Real-Time Virtual Measurement Technique for the Thyristor Valve Current Based on the Converter Terminal Current

The safety of converters is key to the stable operation of AC/DC hybrid power grids after AC faults. Thyristor valve current is a direct manifestation of the converter observability, but there are no measuring elements inside the converter, so the thyristor valve current can be reflected only indirectly through external electrical quantities. This paper proposes a virtual measurement scheme based on the temporal features of the converter terminal current. First, under the action of the trigger pulse, the polarity characteristics of the AC current and temporal features between the valves are utilized to predictive estimate the valve state. Then, when commutation failures occur and the bypass paths form, the conduction state of valve is constructed based on the relationship between AC and DC current. Last, when the valve is to be shut-off in the bypass path, the blocking state of the valve is corrected based on the unidirectional conductance characteristics of the valve. According to the above analysis, combined with the topological current equation of the converter, the valve current can be calculated in the whole process. Through the simulation of the different valve states and bypass paths and analysis of the field record data, the results show that the valve current can still be accurately calculated based on the virtual measurement scheme.

[1]  Arun G. Phadke,et al.  Commutation failure prediction method based on characteristic of accumulated energy in inverter , 2021 .

[2]  A. A. Padalitsa,et al.  Low-Voltage Thyristor Heterostructure for High-Current Pulse Generation at High Repetition Rate , 2021, IEEE Transactions on Electron Devices.

[3]  Ting Wang,et al.  Active Injection for Single-Ended Protection in DC Grid Using Hybrid MMC , 2021, IEEE Transactions on Power Delivery.

[4]  Xianzhong Duan,et al.  Enhanced Commutation Failure Predictive Detection Method and Control Strategy in Multi-Infeed LCC-HVDC Systems Considering Voltage Harmonics , 2021, IEEE Transactions on Power Systems.

[5]  Xiaofu Xiong,et al.  Early Warning and Inhibition of HVDC Subsequent Commutation Failure During Recovery Process Under Grid Fault , 2020, IEEE Transactions on Power Delivery.

[6]  Jun Liu,et al.  A criterion for accurate identification of commutation failure in HVDC systems , 2020 .

[7]  Xiaopeng Li,et al.  Analysis and Prevention of Subsequent Commutation Failures Caused by Improper Inverter Control Interactions in HVDC Systems , 2020, IEEE Transactions on Power Delivery.

[8]  Xinzhou Dong,et al.  An Integrated Control and Protection Scheme to Inhibit Blackouts Caused by Cascading Fault in Large-Scale Hybrid AC/DC Power Grids , 2019, IEEE Transactions on Power Electronics.

[9]  Shaahin Filizadeh,et al.  Dynamic Phasor Modeling of LCC-HVDC Systems: Unbalanced Operation and Commutation Failure , 2019, Canadian Journal of Electrical and Computer Engineering.

[10]  Peng Li,et al.  The Study and Application of Field Test Technology of UHVDC Protection System , 2019, 2019 IEEE Innovative Smart Grid Technologies - Asia (ISGT Asia).

[11]  Huan Li,et al.  A New Recovery Strategy of HVDC System During AC Faults , 2019, IEEE Transactions on Power Delivery.

[12]  Zhengyou He,et al.  A Calculation Method of Pseudo Extinction Angle for Commutation Failure Mitigation in HVDC , 2019, IEEE Transactions on Power Delivery.

[13]  Xiao-Ping Zhang,et al.  Commutation Failure Elimination of LCC HVDC Systems Using Thyristor-Based Controllable Capacitors , 2018, IEEE Transactions on Power Delivery.

[14]  K. Akshay Saha,et al.  Power losses assessments of LCC-based HVDC converter stations using datasheet parameters and IEC 61803 STD , 2018, 2018 International Conference on the Domestic Use of Energy (DUE).

[15]  Xin Li,et al.  Nelson River Pole 1 Thyristor Leakage Problem , 2018, IEEE Transactions on Power Delivery.

[16]  Zexiang CAI,et al.  Assessment of commutation failure in HVDC systems considering spatial-temporal discreteness of AC system faults , 2018 .

[17]  Lei Pang,et al.  Reverse recovery characteristics of high power thyristors in HVDC converter valve , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.

[18]  Yury S. Borovikov,et al.  A Hybrid Simulation Model for VSC HVDC , 2016, IEEE Transactions on Smart Grid.

[19]  Gengyin Li,et al.  Superposition feature of the switching functions for the dynamic phasor model of the converters under commutation failure , 2015 .

[20]  Hervé Morel,et al.  A Novel Approach to Extract the Thyristor Design Parameters for Designing of Power Electronic Systems , 2015, IEEE Transactions on Industrial Electronics.

[21]  J. Jatskevich,et al.  Dynamic Average-Value Modeling of CIGRE HVDC Benchmark System , 2014, IEEE Transactions on Power Delivery.

[22]  Anjan Bose,et al.  Modeling and Analysis of HVDC Converter by Three-Phase Dynamic Phasor , 2014, IEEE Transactions on Power Delivery.

[23]  Fang Liu,et al.  Enhancement of Commutation Reliability of an HVDC Inverter by Means of an Inductive Filtering Method , 2013, IEEE Transactions on Power Electronics.

[24]  Brett Davies,et al.  Commutation Failure Analysis in Multi-Infeed HVDC Systems , 2011, IEEE Transactions on Power Delivery.

[25]  K. Ou,et al.  Study on the Dynamic Performance of AC & DC Hybrid System in China Southern Power Grid , 2007, 2007 IEEE Power Engineering Society Conference and Exposition in Africa - PowerAfrica.

[26]  J. B. Davies,et al.  Commutation failures in HVDC transmission systems , 1996 .

[27]  D. P. Carroll,et al.  The effect of AC system frequency spectrum on commutation failure in HVDC inverters , 1990 .