Body composition by X-ray absorptiometry and bioelectrical impedance in chronic respiratory insufficiency patients.

Nutrition assessment is important during chronic respiratory insufficiency to evaluate the level of malnutrition or obesity and should include body composition measurements. The appreciation of fat-free and fat reserves in patients with chronic respiratory insufficiency can aid in designing an adapted nutritional support, e.g., nutritional support in malnutrition and food restriction in obesity. The purpose of the present study was to cross-validate fat-free and fat mass obtained by various bioelectric impedance (BIA) formulas with the fat-free and fat mass measured by dual-energy X-ray absorptiometry (DXA) and determine the formulas that are best suited to predict the fat-free and fat mass for a group of patients with severe chronic respiratory insufficiency. Seventy-five patients (15 women and 60 men) with chronic obstructive and restrictive respiratory insufficiency aged 45-86 y were included in this study. Body composition was calculated according to 13 different BIA formulas for women and 12 for men and compared with DXA. Because of the variability, calculated as 2 standard deviations, of +/- 5.0 kg fat-free mass for women and +/- 6.4 kg for men for the best predictive formula, the use of the various existing BIA formulas was considered not clinically relevant. Therefore disease-specific formulas for patients with chronic respiratory insufficiency should be developed to improve the prediction of fat-free and fat mass by BIA in these patients.

[1]  H C Lukaski,et al.  Validation of tetrapolar bioelectrical impedance method to assess human body composition. , 1986, Journal of applied physiology.

[2]  M. Lean,et al.  Resting energy expenditure and nutritional state of patients with increased oxygen cost of breathing due to emphysema, scoliosis and thoracoplasty. , 1994, Thorax.

[3]  V. Heyward,et al.  Predictive accuracy of bioelectrical impedance in estimating body composition of Native American women. , 1994, The American journal of clinical nutrition.

[4]  B. Heitmann,et al.  Prediction of body water and fat in adult Danes from measurement of electrical impedance. A validation study. , 1990, International journal of obesity.

[5]  P. Tothill,et al.  Precision and accuracy of measurements of whole-body bone mineral: comparisons between Hologic, Lunar and Norland dual-energy X-ray absorptiometers. , 1994, The British journal of radiology.

[6]  N. Reo,et al.  Body composition in white adults by dual-energy x-ray absorptiometry, densitometry, and total body water. , 1994, The American journal of clinical nutrition.

[7]  P. Deurenberg,et al.  Assessment of body composition by bioelectrical impedance in a population aged greater than 60 y. , 1990, The American journal of clinical nutrition.

[8]  H C Lukaski,et al.  Assessment of fat-free mass using bioelectrical impedance measurements of the human body. , 1985, The American journal of clinical nutrition.

[9]  D. F. Rochester,et al.  Respiratory muscle strength and maximal voluntary ventilation in undernourished patients. , 2015, The American review of respiratory disease.

[10]  K R Westerterp,et al.  Validation of bioelectrical-impedance measurements as a method to estimate body-water compartments. , 1994, The American journal of clinical nutrition.

[11]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[12]  P. Sparling,et al.  Comparison of body composition and bone mineral measurements from two DXA instruments in young men. , 1996, The American journal of clinical nutrition.

[13]  T. Lohman,et al.  Comparison of different bioelectrical impedance analyzers in the prediction of body composition , 1989, American journal of human biology : the official journal of the Human Biology Council.

[14]  G. Hill Jonathan E. Rhoads Lecture. Body composition research: implications for the practice of clinical nutrition. , 1992, JPEN. Journal of parenteral and enteral nutrition.

[15]  D. Schoeller,et al.  Estimation of total body water by bioelectrical impedance analysis. , 1986, The American journal of clinical nutrition.

[16]  F. Della Corte,et al.  Do brainstem auditory evoked potentials detect the actual cessation of cerebral functions in brain dead patients? , 1990, Critical care medicine.

