectoral Implantation Parameters with the Jewel Active Can Cardiodefibrillator , 1998, Pacing and clinical electrophysiology : PACE.

[24]  P. Wolf,et al.  Epicardial mapping of ventricular defibrillation with monophasic and biphasic shocks in dogs. , 1993, Circulation research.

[25]  S. Saksena,et al.  Experience with a third-generation implantable cardioverter-defibrillator. , 1991, The American journal of cardiology.

[26]  Douglas S Lee,et al.  Effectiveness of implantable defibrillators for preventing arrhythmic events and death: a meta-analysis. , 2003, Journal of the American College of Cardiology.

[27]  M. Gold,et al.  Prognostic value of the signal-averaged electrocardiogram and a prolonged QRS in ischemic and nonischemic cardiomyopathy. , 1995, The American journal of cardiology.

[28]  W Greatbatch,et al.  The Lithium/Iodine Battery: A Historical Perspective , 1992, Pacing and clinical electrophysiology : PACE.

[29]  R. Winkle,et al.  Effect of duration of ventricular fibrillation on defibrillation efficacy in humans. , 1990, Circulation.

[30]  D G Gibson,et al.  Effects of abnormal activation on the time course of the left ventricular pressure pulse in dilated cardiomyopathy , 1992, British heart journal.

[31]  P E Oyer,et al.  Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator. , 1985, Circulation.

[32]  A. Henning,et al.  Radiation‐Induced Effects in Multiprogrammable Pacemakers and Implantable Defibrillators , 1991, Pacing and clinical electrophysiology : PACE.

[33]  J. Jones,et al.  Conditioning prepulse of biphasic defibrillator waveforms enhances refractoriness to fibrillation wavefronts. , 1991, Circulation research.

[34]  W. Jung,et al.  Failure of an Implantable Cardioverter‐ Defibrillator to Redetect Ventricular Fibrillation in Patients With a Nonthoracotomy Lead System , 1992, Circulation.

[35]  P. Wolf,et al.  Does reducing capacitance have potential for further miniaturisation of implantable defibrillators? , 1997, Heart.

[36]  C. Pande Thermoplastic Polyurethanes as Insulating Materials for Long‐Life Cardiac Pacing Leads , 1983, Pacing and clinical electrophysiology : PACE.

[37]  J. Sluetz,et al.  In vivo thrombogenicity of implantable cardiac pacing leads. , 1980, Biomaterials, medical devices, and artificial organs.

[38]  T J Cohen,et al.  A Theoretical Right Atrial Pressure Feedback Heart Rate Control System to Restore Physiologic Control to the Rate‐limited Heart , 1984, Pacing and clinical electrophysiology : PACE.

[39]  A. Camm,et al.  Efficacy of Automatic Multimodal Device Therapy for Ventricular Tachyarrhythmias as Delivered by a New Implantable Pacing Cardioverter‐Defibrillator: Results of a European Multicenter Study of 102 Implants , 1992, Circulation.

[40]  J. Schuder,et al.  Contour graph for relating per cent success in achieving ventricular defibrillation to duration, current, and energy content of shock. , 1979, American heart journal.

[41]  A. Tajik,et al.  Mechanism of hemodynamic improvement by dual-chamber pacing for severe left ventricular dysfunction: an acute Doppler and catheterization hemodynamic study. , 1995, Journal of the American College of Cardiology.

[42]  P D Wolf,et al.  Prolongation of repolarization time by electric field stimulation with monophasic and biphasic shocks in open-chest dogs. , 1991, Circulation research.

[43]  G. Breithardt,et al.  Optimizing Defibrillation Through Improved Waveforms , 1995, Pacing and clinical electrophysiology : PACE.

[44]  R. Winkle,et al.  Mortality in patients with implanted automatic defibrillators. , 1983, Annals of internal medicine.

[45]  A. Arnold,et al.  Prophylactic antibiotics for cardiac pacemaker implantation. A prospective trail. , 1981, British heart journal.

[46]  M. Gold,et al.  Effects of waveform and polarity on defibrillation thresholds in humans using a transvenous lead system. , 1996, The American journal of cardiology.

[47]  A. Brandes,et al.  Electrophysiological Characteristics of Bipolar Membrane Carbon Leads With and Without Steroid Elution Compared With a Conventional Carbon and a Steroid‐Fluting Platinum Lead , 1996, Pacing and clinical electrophysiology : PACE.

[48]  M. Silka,et al.  Sudden Cardiac Death and the Use ofImplantable Cardioverter‐Defibrillators in Pediatric Patients , 1993, Circulation.

