Low-voltage-ride-through control of a modular multilevel SDBC inverter for utility-scale photovoltaic systems

This paper presents theoretical and experimental discussions on low-voltage-ride-through (LVRT) operation of a modular multilevel single-delta bridge-cell (SDBC) inverter intended for utility-scale photovoltaic (PV) systems. As the penetration of distributed generation from renewable energy sources connected to medium- and high-voltage grids increases, grid-tied inverters progressively need to abide to stricter grid codes, which demand measures to maintain reliability of the grid. The latest grid codes require inverters in generation systems to provide dynamic grid support in the event of grid faults by injection of a reactive current. This paper discusses two unique solutions for an SDBC inverter to enable dynamic grid support. One method is to inject a zero-sequence current through feedforward control within the inverter, and the other is by utilizing power from the distributed dc-dc converters. No negative-sequence current is injected into the grid in both cases. This paper also highlights the issue of voltage-sag transformation through delta-wye transformers and its effect on the LVRT capability of the SDBC inverter. Experimental results on a three-phase 12.6-kVA system prove that the SDBC inverter is capable of seamlessly operating through symmetric and asymmetric voltage sags.

[1]  J. Rodriguez,et al.  Cascaded H-bridge multilevel converter multistring topology for large scale photovoltaic systems , 2011, 2011 IEEE International Symposium on Industrial Electronics.

[2]  Huai Wang,et al.  Wide-Scale Adoption of Photovoltaic Energy: Grid Code Modifications Are Explored in the Distribution Grid , 2015, IEEE Industry Applications Magazine.

[3]  Po-Tai Cheng,et al.  The Delta-Connected Cascaded H-Bridge Converter Application in Distributed Energy Resources and Fault Ride Through Capability Analysis , 2017, IEEE Transactions on Industry Applications.

[4]  Hirofumi Akagi,et al.  Enhancement of Performance, Availability, and Flexibility of a Battery Energy Storage System Based on a Modular Multilevel Cascaded Converter (MMCC-SSBC) , 2016, IEEE Transactions on Power Electronics.

[5]  Makoto Hagiwara,et al.  Negative-Sequence Reactive-Power Control by a PWM STATCOM Based on a Modular Multilevel Cascade Converter (MMCC-SDBC) , 2012 .

[6]  Hirofumi Akagi,et al.  Theoretical Comparison in Energy-Balancing Capability Between Star- and Delta-Configured Modular Multilevel Cascade Inverters for Utility-Scale Photovoltaic Systems , 2016, IEEE Transactions on Power Electronics.

[7]  Hirofumi Akagi,et al.  A Phase-Shifted PWM D-STATCOM Using a Modular Multilevel Cascade Converter (SSBC)—Part II: Zero-Voltage-Ride-Through Capability , 2015, IEEE Transactions on Industry Applications.

[8]  H. Akagi,et al.  Negative-sequence reactive-power control by a PWM STATCOM based on a modular multilevel cascade converter (MMCC-SDBC) , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[9]  Massimo Bongiorno,et al.  Investigation of Negative-Sequence Injection Capability of Cascaded H-Bridge Converters in Star and Delta Configuration , 2017, IEEE Transactions on Power Electronics.

[10]  Hirofumi Akagi,et al.  Theoretical and Experimental Comparison Between Phase-Shifted PWM and Level-Shifted PWM in a Modular Multilevel SDBC Inverter for Utility-Scale Photovoltaic Applications , 2017, IEEE Transactions on Industry Applications.

[11]  Hirofumi Akagi,et al.  Classification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC) , 2010, IEEE Transactions on Power Electronics.

[12]  Po-Tai Cheng,et al.  Zero-sequence voltage injection for DC capacitor voltage balancing control of the star-connected cascaded H-bridge PWM converter under unbalanced grid , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[13]  Georgios Konstantinou,et al.  Power Balance of Cascaded H-Bridge Multilevel Converters for Large-Scale Photovoltaic Integration , 2016, IEEE Transactions on Power Electronics.

[14]  Geert Deconinck,et al.  Enhanced Dynamic Voltage Control of Type 4 Wind Turbines During Unbalanced Grid Faults , 2015, IEEE Transactions on Energy Conversion.