Tantalum—A bioactive metal for implants

Metallic biomaterials currently in use for load-bearing orthopedic applications are mostly bioinert and therefore lack sufficient osseointegration. Although bioactive ceramics such as hydroxyapatite (HA) can spontaneously bond to living bone tissue, low fracture toughness of HA limits their use as a bone substitute for load-bearing applications. Surface modification techniques such as HA coating on metals are current options to improve osseointegration in load-bearing metal implants. Over the last few decades researchers have attempted to find a bioactive metal with high mechanical strength and excellent fatigue resistance that can bond chemically with surrounding bone for orthopedic applications. Recent in vitro, in vivo, and clinical studies demonstrated that tantalum is a promising metal that is bioactive. However, tantalum applications in biomedical devices have been limited by processing challenges rather than biological performances. In this article, we provide an overview of processing aspects and biological properties of tantalum for load-bearing orthopedic applications.

[1]  Amit Bandyopadhyay,et al.  Application of Laser Engineered Net Shaping (LENS) to manufacture porous and functionally graded structures for load bearing implants , 2009, Journal of materials science. Materials in medicine.

[2]  Amit Bandyopadhyay,et al.  Laser processing of bioactive tricalcium phosphate coating on titanium for load-bearing implants. , 2008, Acta biomaterialia.

[3]  R. Barrack,et al.  Quantitative analysis of tissue growth into human porous total hip components. , 1988, The Journal of arthroplasty.

[4]  B Vamsi Krishna,et al.  Fabrication of porous NiTi shape memory alloy structures using laser engineered net shaping. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[5]  K. Khor,et al.  Addressing processing problems associated with plasma spraying of hydroxyapatite coatings. , 1996, Biomaterials.

[6]  H. Skinner,et al.  Current concepts in orthopaedic biomaterials and implant fixation. , 1993, Instructional course lectures.

[7]  Michael Tanzer,et al.  Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. , 1999, The Journal of bone and joint surgery. British volume.

[8]  A. Bandyopadhyay,et al.  Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants. , 2010, Acta biomaterialia.

[9]  D. Howie,et al.  The proliferation and phenotypic expression of human osteoblasts on tantalum metal. , 2004, Biomaterials.

[10]  B Vamsi Krishna,et al.  Processing and biocompatibility evaluation of laser processed porous titanium. , 2007, Acta biomaterialia.

[11]  B. Vamsi Krishna,et al.  Laser Processing of Net-Shape NiTi Shape Memory Alloy , 2007 .

[12]  Vamsi Krishna Balla,et al.  Fabrication of compositionally and structurally graded Ti-TiO2 structures using laser engineered net shaping (LENS). , 2009, Acta biomaterialia.

[13]  J. Ong,et al.  Calcium phosphate coatings for medical and dental implants , 1993 .

[14]  Amit Bandyopadhyay,et al.  Engineered porous metals for implants , 2008 .

[15]  A. Bandyopadhyay,et al.  Laser-assisted Zr/ZrO(2) coating on Ti for load-bearing implants. , 2009, Acta biomaterialia.

[16]  A. Yokoyama,et al.  Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. , 2001, Biomaterials.

[17]  B Vamsi Krishna,et al.  Low stiffness porous Ti structures for load-bearing implants. , 2007, Acta biomaterialia.

[18]  Vamsi Krishna Balla,et al.  Direct laser processing of a tantalum coating on titanium for bone replacement structures. , 2010, Acta biomaterialia.

[19]  Michael Tanzer,et al.  Fibrous tissue ingrowth and attachment to porous tantalum. , 2000, Journal of biomedical materials research.

[20]  Vamsi Krishna Balla,et al.  Porous tantalum structures for bone implants: fabrication, mechanical and in vitro biological properties. , 2010, Acta biomaterialia.

[21]  H. M. Kim,et al.  Bonding of alkali- and heat-treated tantalum implants to bone. , 2000, Journal of biomedical materials research.

[22]  J. Black Biological performance of tantalum. , 1994, Clinical materials.

[23]  Michael Tanzer,et al.  Tissue response to porous tantalum acetabular cups: a canine model. , 1999, The Journal of arthroplasty.

[24]  Amit Bandyopadhyay,et al.  Functionally graded Co-Cr-Mo coating on Ti-6Al-4V alloy structures. , 2008, Acta biomaterialia.

[25]  C. Ohtsuki,et al.  Mechanism of bonelike apatite formation on bioactive tantalum metal in a simulated body fluid. , 2002, Biomaterials.

[26]  M. Bermúdez,et al.  Erosion–corrosion of stainless steels, titanium, tantalum and zirconium , 2005 .

[27]  D. Kohn,et al.  A parametric study of the factors affecting the fatigue strength of porous coated Ti-6A1-4V implant alloy. , 1990, Journal of biomedical materials research.

[28]  Vamsi Krishna Balla,et al.  Design and fabrication of CoCrMo alloy based novel structures for load bearing implants using laser engineered net shaping , 2010 .

[29]  R. Pilliar,et al.  The fatigue strength of porous-coated Ti-6%Al-4%V implant alloy. , 1984, Journal of biomedical materials research.

[30]  Joshua J Jacobs,et al.  Experimental and clinical performance of porous tantalum in orthopedic surgery. , 2006, Biomaterials.

[31]  Nilesh Patil,et al.  Porous tantalum in hip and knee reconstructive surgery. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.