The dicrotic notch analyzed by a numerical model

Divergent concepts on the origin of the dicrotic notch are widespread in medical literature and education. Since most medical textbooks explain the origin of the dicrotic notch as caused by the aortic valve closure itself, this is commonly transmitted in medical physiology courses. We present clinical data and numerical simulations to demonstrate that reflected pressure waves could participate as one of the causes of the dicrotic notch. Our experimental data from continuous arterial pressure measurements from adult patients undergoing vascular surgery suggest that isolated changes in peripheral vascular resistance using an intravenous bolus of phenylephrine (a selective alpha 1-receptor agonist and thus a potent vasoconstrictor) modify the dicrotic notch. We then explore the mechanisms behind this phenomenon by using a numerical model based on integrated axisymmetric Navier-Stokes equations to compute the hemodynamic flow. Our model illustrates clearly how modifications in peripheral artery resistance may result in changes in the amplitude of the dicrotic notch by modifying reflected pressure waves. We believe that this could be a useful tool in teaching medical physiology courses.

[1]  J. Staessen,et al.  Clinical applications of arterial stiffness; definitions and reference values. , 2002, American journal of hypertension.

[2]  S. Sherwin,et al.  Analysing the pattern of pulse waves in arterial networks: a time-domain study , 2009 .

[3]  R. Deane,et al.  The dynamic responses of liquid-filled catheter systems for direct measurements of blood pressure. , 1980, Anesthesiology.

[4]  Douglas P. Zipes,et al.  Braunwald's Heart Disease: A Textbook of Cardiovascular Medicine, 2-Volume Set, 10th Edition , 2011 .

[5]  D. Chemla,et al.  Relation between aortic dicrotic notch pressure and mean aortic pressure in adults. , 1995, The American journal of cardiology.

[6]  J Liebman,et al.  Intracardiac Pressure‐Sound Correlates of Echographic Aortic Valve Closure , 1977, Circulation.

[7]  Bruce A. Stanton,et al.  Berne & Levy Principles of Physiology , 2005 .

[8]  Matthias L. Riess,et al.  Arterial flow waveforms, vascular tone, and chronic fatigue: A case report , 2015, Autonomic Neuroscience.

[9]  W. Boron,et al.  Medical physiology : a cellular and molecular approach , 2002 .

[10]  N. Stergiopulos,et al.  Assessment of distributed arterial network models , 1997, Medical and Biological Engineering and Computing.

[11]  R. D. Latham,et al.  Regional wave travel and reflections along the human aorta: a study with six simultaneous micromanometric pressures. , 1985, Circulation.

[12]  Alessandra Borlotti,et al.  Experimental evaluation of local wave speed in the presence of reflected waves. , 2014, Journal of biomechanics.

[13]  S. Sherwin,et al.  Pulse wave propagation in a model human arterial network: assessment of 1-D numerical simulations against in vitro measurements. , 2007, Journal of biomechanics.

[14]  P. Libby,et al.  Braunwald's Heart Disease: A Textbook of Cardiovascular Medicine, 2-Volume Set, 9th Edition Expert Consult Premium Edition €“ Enhanced Online Features , 2011 .

[15]  A. Guyton,et al.  Textbook of Medical Physiology , 1961 .

[16]  J Liska,et al.  Left ventricular end-systolic pressure estimated from measurements in a peripheral artery. , 1991, Journal of cardiothoracic and vascular anesthesia.

[17]  G C van den Bos,et al.  Pulse Wave Reflection: Can It Explain the Differences Between Systemic and Pulmonary Pressure and Flow Waves? A Study in Dogs , 1982, Circulation research.

[18]  Ashraf W. Khir,et al.  Measurements of wave speed and reflected waves in elastic tubes and bifurcations , 2002 .

[19]  N. Westerhof,et al.  Forward and backward waves in the arterial system. , 1972, Cardiovascular research.

[20]  R. Mates,et al.  Analysis and Correction of Pressure Wave Distortion in Fluid‐Filled Catheter Systems , 1974, Circulation.

[21]  Douglas L. Mann,et al.  Braunwald’s Heart Disease: A Textbook of Cardiovascular Medicine. 8th edition , 2018 .

[22]  Y Imai,et al.  Regulation of the aortic valve opening. In vivo dynamic measurement of aortic valve orifice area. , 1995, The Journal of thoracic and cardiovascular surgery.

[23]  P. Nithiarasu,et al.  A 1D arterial blood flow model incorporating ventricular pressure, aortic valve and regional coronary flow using the locally conservative Galerkin (LCG) method , 2008 .

[24]  Y Lecarpentier,et al.  Matching dicrotic notch and mean pulmonary artery pressures: implications for effective arterial elastance. , 1996, The American journal of physiology.

[25]  A P Avolio,et al.  Pulsatile Flow and Pressure in Human Systemic Arteries: Studies in Man and in a Multibranched Model of the Human Systemic Arterial Tree , 1980, Circulation research.

[26]  B. Westerhof,et al.  Quantification of Wave Reflection in the Human Aorta From Pressure Alone: A Proof of Principle , 2006, Hypertension.

[27]  S. Sherwin,et al.  Pulse wave propagation in a model human arterial network: Assessment of 1-D visco-elastic simulations against in vitro measurements , 2011, Journal of biomechanics.

[28]  Pierre-Yves Lagrée,et al.  Verification and comparison of four numerical schemes for a 1D viscoelastic blood flow model , 2013, Computer methods in biomechanics and biomedical engineering.

[29]  R. Reneman,et al.  The dicrotic notch as alternative time-reference point to measure local pulse wave velocity in the carotid artery by means of ultrasonography , 2009, Journal of hypertension.

[30]  Koen D Reesink,et al.  Noninvasive Assessment of Arterial Stiffness Should Discriminate Between Systolic and Diastolic Pressure Ranges , 2010, Hypertension.

[31]  N. Westerhof,et al.  Aortic Input Impedance in Normal Man: Relationship to Pressure Wave Forms , 1980, Circulation.

[32]  Gianluigi Rozza,et al.  Modeling of physiological flows , 2012 .

[33]  Y. Fung,et al.  Mechanics of the Circulation , 2011, Developments in Cardiovascular Medicine.

[34]  Michael R. Pinsky,et al.  Applied physiology in intensive care medicine , 2006 .