Distributed source modeling of intracranial stereoelectro-encephalographic measurements

Intracranial stereoelectroencephalography (sEEG) provides unsurpassed sensitivity and specificity for human neurophysiology. However, functional mapping of brain functions has been limited because the implantations have sparse coverage and differ greatly across individuals. Here, we developed a distributed, anatomically realistic sEEG source-modeling approach for within- and between-subject analyses. In addition to intracranial event-related potentials (iERP), we estimated the sources of high broadband gamma activity (HBBG), a putative correlate of local neural firing. Our novel approach accounted for a significant portion of the variance of the sEEG measurements in leave-one-out cross-validation. After logarithmic transformations, the sensitivity and signal-to-noise ratio were linearly inversely related to the minimal distance between the brain location and electrode contacts (slope≈-3.6). The signa-to-noise ratio and sensitivity in the thalamus and brain stem were comparable to those locations at the vicinity of electrode contact implantation. The HGGB source estimates were remarkably consistent with analyses of intracranial-contact data. In conclusion, distributed sEEG source modeling provides a powerful neuroimaging tool, which facilitates anatomically-normalized functional mapping of human brain using both iERP and HBBG data.

[1]  Radu Ranta,et al.  Evaluating dipolar source localization feasibility from intracerebral SEEG recordings , 2014, NeuroImage.

[2]  Fabrice Wendling,et al.  Defining epileptogenic networks: Contribution of SEEG and signal analysis , 2017, Epilepsia.

[3]  Gene H. Golub,et al.  Generalized cross-validation as a method for choosing a good ridge parameter , 1979, Milestones in Matrix Computation.

[4]  Carlos H. Muravchik,et al.  iElectrodes: A Comprehensive Open-Source Toolbox for Depth and Subdural Grid Electrode Localization , 2017, Front. Neuroinform..

[5]  Naotaka Fujii,et al.  EECoG-Comp: An Open Source Platform for Concurrent EEG/ECoG Comparisons—Applications to Connectivity Studies , 2018, Brain Topography.

[6]  E. Somersalo,et al.  Visualization of Magnetoencephalographic Data Using Minimum Current Estimates , 1999, NeuroImage.

[7]  Georgia Ramantani,et al.  Catching the Invisible: Mesial Temporal Source Contribution to Simultaneous EEG and SEEG Recordings , 2014, Brain Topography.

[8]  Jorge Gonzalez-Martinez,et al.  Stereotactic placement of depth electrodes in medically intractable epilepsy. , 2014, Journal of neurosurgery.

[9]  Dana Boatman-Reich,et al.  Cortical high-gamma responses in auditory processing. , 2011, American journal of audiology.

[10]  Radu Ranta,et al.  Dipolar source localization from intracerebral SEEG recordings , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[11]  M. Andermann,et al.  Short-term plasticity as a neural mechanism supporting memory and attentional functions , 2011, Brain Research.

[12]  J. Hua,et al.  Intracranial EEG analysis in tumor-related epilepsy: Evidence of distant epileptic abnormalities , 2016, Clinical Neurophysiology.

[13]  André J. W. van der Kouwe,et al.  Brain morphometry with multiecho MPRAGE , 2008, NeuroImage.

[14]  Blaise Yvert,et al.  Localization of human supratemporal auditory areas from intracerebral auditory evoked potentials using distributed source models , 2005, NeuroImage.

[15]  R. Ilmoniemi,et al.  Interpreting magnetic fields of the brain: minimum norm estimates , 2006, Medical and Biological Engineering and Computing.

[16]  Gultekin Gulsen,et al.  Amygdala-hippocampal dynamics during salient information processing , 2017, Nature Communications.

[17]  J. Maunsell,et al.  Different Origins of Gamma Rhythm and High-Gamma Activity in Macaque Visual Cortex , 2011, PLoS biology.

[18]  Bruno Rossion,et al.  A face-selective ventral occipito-temporal map of the human brain with intracerebral potentials , 2016, Proceedings of the National Academy of Sciences.

[19]  Robert Oostenveld,et al.  Integrated analysis of anatomical and electrophysiological human intracranial data , 2017, Nature Protocols.

[20]  Lauri Parkkonen,et al.  Potential of on-scalp MEG: Robust detection of human visual gamma-band responses , 2019, bioRxiv.

[21]  M. O’Donnell,et al.  NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. , 1985, Medical physics.

[22]  J. Belliveau,et al.  Short-term plasticity in auditory cognition , 2007, Trends in Neurosciences.

[23]  Juan Bulacio,et al.  The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients. , 2014, Journal of neurosurgery.

