Bone Remodelling in THA: A Comparative DXA Scan Study between Conventional Implants and a New Stemless Femoral Component. A Preliminary Report

Periprosthetic bone loss is a major cause for concern in patients undergoing total hip arthroplasty (THA). There are many different factors that may determine the pattern of bone loss and bone remodelling following THA, such as the quality of the bone before the hip replacement, skeletal bone mass at the time of the operation, material and method of fixation and implant design. Recent developments in dual-energy X-ray absorptiometry (DXA) have made it possible to quantify bone mineral density (BMD) to evaluate changes around the prosthesis and to measure bone stock and bone density redistribution after a total hip replacement. In this cross-sectional multicentre clinical study the DXA method was used to compare bone mass after uncemented THA of a custom-made stemless design with five groups of conventional cementless implants (Alloclassic, Mayo, CFP, IPS, ABG). The adaptive bone changes of the proximal femur three years after implantation were evaluated. Periprosthetic BMD was measured in 130 subjects in the seven regions of interest (ROI) based on Gruen zones. Significant differences were found between the stemless implant and the other five groups in zones 1, 4 and 7. The CFP, IPS, and ABG groups showed decreased BMD in ROI 1, and the Mayo, IPS and Alloclassic in ROI 7. An increased BMD in ROI 4 was observed in the Mayo, IPS, ABG and Alloclassic groups. The results of the present study suggest that a conservative stemless implant with complete proximal load transfer produces a homogeneous and more physiological redistribution of bone density, allowing maintenance of proximal periprosthetic bone stock.

[1]  M. Mayor,et al.  Potential errors inherent in quantitative densitometric analysis of orthopaedic radiographs. A study after total hip arthroplasty. , 1987, The Journal of bone and joint surgery. American volume.

[2]  Naoto Saito,et al.  Poor bone quality or hip structure as risk factors affecting survival of total-hip arthroplasty , 2000, The Lancet.

[3]  J. Fetto,et al.  Preservation of femoral bone mass after total hip replacements with a lateral flare stem , 2004, International Orthopaedics.

[4]  H. Amstutz,et al.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. , 1979, Clinical orthopaedics and related research.

[5]  C. Trevisan,et al.  Dual X-ray absorptiometry for the evaluation of bone density from the proximal femur after total hip arthroplasty: Analysis protocols and reproducibility , 1993, Calcified Tissue International.

[6]  C. Engh,et al.  Roentgenographic densitometry of bone adjacent to a femoral prosthesis. , 1993, Clinical orthopaedics and related research.

[7]  J. Jurvelin,et al.  Monitoring of Periprosthetic BMD After Uncemented Total Hip Arthroplasty with Dual‐Energy X‐Ray Absorptiometry—a 3‐Year Follow‐Up Study , 2001, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[8]  C. Engh,et al.  Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. , 1990, Clinical orthopaedics and related research.

[9]  L. Rosenthall,et al.  Bone densitometry: influence of prosthetic design and hydroxyapatite coating on regional adaptive bone remodelling , 1999, International Orthopaedics.

[10]  C. Engh,et al.  Factors affecting femoral bone remodeling after cementless total hip arthroplasty. , 1999, The Journal of arthroplasty.

[11]  C. Engh,et al.  The Influence of Clinical Factors on Periprosthetic Bone Remodeling , 1996, Clinical orthopaedics and related research.

[12]  J. Hua,et al.  The Effect of a Lateral Flare Feature on Uncemented Hip Stems , 1999 .

[13]  W. Harris,et al.  The contribution of the nonporous distal stem to the stability of proximally porous-coated canine femoral components. , 1993, The Journal of arthroplasty.

[14]  B. Kiratli,et al.  Determination of bone mineral density by dual X‐ray absorptiometry in patients with uncemented total hip arthroplasty , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[15]  T. Gosens,et al.  Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss , 2004, Osteoporosis International.

[16]  C. Florey,et al.  The use and interpretation of ponderal index and other weight-height ratios in epidemiological studies. , 1970, Journal of chronic diseases.

[17]  H. Hagino,et al.  Measurement of periprosthetic bone mineral density by dual-energy x-ray absorptiometry is useful for estimating fixation between the bone and the prosthesis in an early stage. , 2002, The Journal of arthroplasty.