BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET

Due to detector developments in the last decade, the time-of-flight (TOF) method is now commonly used to improve the quality of positron emission tomography (PET) images. Clinical TOF-PET systems based on L(Y)SO:Ce crystals and silicon photomultipliers (SiPMs) with coincidence resolving times (CRT) between 325 ps and 400 ps FWHM have recently been developed. Before the introduction of L(Y)SO:Ce, BGO was used in many PET systems. In addition to a lower price, BGO offers a superior attenuation coefficient and a higher photoelectric fraction than L(Y)SO:Ce. However, BGO is generally considered an inferior TOF-PET scintillator. In recent years, TOF-PET detectors based on the Cherenkov effect have been proposed. However, the low Cherenkov photon yield in the order of  ∼10 photons per event complicates energy discrimination-a severe disadvantage in clinical PET. The optical characteristics of BGO, in particular its high transparency down to 310 nm and its high refractive index of  ∼2.15, are expected to make it a good Cherenkov radiator. Here, we study the feasibility of combining event timing based on Cherenkov emission with energy discrimination based on scintillation in BGO, as a potential approach towards a cost-effective TOF-PET detector. Rise time measurements were performed using a time-correlated single photon counting (TCSPC) setup implemented on a digital photon counter (DPC) array, revealing a prompt luminescent component likely to be due to Cherenkov emission. Coincidence timing measurements were performed using BGO crystals with a cross-section of 3 mm  ×  3 mm and five different lengths between 3 mm and 20 mm, coupled to DPC arrays. Non-Gaussian coincidence spectra with a FWHM of 200 ps were obtained with the 27 mm3 BGO cubes, while FWHM values as good as 330 ps were achieved with the 20 mm long crystals. The FWHM value was found to improve with decreasing temperature, while the FWTM value showed the opposite trend.

[1]  Kan Yang,et al.  Effects of $\hbox {Ca}^{2+}$ Co-Doping on the Scintillation Properties of LSO:Ce , 2008, IEEE Transactions on Nuclear Science.

[2]  F. Beekman,et al.  LaBr3:Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time , 2010, Physics in medicine and biology.

[3]  M. V. Nemallapudi,et al.  Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca , 2015, Physics in medicine and biology.

[4]  Charles L. Melcher,et al.  A promising new scintillator: cerium-doped lutetium oxyorthosilicate , 1992 .

[5]  R. Zhu,et al.  Optical and scintillation properties of inorganic scintillators in high energy physics , 2007 .

[6]  T. Frach,et al.  The digital silicon photomultiplier — Principle of operation and intrinsic detector performance , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[7]  Joshua W Cates,et al.  Advances in coincidence time resolution for PET , 2016, Physics in medicine and biology.

[8]  Carsten Degenhardt,et al.  The digital silicon photomultiplier — System architecture and performance evaluation , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[9]  Paul Lecoq,et al.  Measurement of intrinsic rise times for various L(Y)SO and LuAG scintillators with a general study of prompt photons to achieve 10 ps in TOF-PET , 2016, Physics in medicine and biology.

[10]  Analysis of a Cylindrical Hybrid Positron Camera with Bismuth Germanate (BGO) Scintillation Crystals , 1978 .

[11]  S. Korpar,et al.  Time-of-flight measurements with Cherenkov photons produced by 511 keV photons in lead crystals , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[12]  M. J. Berger ESTAR, PSTAR, and ASTAR: Computer programs for calculating stopping-power and range tables for electrons, protons, and helium ions , 1992 .

[13]  T. Frach,et al.  Optimization of the digital Silicon Photomultiplier for Cherenkov light detection , 2012 .

[14]  Jun Zhang,et al.  Characterization of the Vereos Digital Photon Counting PET System , 2015 .

[15]  ScienceDirect,et al.  Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment , 1984 .

[16]  Alberto Gola,et al.  Bismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET , 2016, Physics in medicine and biology.

[17]  Weronika Wolszczak Depth of interaction determination with temperature gradient function in continuous bismuth germanate oxide (BGO) crystal , 2014, Bio Algorithms Med Syst..

[18]  Dennis R. Schaart,et al.  A comprehensive characterization of the time resolution of the Philips Digital Photon Counter , 2016 .

[19]  P. Dorenbos,et al.  Accurate measurements of the rise and decay times of fast scintillators with solid state photon counters , 2012, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[20]  Kenichi Watanabe,et al.  Development of TOF-PET using Cherenkov Radiation , 2006 .