[24]  Gabriele Arnulfo,et al.  SEEG assistant: a 3DSlicer extension to support epilepsy surgery , 2017, BMC Bioinformatics.

[25]  Josef Parvizi,et al.  Promises and limitations of human intracranial electroencephalography , 2018, Nature Neuroscience.

[26]  A. Dale,et al.  Distributed current estimates using cortical orientation constraints , 2006, Human brain mapping.

[27]  Giancarlo Ferrigno,et al.  Automatic Trajectory Planner for StereoElectroEncephaloGraphy Procedures: A Retrospective Study , 2013, IEEE Transactions on Biomedical Engineering.

[28]  Georgia Ramantani,et al.  Electrical source imaging in cortical malformation–related epilepsy: A prospective EEG‐SEEG concordance study , 2014, Epilepsia.

[29]  Xavier Tricoche,et al.  Influence of tissue conductivity anisotropy on EEG/MEG field and return current computation in a realistic head model: A simulation and visualization study using high-resolution finite element modeling , 2006, NeuroImage.

[30]  Andrew J. Watrous,et al.  Theta and Alpha Oscillations Are Traveling Waves in the Human Neocortex , 2017, Neuron.

[31]  Liberty S. Hamilton,et al.  Intonational speech prosody encoding in the human auditory cortex , 2017, Science.

[32]  Yoshio Okada,et al.  Boundary Element Fast Multipole Method for Enhanced Modeling of Neurophysiological Recordings , 2020, IEEE Transactions on Biomedical Engineering.

[33]  C. Koch,et al.  The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes , 2012, Nature Reviews Neuroscience.

[34]  A. Dale,et al.  High‐resolution intersubject averaging and a coordinate system for the cortical surface , 1999, Human brain mapping.

[35]  Jack J. Lin,et al.  Direct brain recordings reveal hippocampal rhythm underpinnings of language processing , 2016, Proceedings of the National Academy of Sciences.

[36]  L. Koessler,et al.  SEEG dipole source localization based on an empirical Bayesian approach taking into account forward model uncertainties , 2017, NeuroImage.

[37]  Gabriele Arnulfo,et al.  Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures. , 2013, Neurosurgery.

[38]  E. Halgren,et al.  Dynamic Statistical Parametric Mapping Combining fMRI and MEG for High-Resolution Imaging of Cortical Activity , 2000, Neuron.

[39]  P. Hansen Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion , 1987 .

[40]  Théodore Papadopoulo,et al.  OpenMEEG: opensource software for quasistatic bioelectromagnetics , 2010, Biomedical engineering online.

[41]  Jeremy R. Manning,et al.  Broadband Shifts in Local Field Potential Power Spectra Are Correlated with Single-Neuron Spiking in Humans , 2009, The Journal of Neuroscience.

[42]  K. Miller Broadband Spectral Change: Evidence for a Macroscale Correlate of Population Firing Rate? , 2010, The Journal of Neuroscience.

[43]  Bin He,et al.  Electromagnetic source imaging using simultaneous scalp EEG and intracranial EEG: An emerging tool for interacting with pathological brain networks , 2018, Clinical Neurophysiology.

[44]  Richard M. Leahy,et al.  Electromagnetic brain mapping , 2001, IEEE Signal Process. Mag..

[45]  Andreas Schulze-Bonhage,et al.  Source reconstruction based on subdural EEG recordings adds to the presurgical evaluation in refractory frontal lobe epilepsy , 2013, Clinical Neurophysiology.

[46]  L. Vaina,et al.  Mapping the signal‐to‐noise‐ratios of cortical sources in magnetoencephalography and electroencephalography , 2009, Human brain mapping.

[47]  Andreas Schulze-Bonhage,et al.  Decoding natural grasp types from human ECoG , 2012, NeuroImage.

[48]  M. Piana,et al.  Source modeling of ElectroCorticoGraphy (ECoG) data: Stability analysis and spatial filtering , 2016, Journal of Neuroscience Methods.

[49]  P. Grant,et al.  Ictal and interictal source imaging on intracranial EEG predicts epilepsy surgery outcome in children with focal cortical dysplasia , 2020, Clinical Neurophysiology.

[50]  Lauri Parkkonen,et al.  Potential of on‐scalp MEG: Robust detection of human visual gamma‐band responses , 2019, Human brain mapping.

[51]  Bruno Rossion,et al.  Right hemispheric dominance of visual phenomena evoked by intracerebral stimulation of the human visual cortex , 2014, Human brain mapping.

[52]  Olivier D. Faugeras,et al.  A common formalism for the Integral formulations of the forward EEG problem , 2005, IEEE Transactions on Medical Imaging.