[17]  P. Tothill,et al.  Comparisons between Hologic, Lunar and Norland dual-energy X-ray absorptiometers and other techniques used for whole-body soft tissue measurements. , 1994, European journal of clinical nutrition.

[18]  P. Deurenberg,et al.  Factors affecting bioelectrical impedance measurements in humans. , 1988, European journal of clinical nutrition.

[19]  H C Lukaski,et al.  Methods for the assessment of human body composition: traditional and new. , 1987, The American journal of clinical nutrition.

[20]  T. Cole,et al.  Inter-observer variability in the measurement of body composition. , 1991, European journal of clinical nutrition.

[21]  E. Wouters,et al.  Within-day variation of bioelectrical resistance measurements in patients with chronic obstructive pulmonary disease. , 1990, Clinical nutrition.

[22]  P. Deurenberg,et al.  Body composition changes assessed by bioelectrical impedance measurements. , 1989, The American journal of clinical nutrition.

[23]  W. Kohrt,et al.  Age-related differences in body composition by hydrodensitometry and dual-energy X-ray absorptiometry. , 1993, Journal of applied physiology.

[24]  H. Lukaski,et al.  Theory and validation of the tetrapolar bioelectrical impedance method to assess human body composition , 1987 .

[25]  K. Westerterp,et al.  Body composition by bioelectrical-impedance analysis compared with deuterium dilution and skinfold anthropometry in patients with chronic obstructive pulmonary disease. , 1991, The American journal of clinical nutrition.

[26]  C. Christiansen,et al.  Validation of body composition by dual energy X-ray absorptiometry (DEXA). , 1991, Clinical physiology.

[27]  J. Wark,et al.  Evaluation of dual energy X-ray absorptiometry as a method of measurement of body fat. , 1993, European journal of clinical nutrition.

[28]  R. Rizzoli,et al.  Assessment of whole-body composition with dual-energy x-ray absorptiometry. , 1992, Radiology.

[29]  C. Christiansen,et al.  Measurement of body fat in elderly subjects by dual-energy x-ray absorptiometry, bioelectrical impedance, and anthropometry. , 1991, The American journal of clinical nutrition.

[30]  M. Van Loan,et al.  Bioelectrical impedance analysis: is it a reliable estimator of lean body mass and total body water. , 1987, Human biology.

[31]  P. Deurenberg,et al.  Body impedance is largely dependent on the intra- and extra-cellular water distribution. , 1989, European journal of clinical nutrition.

[32]  J Webber,et al.  A comparison of skinfold thickness, body mass index, bioelectrical impedance analysis and dual-energy X-ray absorptiometry in assessing body composition in obese subjects before and after weight loss. , 1994, Clinical nutrition.

[33]  J A Hodgdon,et al.  Lean body mass estimation by bioelectrical impedance analysis: a four-site cross-validation study. , 1988, The American journal of clinical nutrition.

[34]  J. Aloia,et al.  Comparative study of body composition by dual-energy x-ray absorptiometry. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[35]  P. Deurenberg,et al.  Sex and age specific prediction formulas for estimating body composition from bioelectrical impedance: a cross-validation study. , 1991, International journal of obesity.

[36]  S. Going,et al.  Detection of small changes in body composition by dual-energy x-ray absorptiometry. , 1993, The American journal of clinical nutrition.

[37]  A. Hinnebusch,et al.  In Vivo Body Composition Studies , 1990, Basic Life Sciences.

[38]  S Heshka,et al.  Dual-photon absorptiometry: comparison of bone mineral and soft tissue mass measurements in vivo with established methods. , 1989, The American journal of clinical nutrition.

[39]  G. Bray,et al.  Effect of obesity on bioelectrical impedance. , 1989, The American journal of clinical nutrition.

[40]  M. Elia Body composition analysis: an evaluation of 2 component models, multicomponent models and bedside techniques. , 1992, Clinical nutrition.

[41]  M. Van Loan,et al.  Body composition assessment: dual-energy X-ray absorptiometry (DEXA) compared to reference methods. , 1992, European journal of clinical nutrition.