[49]  J. Bourke,et al.  “Are the Differences between ‘High Performance’ Pacing Leads Clinically Significant? A Comparison of Sintered Platinum and Activated Carbon” , 1987, The International journal of artificial organs.

[50]  H. Crijns,et al.  Randomized study of implantable defibrillator as first-choice therapy versus conventional strategy in postinfarct sudden death survivors. , 1995, Circulation.

[51]  D. Gilbert,et al.  Prophylactic antibiotics and the insertion of permanent transvenous cardiac pacemakers. , 1978, The Journal of thoracic and cardiovascular surgery.

[52]  Peng-Sheng Chen,et al.  Short Biphasic Pulses from 90 Microfarad Capacitors Lower Defibrillation Threshold , 1996, Pacing and clinical electrophysiology : PACE.

[53]  W. Jung,et al.  Effects of Antiarrhythmic Drugs on Defibrillation Threshold in Patients with the Implantable Cardioverter Defibrillator , 1992, Pacing and clinical electrophysiology : PACE.

[54]  A. Garfinkel,et al.  Importance of location and timing of electrical stimuli in terminating sustained functional reentry in isolated swine ventricular tissues: evidence in support of a small reentrant circuit. , 1997, Circulation.

[55]  K. Stokes,et al.  A New Efficient NanoTip Lead , 1990, Pacing and clinical electrophysiology : PACE.

[56]  L A Geddes,et al.  Strength-duration curves for trapezoidal waveforms of various tilts for transchest defibrillation in animals. , 1978, Medical instrumentation.

[57]  H. Kay,et al.  Clinical determinants of mortality in chronic congestive heart failure secondary to idiopathic dilated or to ischemic cardiomyopathy. , 1987, The American journal of cardiology.

[58]  E. Fain,et al.  Improved internal defibrillation efficacy with a biphasic waveform. , 1989, American heart journal.

[59]  M. Niebauer,et al.  The effect of newer antiarrhythmic drugs on defibrillation threshold , 1980, Critical care medicine.

[60]  C. H. Chen,et al.  Improved left ventricular mechanics from acute VDD pacing in patients with dilated cardiomyopathy and ventricular conduction delay. , 1999, Circulation.

[61]  S. Connolly,et al.  Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials. AVID, CASH and CIDS studies. Antiarrhythmics vs Implantable Defibrillator study. Cardiac Arrest Study Hamburg . Canadian Implantable Defibrillator Study. , 2000, European heart journal.

[62]  L. Geddes,et al.  Elevation of ventricular defibrillation threshold in dogs by antiarrhythmic drugs. , 1979, American heart journal.

[63]  F. Marchlinski,et al.  Electrocardiographically Documented Unnecessary, Spontaneous Shocks in 241 Patients With Implantable Cardioverter Defibrillators , 1992, Pacing and clinical electrophysiology : PACE.

[64]  Douglas L. Jones,et al.  Correlation Between the Ventricular Electrogram Amplitude in Sinus Rhythm and in Ventricular Fibrillation , 1990, Pacing and clinical electrophysiology : PACE.

[65]  L Tung,et al.  Electroporation of Cardiac Cell Membranes with Monophasic or Biphasic Rectangular Pulses , 1991, Pacing and clinical electrophysiology : PACE.

[66]  A. M. Scher,et al.  Influence of Cardiac Fiber Orientation on Wavefront Voltage, Conduction Velocity, and Tissue Resistivity in the Dog , 1979, Circulation research.

[67]  H. Edmonds,et al.  Changes in cerebral perfusion during third-generation implantable cardioverter defibrillator testing. , 1994, American heart journal.

[68]  J. Ruskin,et al.  Subclavian Crush Syndrome Complicating Transvenous Cardioverter Defibrillator Systems , 1995, Pacing and clinical electrophysiology : PACE.

[69]  E. Gang,et al.  Upper limit of vulnerability reliably predicts the defibrillation threshold in humans. , 1994, Circulation.

[70]  E. Daoud,et al.  Biventricular pacing in patients with congestive heart failure: two prospective randomized trials. The VIGOR CHF and VENTAK CHF Investigators. , 1999, The American journal of cardiology.

[71]  N. G. Sepulveda,et al.  Finite element analysis of cardiac defibrillation current distributions , 1990, IEEE Transactions on Biomedical Engineering.

[72]  H. Calkins,et al.  Implantable cardioverter-defibrillator therapy in 300 patients with coronary artery disease presenting exclusively with ventricular fibrillation. , 1994, American heart journal.

[73]  D P Zipes,et al.  Termination of ventricular fibrillation in dogs by depolarizing a critical amount of myocardium. , 1975, The American journal of cardiology.

