Computational fluid dynamics for the assessment of upper airway response to oral appliance treatment in obstructive sleep apnea.

Mandibular advancement splints (MAS), which protrude the lower jaw during sleep, are recognized as an effective treatment for obstructive sleep apnea (OSA) through their action of enlarging the airway space and preventing upper airway collapse. However a clinical challenge remains in preselecting patients who will respond to this form of therapy. We aimed to use computational fluid dynamics (CFD) in conjunction with patient upper airway scans to understand the upper airway response to treatment. Seven OSA patients were selected based on their varied treatment response (assessed by the apnea-hypopnoea index (AHI) on overnight polysomnography). Anatomically-accurate upper airway computational models were reconstructed from magnetic resonance images with and without MAS. CFD simulations of airflow were performed at the maximum flow rate during inspiration. A physical airway model of one patient was fabricated and the CFD method was validated against the pressure profile on the physical model. The CFD analysis clearly demonstrated effects of MAS treatment on the patient's UA airflow patterns. The CFD results indicated the lowest pressure often occurs close to the soft palate and the base of the tongue. Percentage change in the square root of airway pressure gradient with MAS (Δsqrt(ΔP(Max))%) was found to have the strongest relationship with treatment response (ΔAHI%) in correlation analysis (r=0.976, p=0.000167). Changes in upper airway geometry alone did not significantly correlate with treatment response. We provide further support of CFD as a potential tool for prediction of treatment outcome with MAS in OSA patients without requiring patient specific flow rates.

[1]  P. Cistulli,et al.  Cephalometry and prediction of oral appliance treatment outcome , 2012, Sleep and Breathing.

[2]  Yohan Payan,et al.  Simulation of the Retroglossal Fluid-Structure Interaction During Obstructive Sleep Apnea , 2006, ISBMS.

[3]  Shanmugam Murugappan,et al.  Validation of computational fluid dynamics methodology used for human upper airway flow simulations. , 2009, Journal of biomechanics.

[4]  P. Cistulli,et al.  The effect of mandibular advancement on upper airway structure in obstructive sleep apnoea , 2010, Thorax.

[5]  W. De Backer,et al.  Site of upper airway obstruction in obstructive apnoea and influence of sleep stage. , 1997, The European respiratory journal.

[6]  Mihai Mihaescu,et al.  Large eddy simulation of the pharyngeal airflow associated with obstructive sleep apnea syndrome at pre and post-surgical treatment. , 2011, Journal of biomechanics.

[7]  C. Kushida,et al.  Sites of obstruction in obstructive sleep apnea. , 2002, Chest.

[8]  Jin Qian,et al.  Effect of oral appliance therapy on upper airway collapsibility in obstructive sleep apnea. , 2003, American journal of respiratory and critical care medicine.

[9]  K. Ferguson,et al.  Oral appliances for snoring and obstructive sleep apnea: a review. , 2006, Sleep.

[10]  P. G. Young,et al.  A computational fluid dynamics study of inspiratory flow in orotracheal geometries , 2007, Medical & Biological Engineering & Computing.

[11]  Ted B. Martonen,et al.  Flow simulation in the human upper respiratory tract , 2007, Cell Biochemistry and Biophysics.

[12]  P. Cistulli,et al.  Treatment of snoring and obstructive sleep apnea with mandibular repositioning appliances. , 2004, Sleep medicine reviews.

[13]  Daniel J Buysse,et al.  Sleep–Related Breathing Disorders in Adults: Recommendations for Syndrome Definition and Measurement Techniques in Clinical Research , 2000 .

[14]  P. Cistulli,et al.  A randomized, controlled study of a mandibular advancement splint for obstructive sleep apnea. , 2001, American journal of respiratory and critical care medicine.

[15]  J. Udupa,et al.  Computational fluid dynamics modeling of the upper airway of children with obstructive sleep apnea syndrome in steady flow. , 2006, Journal of biomechanics.

[16]  Florian R. Menter,et al.  Review of the shear-stress transport turbulence model experience from an industrial perspective , 2009 .

[17]  C. D'Ambrosio,et al.  Sleep-related breathing disorders and cardiovascular disease. , 2000, The American journal of medicine.

[18]  Soo-Jin Jeong,et al.  Numerical investigation on the flow characteristics and aerodynamic force of the upper airway of patient with obstructive sleep apnea using computational fluid dynamics. , 2007, Medical engineering & physics.

[19]  Andrew Pollard,et al.  Experimental measurements and computational modeling of the flow field in an idealized human oropharynx , 2003 .

[20]  W A Whitelaw,et al.  Interaction of cross-sectional area, driving pressure, and airflow of passive velopharynx. , 1997, Journal of applied physiology.

[21]  P. Cistulli,et al.  Dental appliance treatment for obstructive sleep apnea. , 2007, Chest.

[22]  P. Cistulli,et al.  Oropharyngeal collapse predicts treatment response with oral appliance therapy in obstructive sleep apnea. , 2006, Sleep.

[23]  P. Parizel,et al.  Functional imaging using computational fluid dynamics to predict treatment success of mandibular advancement devices in sleep-disordered breathing. , 2007, Journal of Biomechanics.

[24]  Raanan Arens,et al.  Noninvasive estimation of pharyngeal airway resistance and compliance in children based on volume-gated dynamic MRI and computational fluid dynamics. , 2011, Journal of applied physiology.

[25]  David D. Sampson,et al.  Measurement, Reconstruction, and Flow-Field Computation of the Human Pharynx With Application to Sleep Apnea , 2010, IEEE Transactions on Biomedical Engineering.