Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame

In this paper, a current control scheme, based on proportional-integral regulators using sinusoidal signal integrators (SSIs), is proposed for shunt type power conditioners. The aim is to simplify the implementation of SSI-based current harmonic compensation for industrial implementations where strict limitations on the harmonic distortion of the mains' currents are required. To compensate current harmonics, the SSIs are implemented to operate both on positive and negative sequence signals. One regulator, for the fundamental current component, is implemented in the stationary reference frame. The other regulators, for the current harmonics, are all implemented in a synchronous reference frame rotating at the fundamental frequency. This allows the simultaneous compensation of two current harmonics with just one regulator, yielding a significant reduction of the computational effort compared with other current control methods employing sinusoidal signal integrators implemented in stationary reference frame. A simple and robust voltage filter is also proposed by the authors to obtain a smooth and accurate position estimation of the voltage vector at the point of common coupling (PCC) under distorted mains' voltages. The whole control algorithm has been implemented on a 16-b, fixed-point digital signal processor (DSP) platform controlling a 20-kVA power conditioner prototype. The experimental results presented in this paper for inductive and capacitive loads show the validity of the proposed solutions.

[1]  Rolf Isermann Digital Control Systems , 1981 .

[2]  Hirofumi Akagi,et al.  A study of active power filters using quad-series voltage-source PWM converters for harmonic compensation , 1990 .

[3]  Subhashish Bhattacharya,et al.  Active filter solutions for utility interface , 1995, 1995 Proceedings of the IEEE International Symposium on Industrial Electronics.

[4]  Hirofumi Akagi,et al.  New trends in active filters for power conditioning , 1996 .

[5]  Bikramjit Banerjee,et al.  Parallel active filter system implementation and design issues for utility interface of adjustable speed drive systems , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[6]  Hirofumi Akagi,et al.  The unified power quality conditioner: the integration of series- and shunt-active filters , 1998 .

[7]  Kamal Al-Haddad,et al.  A new control approach to three-phase active filter for harmonics and reactive power compensation , 1998 .

[8]  J. Svensson,et al.  Control of a voltage-source converter connected to the grid through an LCL-filter-application to active filtering , 1998, PESC 98 Record. 29th Annual IEEE Power Electronics Specialists Conference (Cat. No.98CH36196).

[9]  Paolo Mattavelli,et al.  Comparison of current control techniques for active filter applications , 1998, IEEE Trans. Ind. Electron..

[10]  Per Karlsson,et al.  Multiple Rotating Integrator Controller for Active Filters , 1999 .

[11]  M. Sonnenschein,et al.  Comparison of time‐domain and frequency‐domain control schemes for shunt active filters , 1999 .

[12]  Donald Grahame Holmes,et al.  Frequency domain analysis of three phase linear current regulators , 1999 .

[13]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady state error , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[14]  H. Stemmler,et al.  Stationary frame generalized integrators for current control of active power filters with zero steady state error for current harmonics of concern under unbalanced and distorted operation conditions , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[15]  P. Mehta,et al.  Active power filters: a review , 2000 .

[16]  R. W. De Doncker,et al.  A new hybrid filter to dampen resonances and compensate harmonic currents in industrial power systems with power factor correction equipment , 2001 .

[17]  Edison Roberto Cabral da Silva,et al.  Current control of unbalanced electrical systems , 2001, IEEE Trans. Ind. Electron..