Seismic Protection of Frame Structures by Fluid Viscous Damped Braces

A research study on a damped bracing system incorporating pressurized silicone fluid viscous devices for seismic protection of frame structures is presented in this paper. This technology features an inverse-chevron brace configuration, where a pair of interfaced devices are placed, parallel with the floor-beam axis, at the tip end of each couple of supporting steel braces. The experimental section of this study consisted of a pseudodynamic testing campaign on a 2:3-scale three-story steel frame and a full-scale three-story reinforced concrete frame seismically retrofitted by the technology considered. Test results were elaborated to evaluate: the improvement of seismic response of both structures after retrofit, also assessed through a formal performance-based evaluation analysis; the capabilities of the assumed analytical and numerical models in reproducing the observed structural response; and the feasibility of a methodology previously formulated to select the damping coefficient of fluid viscous devices, herein implemented with further details for practical use. This methodology was applied to the design of the protection systems of the two test structures, and checked by comparing the target and experimentally obtained values of the governing energy-ratio coefficients.

[1]  M. D. Martínez-Rodrigo,et al.  An optimum retrofit strategy for moment resisting frames with nonlinear viscous dampers for seismic applications , 2003 .

[2]  Georges Magonette,et al.  Seismic tests on reinforced concrete and steel frames retrofitted with dissipative braces , 2004 .

[3]  T. T. Soong,et al.  Passive Energy Dissipation Systems in Structural Engineering , 1997 .

[4]  Stefano Sorace,et al.  Non-linear dynamic modelling and design procedure of FV spring- dampers for base isolation , 2001 .

[5]  Gloria Terenzi,et al.  Dynamics of SDOF Systems with Nonlinear Viscous Damping , 1999 .

[6]  Panos Tsopelas,et al.  TOGGLE-BRACE-DAMPER SEISMIC ENERGY DISSIPATION SYSTEMS , 2001 .

[8]  Michael C. Constantinou,et al.  Experimental study of seismic response of buildings with supplemental fluid dampers , 1993 .

[9]  Stefano Sorace,et al.  Non-linear dynamic design procedure of FV spring-dampers for base isolation — frame building applications , 2001 .

[10]  Michael C. Constantinou,et al.  Scissor-Jack-Damper Energy Dissipation System , 2003 .

[11]  T. T. Soong,et al.  Supplemental energy dissipation: state-of-the-art and state-of-the- practice , 2002 .

[12]  Michael C. Constantinou,et al.  EXPERIMENTAL AND ANALYTICAL INVESTIGATION OF SEISMIC RETROFIT OF STRUCTURES WITH SUPPLEMENTAL DAMPING: PART 1 - FLUID VISCOUS DAMPING DEVICES , 1995 .

[13]  Yl L. Xu,et al.  Optimum design of active/passive control devices for tall buildings under earthquake excitation , 2002 .

[14]  Robert D. Hanson,et al.  Seismic design with supplemental energy dissipation devices , 2001 .

[15]  Izuru Takewaki,et al.  Application of an optimum design method to practical building frames with viscous dampers and hysteretic dampers , 2003 .

[16]  Stefano Sorace,et al.  Iterative design procedure of fluid viscous devices included in braced frames , 1999 .

[17]  C. V. Anderson,et al.  The Federal Emergency Management Agency (FEMA) , 2002 .

[18]  Stuart S. Chen,et al.  The Seismic Response of a 1:3 Scale Model R.C. Structure with Elastomeric Spring Dampers , 1995 .