[21]  L. Gruber,et al.  New Approaches for Improvement of TOF-PET , 2013, 1305.1560.

[22]  R. Zhu,et al.  Optical and Scintillation Properties of Inorganic Scintillators in High Energy Physics , 2007, IEEE Transactions on Nuclear Science.

[23]  C. Hagen,et al.  Potential applications of electron emission membranes in medicine , 2016 .

[24]  P. Lecoq,et al.  Inorganic Scintillators for Detector Systems , 2017 .

[25]  Giacomo Borghi,et al.  Probabilities of triggering and validation in a digital silicon photomultiplier , 2014 .

[26]  I. Somlai-Schweiger,et al.  CHERENCUBE: concept definition and implementation challenges of a Cherenkov-based detector block for PET. , 2015, Medical physics.

[27]  Ronald H. Huesman,et al.  Imaging Properties of a Positron Tomograph with 280 Bgo Crystals , 1981, IEEE Transactions on Nuclear Science.

[28]  William W. Moses Recent Advances and Future Advances in Time-of-Flight PET. , 2007 .

[29]  Alexander M. Grant,et al.  NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system. , 2016, Medical physics.

[30]  J. Marton,et al.  Studies on the Cherenkov Effect for Improved Time Resolution of TOF-PET , 2013, IEEE Transactions on Nuclear Science.

[31]  Rudolf Nitsche,et al.  Crystal Growth and Electro‐Optic Effect of Bismuth Germanate, Bi4 (GeO4)3 , 1965 .

[32]  W. Moses Recent Advances and Future Advances in Time-of-Flight PET. , 2006, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[33]  M. Moszynski,et al.  TIMING PROPERTIES OF BGO SCINTILLATOR , 1981 .

[34]  M. V. Nemallapudi,et al.  State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs , 2016 .

[35]  I. Adachi,et al.  Proposal of Cherenkov TOFPET with silica aerogel , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[36]  O. Nalcioglu,et al.  Analysis of a Cylindrical Hybrid Positron Camera with Bismuth Germanate (BGO) Scintillation Crystals , 1978, IEEE Transactions on Nuclear Science.

[37]  R. Dolenec,et al.  Study of TOF PET using Cherenkov light , 2011 .

[38]  Suleman Surti,et al.  Benefit of Time-of-Flight in PET: Experimental and Clinical Results , 2008, Journal of Nuclear Medicine.

[39]  J. Karp,et al.  Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[40]  Volkmar Schulz,et al.  ToF Performance Evaluation of PET Modules With Digital Silicon Photomultiplier Technology During MR Operation , 2015, IEEE Transactions on Nuclear Science.

[41]  M. Conti Focus on time-of-flight PET: the benefits of improved time resolution , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[42]  W. Moses,et al.  Fundamental limits of scintillation detector timing precision , 2014, Physics in medicine and biology.

[43]  David J. Singh,et al.  Spectroscopic refractive indices of monoclinic single crystal and ceramic lutetium oxyorthosilicate from 200 to 850 nm , 2012 .

[44]  John L. Humm,et al.  From PET detectors to PET scanners , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[45]  G. Mageras,et al.  A measurement of the light yield of common inorganic scintillators , 1988 .

[46]  W. Moses,et al.  Measurements of the intrinsic rise times of common inorganic scintillators , 1999 .

[47]  Positome II: A High Efficiency Positron Imaging Device for Dynamic Brain Studies , 1979 .

[48]  K S Lee,et al.  Optical, thermo-optic, electro-optic, and photoelastic properties of bismuth germanate (Bi(4)Ge(3)O(12)). , 1996, Applied optics.

[49]  Volkmar Schulz,et al.  Advances in digital SiPMs and their application in biomedical imaging , 2016 .

[50]  J. S. Karp,et al.  Recent developments in time-of-flight PET , 2016, EJNMMI Physics.

[51]  G. E. Thomas,et al.  Measurement of the Time Dependence of Scintillation Intensity by a Delayed‐Coincidence Method , 1961 .

[52]  P. Dorenbos,et al.  Comparative Study of Co-Doped and Non Co-Doped LSO:Ce and LYSO:Ce Scintillators for TOF-PET , 2015, IEEE Transactions on Nuclear Science.

[53]  M. Paganoni,et al.  In-depth study of single photon time resolution for the Philips digital silicon photomultiplier , 2016 .

[54]  P. Lecoq,et al.  Factors influencing time resolution of scintillators and ways to improve them , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).