[74]  G. Balady,et al.  Electrocautery and pacemakers: management of the paced patient subject to electrocautery. , 1986, The Annals of thoracic surgery.

[75]  Singh Sotalol: Current Status and Expanding Indications. , 1999, Journal of cardiovascular pharmacology and therapeutics.

[76]  J. Mugica,et al.  Is Polyurethane Lead Insulation Still Controversial? , 1992, Pacing and clinical electrophysiology : PACE.

[77]  M. Gold,et al.  Effect of Shock Polarity on Biphasic Defibrillation Thresholds Using an Active Pectoral Lead System , 1998, Journal of cardiovascular electrophysiology.

[78]  J. Blanc,et al.  Evaluation of different ventricular pacing sites in patients with severe heart failure: results of an acute hemodynamic study. , 1997, Circulation.

[79]  F. Morady,et al.  Amiodarone versus implantable cardioverter-defibrillator:randomized trial in patients with nonischemic dilated cardiomyopathy and asymptomatic nonsustained ventricular tachycardia--AMIOVIRT. , 2003, Journal of the American College of Cardiology.

[80]  M. Chung,et al.  Effects of Extracorporeal Shock Wave Lithotripsy on Tiered Therapy Implantable Cardioverter Defibrillators , 1999, Pacing and clinical electrophysiology : PACE.

[81]  L. Liem,et al.  Mixed venous oxygen saturation for differentiating stable from unstable tachycardias. , 1991, American heart journal.

[82]  Stanley P. Azen,et al.  Defibrillator Versus &bgr;-Blockers for Unexplained Death in Thailand (DEBUT): A Randomized Clinical Trial , 2003, Circulation.

[83]  S. Cobbe,et al.  Implantable Cardioverter- Defibrillators , 1996, Scottish medical journal.

[84]  J. Calabrese,et al.  Patient and spouse acceptance and adaptation to implantable cardioverter defibrillators. , 1990, Cleveland Clinic journal of medicine.

[85]  L Seipel,et al.  Effect of amiodarone and sotalol on the defibrillation threshold in comparison to patients without antiarrhythmic drug treatment. , 1999, International journal of cardiology.

[86]  G P Walcott,et al.  Mechanisms of defibrillation. Critical points and the upper limit of vulnerability. , 1995, Journal of electrocardiology.

[87]  A. Auricchio,et al.  Potential benefit of biventricular pacing in patients with congestive heart failure and ventricular tachyarrhythmia. , 1999, The American journal of cardiology.

[88]  D. Lacroix,et al.  Triple Chamber Pacemaker for End‐Stage Heart Failure in a Patient with a Previously Implanted Automatic Defibrillator , 1998, Pacing and clinical electrophysiology : PACE.

[89]  R. Mehra,et al.  Finite element analysis of defibrillation fields in a human torso model for ventricular defibrillation. , 1998, Progress in biophysics and molecular biology.

[90]  T. Lüscher,et al.  The Potential for Inappropriate Ventricular Tachycardia Confirmation Using the Intracardiac Electrogram (EGM) Width Criterion , 1999, Pacing and clinical electrophysiology : PACE.

[91]  George A. Johnson,et al.  Prospective Randomized Comparison of Biphasic Waveform Tilt Using a Unipolar Defibrillation System , 1995, Pacing and clinical electrophysiology : PACE.

[92]  R. Cappato,et al.  Randomized comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from cardiac arrest : the Cardiac Arrest Study Hamburg (CASH). , 2000, Circulation.

[93]  Wojciech Zareba,et al.  Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. , 2002, The New England journal of medicine.

[94]  U. Wiegand,et al.  Electrophysiological Performance of a Bipolar Membrane‐Coated Titanium Nitride Electrode: A Randomized Comparison of Steroid and Nonsteroid Lead Designs , 1999, Pacing and clinical electrophysiology : PACE.

[95]  D. Hayes,et al.  Can transcutaneous electrical nerve stimulation be safely used in patients with permanent cardiac pacemakers? , 1988, Mayo Clinic proceedings.

[96]  T. Guarnieri,et al.  Success of chronic defibrillation and the role of antiarrhythmic drugs with the automatic implantable cardioverter/defibrillator. , 1987, The American journal of cardiology.

[97]  George A. Johnson,et al.  A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans. , 1989, Journal of the American College of Cardiology.

[98]  J. Vohra,et al.  Comparison of Lead Complications with Polyurethane Tined, Silicone Rubber Tined, and Wedge Tip Leads: Clinical Experience with 822 Ventricular Endocardial Leads , 1983, Pacing and clinical electrophysiology : PACE.

