Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I'mRT MatriXX—a feasibility study

The 2D ionization chamber array I'mRT MatriXX (IBA, Schwarzenbruck, Germany) has been developed for absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT) for perpendicular beam incidence. The aim of this study is to evaluate the applicability of I'mRT MatriXX for oblique beam incidence and hybrid plan verification of IMRT with original gantry angles. For the assessment of angular dependence, open fields with gantry angles in steps of 10 degrees were calculated on a CT scan of I'mRT MatriXX. For hybrid plan verification, 17 clinical IMRT plans and one rotational plan were used. Calculations were performed with pencil beam (PB), collapsed cone (CC) and Monte Carlo (MC) methods, which had been previously validated. Measurements were conducted on an Elekta SynergyS linear accelerator. To assess the potential and limitations of the system, gamma evaluation was performed with different dose tolerances and distances to agreement. Hybrid plan verification passed the gamma test with 4% dose tolerance and 3 mm distance to agreement in all cases, in 82-88% of the cases for tolerances of 3%/3 mm, and in 59-76% of the cases if 3%/2 mm were used. Separate evaluation of the low dose and high dose regions showed that I'mRT MatriXX can be used for hybrid plan verification of IMRT plans within 3% dose tolerance and 3 mm distance to agreement with a relaxed dose tolerance of 4% in the low dose region outside the multileaf collimator (MLC).

[1]  D. Low,et al.  A technique for the quantitative evaluation of dose distributions. , 1998, Medical physics.

[2]  R. Mohan,et al.  Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations. , 2000, Physics in medicine and biology.

[3]  J. Dempsey,et al.  Evaluation of the gamma dose distribution comparison method. , 2003, Medical physics.

[4]  Timothy D. Solberg,et al.  Patient specific quality assurance for the delivery of intensity modulated radiotherapy , 2003, Journal of applied clinical medical physics.

[5]  Cedric X. Yu,et al.  Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee. , 2003, Medical physics.

[6]  I. Rosen,et al.  Implementing IMRT in clinical practice: a joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine. , 2004, International journal of radiation oncology, biology, physics.

[7]  R. Cirio,et al.  Dosimetric characterization of a large area pixel-segmented ionization chamber. , 2004, Medical physics.

[8]  S Giordanengo,et al.  D-IMRT verification with a 2D pixel ionization chamber: dosimetric and clinical results in head and neck cancer. , 2005, Physics in medicine and biology.

[9]  M. Stock,et al.  Interpretation and evaluation of the γ index and the γ index angle for the verification of IMRT hybrid plans , 2005 .

[10]  Lei Dong,et al.  Retrospective analysis of 2D patient-specific IMRT verifications. , 2005, Medical physics.

[11]  T. Bortfeld IMRT: a review and preview , 2006, Physics in medicine and biology.

[12]  F. Lohr,et al.  Intensity-Modulated Radiation Therapy (IMRT) with Different Combinations of Treatment-Planning Systems and Linacs , 2006, Strahlentherapie und Onkologie.

[13]  D. Albers,et al.  Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine , 2007, Physics in medicine and biology.

[14]  M. Alber,et al.  A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation , 2007, Physics in medicine and biology.

[15]  Michael Gillin,et al.  Use of a two-dimensional ionization chamber array for proton therapy beam quality assurance. , 2008, Medical physics.

[16]  Karl Otto,et al.  Volumetric modulated arc therapy: IMRT in a single gantry arc. , 2007, Medical physics.