Extraction of Temporal Gait Parameters using a Reduced Number of Wearable Accelerometers

Wearable inertial systems often require many sensing units in order to reach an accurate extraction of temporal gait parameters. Reconciling easy and fast handling in daily clinical use and accurate extraction of a substantial number of relevant gait parameters is a challenge. This paper describes the implementation of a new accelerometer-based method that accurately and precisely detects gait events/parameters from acceleration signals measured from only two accelerometers attached on the heels of the subject’s usual shoes. The first step of the proposed method uses a gait segmentation based on the continuous wavelet transform (CWT) that provides only a rough estimation of motionless periods defining relevant local acceleration signals. The second step uses the CWT and a novel piecewise-linear fitting technique to accurately extract, from these local acceleration signals, gait events, each labelled as heel strike (HS), toe strike (TS), heel-off (HO), toe-off (TO), or heel clearance (HC). A stride-by-stride validation of these extracted gait events was carried out by comparing the results with reference data provided by a kinematic 3D analysis system (used as gold standard) and a video camera. The temporal accuracy ± precision of the gait events were for HS: 7.2 ms ± 22.1 ms, TS: 0.7 ms ± 19.0 ms, HO: −3.4 ms ± 27.4 ms, TO: 2.2 ms ± 15.7 ms, and HC: 3.2 ms ± 17.9 ms. In addition, the occurrence times of right/left stance, swing, and stride phases were estimated with a mean error of −6 ms ± 15 ms, −5 ms ± 17 ms, and −6 ms ± 17 ms, respectively. The accuracy and precision achieved by the extraction algorithm for healthy subjects, the simplification of the hardware (through the reduction of the number of accelerometer units required), and the validation results obtained, convince us that the proposed accelerometer-based system could be extended for assessing pathological gait (e.g., for patients with Parkinson’s disease).

[1]  J. Verly,et al.  Development and validation of an accelerometer-based method for quantifying gait events. , 2015, Medical engineering & physics.

[2]  K. Aminian,et al.  Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty , 1999, Medical & Biological Engineering & Computing.

[3]  Cédric Schwartz,et al.  Development and validation of a 3D kinematic-based method for determining gait events during overground walking , 2014, 2014 International Conference on 3D Imaging (IC3D).

[4]  Michael W. Whittle,et al.  Clinical gait analysis: A review , 1996 .

[5]  Björn Eskofier,et al.  Inertial Sensor-Based Stride Parameter Calculation From Gait Sequences in Geriatric Patients , 2015, IEEE Transactions on Biomedical Engineering.

[6]  Olivier Bruls,et al.  Gait segmentation using continuous wavelet transform for extracting validated gait events from accelerometer signals , 2015 .

[7]  Nicholas Wickström,et al.  Identification of Gait Events using Expert Knowledge and Continuous Wavelet Transform Analysis , 2014, BIOSIGNALS.

[8]  H.B.K. Boom,et al.  Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation , 1990, IEEE Transactions on Biomedical Engineering.

[9]  Pia M. Forsman,et al.  Wavelet analysis to detect gait events , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  Jan Rueterbories,et al.  Methods for gait event detection and analysis in ambulatory systems. , 2010, Medical engineering & physics.

[11]  G. ÓLaighin,et al.  Direct measurement of human movement by accelerometry. , 2008, Medical engineering & physics.

[12]  Benoit M. Macq,et al.  Gait feature extraction in Parkinson's disease using low-cost accelerometers , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  H.J. Stam,et al.  Automated estimation of initial and terminal contact timing using accelerometers; development and validation in transtibial amputees and controls , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  Bernard Auvinet,et al.  Analyse de la marche humaine dans la pratique hospitalière par une méthode accélérométrique , 1999 .

[15]  Sang-Hyun Cho,et al.  Wearable Accelerometer System for Measuring the Temporal Parameters of Gait , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  Catherine Dehollain,et al.  Gait assessment in Parkinson's disease: toward an ambulatory system for long-term monitoring , 2004, IEEE Transactions on Biomedical Engineering.