[99]  P. Dorian,et al.  Tedisamil increases coherence during ventricular fibrillation and decreases defibrillation energy requirements. , 1997, Cardiovascular research.

[100]  R. Fletcher,et al.  Increasing fibrillation duration enhances relative asymmetrical biphasic versus monophasic defibrillator waveform efficacy. , 1990, Circulation research.

[101]  A. Natale,et al.  Prospective Evaluation of New and Old Criteria to Discriminate Between Supraventricular and Ventricular Tachycardia in Implantable Defibrillators , 1998, Pacing and clinical electrophysiology : PACE.

[102]  P. Dorian,et al.  DL and D Sotalol Decrease Defibrillation Energy Requirements , 1989, Pacing and clinical electrophysiology : PACE.

[103]  J. Bourke,et al.  Do Electrode and Lead Design Differences for Permanent Cardiac Pacing Translate into Clinically Demonstrable Differences? (Comparison of Sintered Platinum and Activated Vitreous and Porous Carbon Electrodes) , 1989, Pacing and clinical electrophysiology : PACE.

[104]  David Longworth,et al.  Diagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac Devices , 2000, Annals of Internal Medicine.

[105]  A. Moss,et al.  Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. , 1996, The New England journal of medicine.

[106]  L. Geddes,et al.  Energy dosage for human trans-chest electrical ventricular defibrillation. , 1974, The New England journal of medicine.

[107]  R. Winkle,et al.  Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveform. , 1989, American heart journal.

[108]  S. Furman,et al.  Long‐Term Follow‐Up of Pacemaker Lead Systems: Establishment of Standards of Quality , 1995, Pacing and clinical electrophysiology : PACE.

[109]  A. M. Scher,et al.  Effect of Tissue Anisotropy on Extracellular Potential Fields in Canine Myocardium in Situ , 1982, Circulation research.

[110]  P. Karpawich,et al.  A New Low Threshold Platinized Epicardial Pacing Electrode: Comparative Evaluation in Immature Canines , 1988, Pacing and clinical electrophysiology : PACE.

[111]  L. Liem,et al.  A hemodynamically responsive antitachycardia system. Development and basis for design in humans. , 1990, Circulation.

[112]  D. Andresen,et al.  First- or second-degree atrioventricular block as a risk factor in idiopathic dilated cardiomyopathy. , 1993, The American journal of cardiology.

[113]  D L Hayes,et al.  Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial. , 1999, Journal of the American College of Cardiology.

[114]  Jens Jung,et al.  The atrial defibrillator: a stand-alone device or part of a combined dual-chamber system? , 1999, The American journal of cardiology.

[115]  J. Brugada,et al.  Enhanced Detection Criteria in Implantable Defibrillators , 1998, Journal of cardiovascular electrophysiology.

[116]  P D Wolf,et al.  Activation during ventricular defibrillation in open-chest dogs. Evidence of complete cessation and regeneration of ventricular fibrillation after unsuccessful shocks. , 1986, The Journal of clinical investigation.

[117]  M. Chauvin,et al.  Interaction Between Permanent Cardiac Pacing and Electrocautery: The Significance of Electrode Position , 1992, Pacing and clinical electrophysiology : PACE.

[118]  S. Walker,et al.  Initial experience in the extraction of chronically implanted pacemaker leads using the Excimer laser sheath , 1999, Heart.

[119]  A. Lazarus,et al.  Multisite Pacing for End‐Stage Heart Failure: Early Experience , 1996, Pacing and clinical electrophysiology : PACE.

[120]  S. Huang,et al.  Effects of long-term amiodarone therapy on the defibrillation threshold and the rate of shocks of the implantable cardioverter-defibrillator. , 1991, American heart journal.

[121]  J. Brinker,et al.  A Comparison of Platinized Grooved Electrode Performance with Ring‐Tip Electrodes , 1989, Pacing and clinical electrophysiology : PACE.

[122]  M. Omata,et al.  Shock‐Induced Refractory Period Extension and Pharmacologic Modulation of Defibrillation Threshold , 1994, Journal of cardiovascular pharmacology.

[123]  M. Gabel,et al.  Differential effects of lidocaine on defibrillation threshold with monophasic versus biphasic shock waveforms. , 1996, Circulation.

[124]  T. Cohen,et al.  Hemodynamic Responses to Rapid Pacing: A Model for Tachycardia Differentiation , 1988, Pacing and clinical electrophysiology : PACE.

[125]  M. Spach,et al.  The nature of electrical propagation in cardiac muscle. , 1983, The American journal of physiology.

[126]  R. Wesley,et al.  Ibutilide: enhanced defibrillation via plateau sodium current activation. , 1993, The American journal of physiology.