Design of Class DE Inverter with Second Order Constant K Band-Pass Filter

In this paper, class DE inverter with second order constant K band-pass filter is proposed. In the proposed inverter, the band-pass filter is used instead of the resonant filter in class DE inverter presented at the previous papers. By using band-pass filter, two important results can be gotten. One is the sensitivity of the output voltage to the operating frequency is suppressed by using band-pass filter. The other is that zero voltage switching operation appears when the operating frequency is lower than the nominal frequency. Moreover, it keeps the advantage of class DE inverter with resonant filter, that is, high power conversion efficiency under high frequency operation because of class E switching. The laboratory experiments achieve 90.4% power conversion efficiency under 1.98 W output power and 1.0 MHz operation.

[1]  Mitsuhiro Matsuo,et al.  Analysis of phase-controlled resonant DC-AC inverters with class E amplifier and frequency multipliers , 1998, IEEE Trans. Ind. Electron..

[2]  Hiroo Sekiya,et al.  FM/PWM control scheme in class DE inverter , 2004, IEEE Transactions on Circuits and Systems I: Regular Papers.

[3]  Frederick H. Raab,et al.  Idealized operation of the class E tuned power amplifier , 1977 .

[4]  Hiroo Sekiya,et al.  Computation of design values for Class E amplifiers without using waveform equations , 2002 .

[5]  I.D. de Vries,et al.  Solid state class DE RF power source , 1998, IEEE International Symposium on Industrial Electronics. Proceedings. ISIE'98 (Cat. No.98TH8357).

[6]  T. Suetsugu,et al.  PWM control scheme of resonant DC/DC converter with Class DE inverter and Class E rectifier , 1996, Proceedings of Intelec'96 - International Telecommunications Energy Conference.

[7]  S.-A. El-Hamamsy,et al.  Design of high-efficiency RF Class-D power amplifier , 1994 .

[8]  Hiroo Sekiya,et al.  Exact Analysis of Class DE Amplifier with FM and PWM Control , 2003 .

[9]  Hiroo Sekiya,et al.  Computation of design values for class E amplifier without using waveform equations , 2001, Proceedings of the 44th IEEE 2001 Midwest Symposium on Circuits and Systems. MWSCAS 2001 (Cat. No.01CH37257).

[10]  Tadashi Suetsugu,et al.  Idealized operation of Class DE amplifier and frequency multipliers , 1998 .

[11]  Hiroo Sekiya,et al.  Phase control for resonant DC-DC converter with class-DE inverter and class-E rectifier , 2006, IEEE Transactions on Circuits and Systems I: Regular Papers.

[12]  Sorin Hintea,et al.  Class DE Amplifiers And Their Medical Applications , 1998, Proceedings of the 6th International Conference on Optimization of Electrical and Electronic Equipments.

[13]  Iwao Sasase,et al.  New control scheme for class DE inverter by varying driving signals , 2000, IEEE Trans. Ind. Electron..

[14]  Tadashi Suetsugu,et al.  Class DE high-efficiency tuned power amplifier , 1996 .

[15]  No Sokal,et al.  CLASS-E - NEW CLASS OF HIGH-EFFICIENCY TUNED SINGLE-ENDED SWITCHING POWER AMPLIFIERS , 1975 .

[16]  D. Howe,et al.  Design oriented analysis of fourth-order LCLC converters with capacitive output filter , 2005 .

[17]  M. Albulet An exact analysis of Class-DE amplifier at any output Q , 1999 .

[18]  Tadashi Suetsugu,et al.  New resonant DC/DC converter with Class de inverter and Class E Rectifier , 1995, J. Circuits Syst. Comput..

[19]  Hiroo Sekiya,et al.  Operation of class DE amplifier outside optimum condition , 2006, 2006 IEEE International Symposium on Circuits and Systems.

[20]  Tadashi Suetsugu,et al.  Phase-controlled Class DE inverter , 1995, Proceedings of INTELEC 95. 17th International Telecommunications Energy Conference.

[21]  D. Stone,et al.  Digital control of dual-load LCLC resonant converters , 2005, 2005 European Conference on Power Electronics and Applications.

[22]  Marian K. Kazimierczuk,et al.  Exact analysis of class E tuned power amplifier at any Q and switch duty cycle , 1987 .